background image

MONITOR 17

MONITOR 25

MONITOR 29

MONITOR 30

MONITOR 28

MONITOR 27

MONITOR 31

MONITOR 32

MONITOR 26

MONITOR 23

MONITOR 24

MONITOR 22

MONITOR 21

MONITOR 20

MONITOR 19

MONITOR 18

Page 04

If you have Door Station B, the monitors connected to the

second button must be set with the following Dip Switches:

Door Station E and F - Settings

Instructions:

* Use " * " to cancel, and "#" to confirm.

* You should press "#” to confirm after inputting the code numb er 

each time, otherwise, the set up will be cancelled automatically in 10 

seconds.

*. Input the master code to switch the setting mode, and input  the 

corresponding setting code to perform the function. After setting has 

been saved, input the next setting code to continue the set up.  Press 

" * " at any time to exit the setting mode.

* Each setting is indicated by the lighting of the LED indicators on the 

right side of the unit, and by the sound of the buzzer.

* When the registered code has been input on the keypad, the LED 

indicator (Group 1: red, group 2: blue) lights up, the buzzer s ounds, 

and the door strike/magnetic lock is unlocked.

*User Group 1 codes are linked to the first lock, and User Group 2 

codes are linked to the second lock.

* If you make a mistake when inputting the user code, press “#” to 

cancel and input the user code again.

* If 10 continuous incorrect access codes are attempted, the release 

function will be disabled for 60 seconds, the LED lights will stay on for 

60 seconds, and the door station will beep 8 times.

SETTINGS

SETTING RANGE 

DEFAULT

SETTING

CODE

1

Reset all settings 

1,2,3,4

-

00

2

Setting the master code 

1 – 12 digits 

Valid keys: 0 - 9 

1, 2, 3, 4

01

3

Setting the lighting time 

10 to 99 seconds 

10

seconds

02

4

Setting the unlock time 

1 – 99 seconds 

1 second

03

5

Setting the unlock mode 

0: Open 

1: Closed 

Open

04

6

Keypad tone settings 

0: On 

1: Off 

On

05

7

Reset code settings 

1, 2, 3, 4 

-

06

8

*and # settings 

0: Normal 

1: Reverse 

Normal

07

9

Call tone settings 

0: Enable 

1: Disable 

Enable 

08

10

Interference resistant grade 

settings

Valid Keys: 0 - 5 

2

09

12

Setting the code for 

Temporary 1 

1 – 12 digits 

Valid Keys: 0 - 9 

-

18

13

Setting the code for 

Temporary 2 

1 – 12 digits 

Valid Keys: 0 - 9 

-

19

14

Setting the code for 

 User Group 1 

1 – 12 digits 

Number of codes: 40

Valid Keys: 0 - 9 

-

20 – 59 

15

Setting the code for 

User Group 2 

1 – 12 digits 

Number of codes: 40

Valid Keys: 0 - 9 

-

60 - 99 

 

Reviews: