ADVANCED FEATURES
Multi-weld Operations
183 |
P a g e
Copyright © 2021 BF ENTRON and/or its affiliates. All rights reserved
Product Model:
iPAK2v2
Firmware Version:
V2.10
May 22 | Doc No 700253-2
When the
WAVx
checkbox is unchecked, the
AVx
outputs for each event must be individually set by checking the box.
Figure 58: NetFlash Valve Selection with Extended Features Configuration
9.7.3.2
Mutli-Electrode in Standard Mode
Standard
configuration always outputs the WAV signal on AV1 which limits the flexibility in programming a Multi-
Electrode weld program. In
NetFlash™,
check the
AVx
box corresponding to the desired valve and timing parameter to
execute during the weld sequence.
In the
Standard
mode, only a
WAV
output can be used. Auxiliary outputs can be used as Event-Outputs, such as turning
ON a Dump-Valve during post heat for a forge operation.
shows how to enable Auxiliary Output 2 [
AV2
] during
the Post-Heat and Hold interval of a weld program. The
WAV
signal is automatically assigned and stays ON throughout
the entire weld sequence.