47
IP2185EN - 2015-09-21
13. Commands
13.1 Testable safety devices
Command
Function
Description
1
2
NO
CLOSURE
The closure of the contact activates the closing operation.
CLOSURE
CLOSURE
The permanent closure of the contact enables automatic clo-
sure.
1
3
NO
OPENING
The closure of the contact activates the opening operation.
G1
8
NC
CLOSING
SAFETY
With DIP6=OFF, the opening of the contact reverses the
movement (re-opening) during the closing operation.
1
9
NC
STOP
The opening of the contact causes any movement to stop, and
all normal or emergency functions are excluded.
OPEN
NO
OPENING
Press quickly to activate the opening operation.
Command
Function
Description
1
8
NC
CLOSING
SAFETY
The opening of the contact reverses the movement (re-open-
ing) during the closing operation.
G1
SAFETY TEST
With DIP6=OFF, connect terminal G1 of the control panel to the
corresponding test terminal on the safety device. Terminal G1
activates a safety device test on each cycle. If the test fails, the
SA LED comes on and the test is repeated.
WARNING: jumper all NC contacts that are not used. Terminals with the same num-
ber are equal.
Before connecting the power supply, make sure the plate data correspond to those of
the mains power supply.
An omnipolar disconnection switch with a contact opening distance of at least 3mm must be
fitted on the mains supply.
Check there is an adequate residual current circuit breaker and overcurrent cut-out upstream
of the electrical system.
Use a H05RN-F 2G1.5 or H05RR-F 2G1.5 type electric cable, and connect it to terminals L
(brown) and N (blue) inside the automation. Secure the cable using a special cable clamp, then
remove the sheath only where the clamp is.
Connection to the mains power supply (in the section outside the automation) is made on an
independent channel, separated from the connections to the control and safety devices.
Make sure there are no sharp edges that may damage the power supply cable.
Make sure the mains power conductors (230V) and accessory power conductors (24V) are
separated.
12. Connecting the power supply
i
For other configurations, use the SPRINT SET card.
Summary of Contents for SPRINT L