Overall Schematic
(Using ENT07101 Rev 3)
16 x 2 LCD Module
for Trade Clock Setting
Prog Right
UP
SN SB DO CA
Door ‘B’
Connections
Door ‘A’ Connections
R
G59 t
o
Camer
a
R
G59 t
o
Camer
a
2 AMP
Delay
500mA
Fast Blow
Handset Fuses 500mA Fast Blow
500mA
Fast Blow
500mA
Fast Blow
500mA
Fast Blow
500mA
Fast Blow
500mA
Fast Blow
500mA
Fast Blow
500mA
Fast Blow
2 AMP
Delay
3.15 AMP
Delay
12V
0V
PL1
PL2
PL3
PL4
PL5
PL6
PL8
PL12
PL21
PL25
PL29
PL30
PL31
PL32
PL28
PL24
PL22
PL20
PL18
PL16
PL15
PL13
PL11
PL10
PL17
V+
V-
0v
ETC
PL19
PL23
Speech
Time
Callup
Time
Call Tone
Time
Reassurance
Volume
Door A
Lock Timer
Door B
Lock Timer
Common Bus
PL7
PL14
DR
VT
0V
BZ
S2
S1
DS
V-
V+
DR
VT
0V
BZ
S2
S1
DS
FS1
FS11
Re-Assurance LED’s
Showing system status
Video Adj.
Trade Clock Link
Remove if using
external timer
PL7
Anti-tailgating
Link.
Remove
to use ATG
connection.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
S
C
+6V
0V
S1
S2
12V
NC
NO
C
NC
NO
C
FS
PE
AT
PL33
PL27
SN SB DO CA
SN SB DO CA
BN
BE
Fit 1A
In-Line
Fuse if
SBD
2
1.5mm Flex
SN SB DO CA
Fit 1A
In-Line
Fuse if
SBD
9
10
11
12
13
14
15
16
S
C
+6V
0V
S1
S2
12V
NC
NO
C
NC
NO
C
FS
PE
AT
1
2
3
4
5
6
7
8
CALL
CALL
CALL
CALL
CALL
CALL
CALL
FUSED
FUSED
FUSED
FUSED
FUSED
FUSED
FUSED
FUSED
Phone 9
Phone 10
Phone 11
Phone 12
Phone 13
Phone 14
Phone 15
Phone 16
DR
VT
0V
BZ
S2
S1
DS
V-
V+
CB
X
CALL
V- V+
Example of typical Elite controller layout.
Parts and models may vary.
Power
to Door
Panel LCD
Power
to Door
Panel LCD
Button
Returns
Button
Returns
2
0.75mm
Spare Volt
free conntacts
Spare Volt
free contacts
PL27
Anti-tailgating
Link.
Remove
to use ATG
connection.
From PSU
Typical Installation Layout
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
S
C
+6V
0V
S1
S2
12V
NC
NO
C
NC
NO
C
FS
PE
AT
PL1
PL2
PL3
PL4
PL5
PL6
SN SB DO CA
PL12
Please Note:-
FS is a none timed
input and is suitable
for Latching Fire
switches such as the
MEM type lever fire
switch.
NO
NO
NC
NC
Fire
Switch
Push to
Exit
Magnetic or Fail
Open Release
1N4007
Diode
Fail Secure Lock
Connection
Spare
Contacts
NC
NO
To PL24 DS on common bus terminal
PL24
Common Bus
DR
VT
0V
BZ
S2
S1
DS
Note:-
Magnetic lock door contacts
CANNOT
be used for ATG
function as these locks
usually monitor power to the
lock and not door status
See Note A
Note A:
Please note if system
is to conform to Secured By
Design standards then a 1A
in-line fuse
MUST
be fitted here.
Lock & trigger wires
CANNOT
be routed via the door panel.
Trades
Mic
2
1.5mm Flex
BN
BE
Separate Door Contacts
THIS WIRE REQUIRED
IF USING EASITAG
Omit these connections
if Easicall panel fitted
2
0.75mm
flex
Note: It is preferable to use 1 x multi-core
to the door panel rather than multiple
smaller multi-cores (e.g. 3 x Cat5e’s) as
using multiple multi-cores can lead to
confusion as e.g. 3 x each colour. If using
multiple multi-cores then these should be
clearly identified at each end.
24LC16B
IC2
C
Door Panel
Buttons (NO)
Page 6
Page 7
Terminal Identifier:
PL1, 2, 29 & 30 -
Button returns/call lines 1 to 16 for doors A & B. 5VDC idle, 0v when button pressed.
PL3 & 31 (S) -
Service/Trades (S) button returns for doors A & B. 5VDC idle, 0v when button pressed.
PL3 & 31 (C) -
Button common = 0v.
PL4 & 32 -
Speaker amp connections for doors A & B. +6 = 6 VDC for legacy systems, 0v, S1 = panel microphone, S2 = panel speaker.
PL6 & 28 (12v) -
12 volts DC supply to locks fused by FS1 & FS11. Use 1.5mm2 flex
PL6 & 28 (NC) -
Normally Closed switched 0v for fail open releases. Use 1.5mm2 flex
PL6 & 28 (NO) -
Normally Open switched 0v for fail locked releases. Use 1.5mm2 flex
PL6 & 28 (C, NC & NO) -
Volt free spare contacts to trigger automatic doors etc.
PL5 & 33 (C) -
0v common for external lock triggers.
PL5 & 33 (FS) -
Non timed fire switch input (for timed input when using Drop key switches use PE). 5VDC idle, 0v to activate.
PL5 & 33 (PE) -
Timed lock release trigger for push to exits, drop key fire switches and access controllers. 5VDC idle, 0v to activate.
PL5 & 33 (AT) -
Anti tail gating. Requires normally open going closed door monitor contacts. 0v idle, 5VDC when door opened.
PL14 -
Service/Trades time-clock link. Remove if using external time-clock.
PL17 -
12 to 14 volt DC power supply input.
PL19 -
Twisted pair video output to expansion PCB's etc.
PL23 -
External service/trades time clock input. Note: remove PL14 to disable internal time clock.
PL24 -
Common bus to remote marshaling PCB's. DR = Door Release, VT = 12 volt DC supply, 0v = 0v, BZ = buzz tone, S2 = mic input
from handset, S1 = speaker input to handset, DS = Door Status for door open LED on handset.
PL10, 11, 13, 15, 16, 18, 19, 20 & 22 -
Phone ports for first 8 handsets. See Page 9 for handset connections.
PL8 & 25 -
BNC Video inputs from cameras.
PL12 & 21 -
LCD connections to door panel. SN = Speak Now, SB = System Busy, DO = Door Open & CA = Call Accept.
NOTE:
For CW1308 or Cat5e cables, use the BT Colour Code (see Page 4). It is advisable to link all spare cores to 0v.