Entre Matic PASS24 Installation Manual Download Page 3

3

DECLARATION OF CONFORMITY

Manufacturer: 

DITEC S.p.A. 

   

via Mons. Banfi, 3 

   

21042 Caronno Pertusella (VA) - ITALY.

Herewith declares that the microwave sensor PASS24 is in conformity with 

the provisions of the following EC directives: 

-  R&TTE Directive 1999/5/EC

-  EMC Directive 2004/108/EC 

-  Low Voltage Directive 2006/95/EC.

Caronno Pertusella, 15-03-2010       

Silvano Angaroni         

   

 

                                 (Managing Director)

GENERAL SAFETY PRECAUTIONS

This installation manual is intended for professionally competent personnel 

only.

Read the instructions carefully before beginning to install the product. Incor-

rect installation may be a source of danger.

Packaging materials (plastic, polystyrene, etc.) must not be allowed to litter 

the environment and must be kept out of the reach of children for whom they 

may be a source of danger.

Before beginning the installation check that the product is in perfect condi-

tion.

For  repairs  or  replacements  of  product  only  original  spare  parts  must  be 

used. These instruction must be kept and forwarded to all possible future 

user of the system.

To handle electronic parts, wear earthed antistatic conductive brace-

lets.

1.  TECHNICAL DATA

Power supply 

24 V=

Absorption at rest   

50 mA

Absorption when detecting

 

80 mA 

Frequency 

24,125 GHz

Output contact

 

 30 V / 1 A max (resistive load)

Protection degree 

IP54

Temperature 

from

 

-20° C to +55°C

Max installation height

 

3 m

2.  REFERENCE

[1]  Cover

[2]  Sensitivity adjustment trimmer

[3]  Command terminal board

[4]  Led / Operation indicator

[5]  Sensor module 

[6]  Adjustment bracket

3.  INSTALLATION AND FUNCTIONING

(Fig. 3) Remove the cover [1] by inserting a screwdriver in the hole on the 

upper part of the sensor. 

Securely fix the sensor to a flat surface using screws and plugs (not supplied) 

and position it so that it can monitor the entire area opposite the passage 

opening. 

NOTE: avoid putting any swaying objects - such as curtains, signs or plants 

- in the detection area. Ensure that rain and snow cannot fall directly onto 

the sensor or it doesn’t detect them, and also that it is not directed towards 

fluorescent lamps.

Output

relay

N.O.

Outside the 

detection area

Inside the 

detection area

Outside the 

detection area

Stand-by

Stand-by

Motion 

detection

 Led

OFF

OFF

ON

4

4.  ELECTRICAL CONNECTIONS

Make the connections indicated in fig. 5. 

WARNING: The product must be connected to an extra-low voltage power 

source (SELV) which is protected from overcurrent and shortcircuiting.

5.   ADJUSTING THE DETECTION AREAS

Selecting the type of detection area.

Choose the required form of the detection area, pointing the sensor module 

[5] as indicated in figures 7 and 8. 

(Fig.6) To select a restricted area, remove the sensor module cover, then 

remove the sensor module [5] and rotate it by 90° anticlockwise before insert-

ing it in the special connection.

Selecting the depth of the detection area.

The depth can be altered by changing the vertical positioning of the adjust-

ment bracket [6]. In the examples of figures 7 and 8, the vertical angle is 30°. 

NOTE: check the sensor does not detect the moving door wing.
Selecting the detection area

The position (towards the right or left) of the detection area is obtained by 

rotating the adjustment bracket [6] clockwise or anticlockwise.

Adjusting the sensitivity

Adjust the sensitivity of the detection area by means of the sensitivity adjust-

ment trimmer [2], as indicated in figures 7 and 8.

6.   TROUBLESHOOTING

Problem

Cause

Solution

It does not work Power supply voltage

Check the power supply

Faulty connection

Check the wiring and the 

connector

It does not 

always work

Sudden change in the de-

tection area conditions

Check the installation con-

ditions
Check the direction of the 

sensor and/or its sensitivity

It works by itself There is a moving object in 

the detection area

Remove the object

Presence  of  water  drops 

on the cover.

Clean the cover and check the 

sensor installation

The sensor detects 

rainfalls or snowfalls

Check the installation con-

ditions 

The  sensor  is  subject  to 

vibrations

Install the sensor firmly

The  sensor  detects  the 

moving door wing

Correctly adjust the detection 

area and sensitivity with TR1.

All right reserved

All data and specifications have been drawn up and checked with the gre-

atest  care.  The  manufacturer  cannot  however  take  any  responsibility  for 

eventual errors, ommisions or incomplete data due to technical or illustrative 

purposes.

IP2064EN - 2011-06-01

Reviews: