-4-
-
+
AC~
monitor
DPS
PS4
Y
•
Single
Mode: that means the door
only has one
can only call the monitor with
it's code among 00~15.please refer to 5.2.
•
Double
Mode:that means the door
has two
A
can call the adress 00~15
of the monitor
r.please refer to 5.2.
1. Single
set the DIP swiches of Bit 3 on door station to 'on' state (refer to 5.1), single
2. Double
.set the DIP swiches of Bit 3 on door
to 'o
ff
' state (refer to 5.1),double
-5-
4.2.1 Door Lock Controlled by Internal Power
Note:
1. Only available to power on the unlock type os electoric lock.
2. The door lock is limited to 12V, and holding current must be less than 250mA.
3.
4. The Unlock Mode Parameter of Monitor must be set to 0 (by default).
4.2.2 Door Lock Controlled with Dry Contact
Note:
1. The external power supply must be used according to the lock.
2. The inside relay contact is restricted to AC or DC 24V/3A.
3. The jumper must be taken o
ff
4. Setup the Unlock Mode of Monitor for di
ff
erent lock types.
•
Power-on-to-unlock type:Unlock Mode=0 (by default)
•
Power-o
ff
-to-unlock type:Unlock Mode=1
+12V LK - (GND)
LK+(COM)
N.O.
EB+
EB -
L1
T/R -
T/R+
RS-485
JP-LK
BUS
L2
Connect to DPS
1
2
3
LOCK
EB
Jumper posi on in 1-2
+12V LK - (GND)
LK+(COM)
N.O.
EB+
EB -
L1
T/R -
T/R+
RS-485
JP-LK
BUS
L2
Connect to DPS
1
2
3
LOCK
Take o
ff
the Jum
cut the red wire
per
POWER
SUPPLY