•  Lock Power supply :  12 Vdc, 300 mA (Internal Power)

•  Power Consumption :  2 W in standby, 8 W in working

•  NO, COM dry contact :  Max. 48 Vdc 1.5 A

•  Camera angle :  Max. 72º

•  Number of relay circuits :  2

•  Mounting :  Surface mounting

•  Dimension :  176(H) X 90(L) X 23(D) mm

•  Working temperature :  -10ºC ~ 45ºC

10. Specifications

NAME

DISCRIPTION

USAGE

PS5-24V

PS4-24V

Power supply, 85 ~ 260 Vac input,

24 Vdc / 3A output, 10 DIN modules

Connect to multi doorstations or

multi monitors (up to 2 or above)

Power supply, 85 ~ 260 Vac input, 24Vdc /

1A output, for basic kit only, 4 DIN modules

Connect to one doorstation and one

monitor(DT16 can be connected two)

-18-

Summary of Contents for 13507

Page 1: ...2 3 1 4 5 6 9 8 0 7 2 3 The design and specifications can be changed without notice to users Copyright of this manual is reserved VIDEO DOOR PHONE SYSTEM USER MANUAL English Item No 13507 13508 Versi...

Page 2: ...or Lock Controlled with Internal Power 6 4 3 2 Door Lock Controlled with Dry Contact 6 4 3 3 Unlock parameter setting set in monitor 7 4 4 Multi Door Stations Connection 8 4 5 Multi Monitors Connectio...

Page 3: ...ttach the panel to the rainy guard Use the screwdriver and the screw to x the panel Connect the cable correctly and adjust camera to the right angle Adjust camera angle 1 2 4 3 Drill holes in the wall...

Page 4: ...ower positive power S1 S2 Lock power output to connect 2 locks S Lock power output connect to the power input of locks only when using the camera to power the locks if using the external power supply...

Page 5: ...r Lock Controlled by Internal Power Connect one lock Jumper position in 1 2 1 2 3 EB LOCK BUS PL S1 S2 S Normally closed Connect two lock Jumper position in 1 2 EB LOCK LOCK 2nd 1ST 2nd EB 1ST 1 2 3 B...

Page 6: ...N 1 2 3 4 ON 1 2 3 4 ON ID 00 ID 10 ID 01 ID 11 2 Camera 3 Camera 4 Camera Basic IN OUT Wiring Mode Code 0 DIP 6 off Code 14 DIP 6 off Code 15 DIP 6 on 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON mon...

Page 7: ...te Setting Bit state Setting 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON The monitor is not at the end of the bus The monitor is at the end of the bus BIT STATE USER CODE BIT STATE USER CODE BIT STATE USER CODE Cod...

Page 8: ...Beep Beep Inputting of new master code ex 4321 1 12 digits 4 3 2 1 RED ON BLUE OFF Beep Beep Inputting of code 1 2 3 4 RED ON BLUE OFF Beep Beep All settings will be restored to their default value W...

Page 9: ...t the setting code 06 RED ON BLUE ON Beep Beep Input the setting code 07 RED ON BLUE ON Beep Beep When the cancel key is pressed the LED lights o the buzzer beeps and the system exits the setting mode...

Page 10: ...Beep Input the setting code ex 60 60 RED ON BLUE ON Beep Beep When the cancel key is pressed the LED lights o the buzzer beeps and the system exits the setting mode When there isn t any operation in...

Page 11: ...e refer service only to a trained and quali ed professional 8 Power Supply Instructions 9 Precaustions Lock Power supply 12 Vdc 300 mA Internal Power Power Consumption 2 W in standby 8 W in working NO...

Reviews: