background image

61

Horizontal section

Vertical section

25

40

31

41

40

25

12

8

16

15

19

20

25

16

15

12

8

39

31

32

33

33

32

LS1

12

LS1

35

21

45

70

P

H

 (m

in

. 1

9

0

0

, m

a

x.

 3

0

0

0

) = H

1

 = H - 1

3

0 - H

2

12

0

H

2

 (m

in

. 3

2

0 , m

a

x.

 21

7

0

)

10

H (m

in

. 2

3

5

0

, m

a

x.

 4

2

0

0

)

175

30

22.5

HF

45

30

HM

10

60

45

14

5

L (min. 1715, max. 6000)

LF

10

PL = (L - 68 - 2X) / 2

LF

10

45

40

45

40

LTmax = L - 20

X (min. 30)

X (min. 30)

30

30

12

LM

LM

3.5

3.5

T49

IP2275 - 2017-04-30

44.  Vertical and horizontal section of 2 moving door wings and 2 fixed door wings  

with overlight (standard version)

Summary of Contents for Ditec PAM30STD

Page 1: ...i originali Montageanleitung für Standardprofilsysteme Originalsprachlichen Anweisungen Manuel d assemblage pour système d huisserie standard Instructions originales Manual de montaje para sistema de cierre estándar Instrucciones originales Manual de montagem para sistema de ferragem padrão Instruções originais EN IT DE FR ES PT IP2275 2017 04 30 www entrematic com ...

Page 2: ...orizzontale 1 anta mobile con apertura a destra versione francese Vertikal und Horizontalschnitt für 1 Fahrflügel mit Rechtsöffnung französische Version Section verticale et horizontale 1 vantail mobile avec ouverture à droite version française Sección vertical y horizontal de 1 hoja móvil con apertura a la derecha versión francés Secção vertical e horizontal de 1 folha móvel com abertura à direit...

Page 3: ...on Sezione verticale e orizzontale una anta mobile con apertura a destra e una anta fissa versione francese Vertikal und Horizontalschnitt für 1 Fahrflügel mit Rechtsöffnung und einem Stehflügel französische Version Section verticale et horizontale un vantail mobile avec ouverture à droite et un vantail fixe version française Sección vertical y horizontal de una hoja móvil con apertura a la derech...

Page 4: ... and horizontal section of 1 moving door wing and 1 fixed door wing with left hand opening and overlight french version Sezione verticale e orizzontale 1 anta mobile con apertura a sinistra 1 anta fissa e sopraluce installata in luce versione francese Vertikal und Horizontalschnitt für 1 Fahrflügel mit Linksöffnung 1 Stehflügel und Oberlicht Installation in der Lichte französische Version Section ...

Page 5: ...Vertikal und Horizontalschnitt für 2 Fahrflügel 2 Stehflügel und Oberlicht französische Version Section verticale et horizontale 2 vantaux mobiles 2 vantaux fixes et imposte version française Sección vertical y horizontal de 2 hojas móviles 2 hojas fijas y acristalado versión francés Secção vertical e horizontal de 2 folhas móveis 2 folhas fixas e bandeira versão francesa 46 Technical sections Sez...

Page 6: ...oor the reference dimension of the automation is indicated LT 3 Entrance exit door frame Ditec PAM30 Series Sliding door made with EN AW 6060 T5 UNI 9006 1 aluminium alloy extruded profiles 30 mm size suitable for DITEC automated installations with special devices that guarantee accident prevention surface finish with powder coating polyester powder in RAL colours Qualicoat or anodising EURAS fini...

Page 7: ...guenti criteri standard il vano passaggio PLmax viene considerato tra i montanti verticali delle ante fisse e o della cornice Il vano passaggio utile ha una tolleranza di 20 mm per ogni tipologia di porta viene indicata la dimensione di riferimento dell automazione LT 3 Serramento di ingresso uscita Serie Ditec PAM30 Porta scorrevole realizzata con profilati estrusi in lega di alluminio EN AW 6060...

Page 8: ...Rahmens berücksichtigt Die nutzbare lichte Öffnung hat eine Toleranz von 20 mm für jeden Tortyp wird die Bezugsgröße des Antriebs LT angegeben 3 Eingangs Ausgangsprofil Baureihe Ditec PAM30 Schiebetor aus stranggepressten Profilen aus Aluminiumlegierung EN AW 6060 UNI 9006 1 T5 Querschnitt 30 mm geeignet für Antriebsanlagen der Firma DITEC mit spezifischen Vorkehrungen um jede Art von Sicherheit u...

Page 9: ...verticaux des vantaux fixes et ou du cadre La baie de passage utile a une tolérance de 20 mm la dimension de référence de l automatisme est indiquée LT pour chaque type de porte 3 Huisserie d entrée sortie Série Ditec PAM30 Porte coulissante réalisée avec des profilés extrudés en alliage d aluminium EN AW 6060 UNI 9006 1 T5 section de 30 mm indiquée pour installations automatisées DITEC avec des s...

Page 10: ...es verticales de las hojas fijas y o del marco El hueco de paso útil tiene una tolerancia de 20 mm para cada tipo de puerta se indica la dimensión de referencia del automatismo LT 3 Cierre de entrada salida Serie Ditec PAM30 Puerta corredera realizada con perfiles extruidos de aleación de aluminio EN AW 6060 UNI 9006 1 T5 sección de 30 mm adecuada para instalaciones automatizadas DITEC con solucio...

Page 11: ...Lmax deve ser considerado entre os montantes verticais das portinholas fixas e ou do caixilho O vão útil de passagem tem uma tolerância de 20 mm para cada tipo de porta é indicada a dimensão de referência do automatismo LT 3 Ferragem de entrada saída Série Ditec PAM30 Porta de correr realizada com perfis extrudados em liga de alumínio EN AW 6060 UNI 9006 1 T5 secção de 30 mm adequada para instalaç...

Page 12: ...Hauteur utile de la baie dans le mur Altura útil hueco pared Altura útil do vão da parede PH Passage opening height Altezza vano passaggio HöhedesPlatzbedarfsfürdieÖffnung Hauteur de la baie de passage Altura hueco de paso Altura do vão de passagem H1 Effective height under beam Altezza utile sotto trave Nutzbare Höhe unter dem Kämpferprofil Hauteur utile sous montant Altura útil bajo la viga Altur...

Page 13: ...13 Visible surface 2085 2086 2088 2090 2087 2089 45 60 30 30 30 30 30 21 35 30 49 40 27 30 T01 IP2275 2017 04 30 Scale 1 1 5 Profiles shape ...

Page 14: ...14 Visible surface 2093 2458 4073 2092 2091 2226 35 25 50 27 40 5 15 6 35 36 24 14 36 22 5 51 30 2 49 30 40 T02 IP2275 2017 04 30 5 Profiles shape Scale 1 1 ...

Page 15: ...15 Visible surface 3127 3128 4480 3131 3130 17 16 5 67 5 38 39 70 30 53 30 23 39 5 18 16 36 120 30 T03 IP2275 2017 04 30 Scale 1 1 5 Profiles shape ...

Page 16: ...16 Visible surface 4085 4063 2096 2095 2094 180 167 5 151 41 23 6 5 T04 IP2275 2017 04 30 Scale 1 1 5 Profiles shape ...

Page 17: ...17 Visible surface 4671 2098 2139 SP14 PB5 2469 2141 2140 165 113 5 5 51 5 35 50 5 5 10 14 7 27 17 8 10 22 T05 IP2275 2017 04 30 Scale 1 1 5 Profiles shape Gaskets shape ...

Page 18: ...0 KAF30 T06 IP2275 2017 04 30 6 Accessories n 4 Clips n 8 TPS 4 8 x 32 n 1 Fixing Bracket n 1 Floor Guide n 2 Fixing Brackets n 8 TPS 4 8 x 32 Couple of Beam Endcups n 3 TC 4 8 x 13 n 2 TC 4 8 x 9 5 n 4 TC 3 9 x 13 ...

Page 19: ...19 KT4063 T07 IP2275 2017 04 30 6 Accessories n 12 TC 3 5 x 9 5 n 4 TE M6 x 20 n 2 Beam Older n 2 Nut n 2 Washer n 2 TE M8 x 25 ...

Page 20: ...20 48 97 30 100 30 20 5 30 K2097L 2097 K2097L ø 15 L L 15 7 5 7 5 L 15 80 18 3131 3130 T08 IP2275 2017 04 30 6 Accessories K2097L KGI ...

Page 21: ...21 2469 2141 2140 8 9 22 23 10 11 T09 IP2275 2017 04 30 Scale 1 1 7 Glass thickness ...

Page 22: ...ni verticali e orizzontali che seguiranno rappresentano a titolo puramente indicativo le automazioni VALOR Die nachfolgenden Beispiele der Vertikal und Horizontalschnitte stellen rein informativ die VALOR Antriebe dar Les exemples suivants de sections verticales et horizontales représentent à titre purement indicatif les automatismes VALOR Los ejemplos de secciones verticales y horizontales siguie...

Page 23: ...23 40 179 145 45 116 VAL30A3 V4671 VALOR V4671 T11 IP2275 2017 04 30 Scale 1 2 8 Applications ...

Page 24: ...24 45 158 5 22 5 181 175 145 23 22 5 6 VAL30A3 V4063 VALOR V4063 T12 IP2275 2017 04 30 Scale 1 2 8 Applications ...

Page 25: ...25 75 45 65 100 190 REXA30 REX S T13 IP2275 2017 04 30 Scale 1 2 8 Applications ...

Page 26: ... 2 27 HM 10 30 PH H H min 1900 max 3000 3 5 110 40 5 175 145 60 45 LT min 2L 88 40 40 25 10 L min 800 max 1500 PL L min 10 30 12 LM 3 5 T14 IP2275 2017 04 30 9 Vertical and horizontal section of 1 moving door wing with right hand opening standard version ...

Page 27: ... PH H H min 1900 max 3000 3 5 110 40 5 175 145 60 45 LT min 2L 2 40 40 25 L min 800 max 2000 PL L 40 min 10 30 12 LM 3 5 40 T15N IP2275 2017 04 30 10 Vertical and horizontal section of 1 moving door wing with right hand opening installed within doorway standard version ...

Page 28: ...27 26 LT min 2L 88 40 40 25 10 L min 800 max 1500 PL L min 10 30 12 LM 3 5 HM 10 30 PH H H min 1900 max 3000 3 5 110 40 5 175 145 60 45 T16 IP2275 2017 04 30 11 Vertical and horizontal section of 1 moving door wing with left hand opening standard version ...

Page 29: ...on 6 3 HM 10 30 PH H H min 1900 max 3000 3 5 110 40 5 175 145 60 45 LT min 2L 2 40 40 25 L min 800 max 2000 PL L 40 min 10 30 12 LM 40 T17N IP2275 2017 04 30 12 Vertical and horizontal section of 1 moving door wing with left hand opening standard version ...

Page 30: ...0 PH H H min 1900 max 3000 3 5 165 40 5 145 60 45 LT min 2L 88 40 40 25 10 L min 800 max 2000 PL L min 10 30 12 LM 3 5 179 V4671 T18 Valor only not Rex S IP2275 2017 04 30 13 Vertical and horizontal section of 1 moving door wing with right hand opening french version ...

Page 31: ... L min 800 max 2000 PL L 40 min 10 30 12 LM 3 5 40 HM 10 30 PH H H min 1900 max 3000 3 5 165 40 5 179 145 60 45 V4671 T19 Valor only not Rex S IP2275 2017 04 30 14 Vertical and horizontal section of 1 moving door wing with right hand opening installed within doorway french version ...

Page 32: ...min 2L 88 40 40 25 10 L min 800 max 1500 PL L min 10 30 12 LM 3 5 HM 10 30 PH H H min 1900 max 3000 3 5 165 40 5 145 60 45 179 T20 Valor only not Rex S IP2275 2017 04 30 15 Vertical and horizontal section of 1 moving door wing with left hand opening french version ...

Page 33: ... min 1900 max 3000 3 5 165 40 5 145 60 45 LT min 2L 2 40 40 25 L min 800 max 2000 PL L 40 min 10 30 12 LM 40 179 T21 Valor only not Rex S IP2275 2017 04 30 16 Vertical and horizontal section of 1 moving door wing with left hand opening installed within doorway french version ...

Page 34: ...900 max 3000 H1 H 175 H min 2075 max 3175 165 175 3 5 40 5 HM 10 30 60 45 145 LT min 2L 88 40 40 25 10 L min 800 max 1500 PL L min 10 30 12 LM 3 5 T22 IP2275 2017 04 30 17 Vertical and horizontal section of 1 moving door wing with beam with right hand opening standard version ...

Page 35: ...1 H 175 H min 2075 max 3175 165 175 3 5 40 5 HM 10 30 60 45 145 LT min 2L 2 40 40 25 L min 800 max 2000 PL L 40 min 10 30 12 LM 3 5 40 T23N IP2275 2017 04 30 18 Vertical and horizontal section of 1 moving door wing with beam with right hand opening installed within doorway standard version ...

Page 36: ... 40 25 10 L min 800 max 1500 PL L min 10 30 12 LM 3 5 10 175 PH min 1900 max 3000 H1 H 175 H min 2075 max 3175 165 175 3 5 40 5 HM 10 30 60 45 145 T24 IP2275 2017 04 30 19 Vertical and horizontal section of 1 moving door wing with beam with left hand opening standard version ...

Page 37: ... H1 H 175 H min 2075 max 3175 165 175 3 5 40 5 HM 10 30 60 45 145 LT min 2L 2 40 40 25 L min 800 max 2000 PL L 40 min 10 30 12 LM 40 T25N IP2275 2017 04 30 20 Vertical and horizontal section of 1 moving door wing with beam with left hand opening installed within doorway standard version ...

Page 38: ...00 max 3000 H1 H 130 H2 120 H2 min 320 max 2170 10 175 40 5 3 5 45 HM 10 30 60 45 145 LT min 2L 88 40 40 25 10 L min 800 max 1500 PL L min 10 30 12 LM 3 5 T26 IP2275 2017 04 30 21 Vertical and horizontal section of 1 moving door wing with right hand opening and overlight standard version ...

Page 39: ... H 130 H2 120 H2 min 320 max 2170 10 175 40 5 3 5 45 HM 10 30 60 45 145 LT min 2L 2 40 40 25 L min 800 max 2000 PL L 40 min 10 30 12 LM 3 5 40 T27N IP2275 2017 04 30 22 Vertical and horizontal section of 1 moving door wing with right hand opening installed within doorway and overlight standard version ...

Page 40: ...in 800 max 1500 PL L min 10 30 12 LM 3 5 45 PH min 1900 max 3000 H1 H 130 H2 120 H2 min 320 max 2170 10 H min 2350 max 4200 175 40 5 3 5 45 HM 10 30 60 45 145 T28 IP2275 2017 04 30 23 Vertical and horizontal section of 1 moving door wing with left hand opening and overlight standard version ...

Page 41: ...2 120 H2 min 320 max 2170 10 H min 2350 max 4200 175 40 5 3 5 45 HM 10 30 60 45 145 LT min 2L 2 40 40 25 L min 800 max 2000 PL L 40 min 10 30 12 LM 40 T29N IP2275 2017 04 30 24 Vertical and horizontal section of 1 moving door wing with left hand opening installed within doorway and overlight standard version ...

Page 42: ... 5 PH H H min 1900 max 3000 HF 181 HM 10 60 45 145 175 23 L min 1600 max 4000 PL L 43 2 LF 15 30 12 LM LT min L 85 40 3 5 40 25 10 30 T30 Valor only not Rex S IP2275 2017 04 30 25 Vertical and horizontal section of 1 moving door wing and 1 fixed door wing with right hand opening french version ...

Page 43: ... 40 30 12 LM LT min L 35 40 3 5 LF 15 25 10 30 35 13 70 30 30 22 5 PH H H min 1900 max 3000 HF 181 HM 10 60 45 145 175 23 T31 Valor only not Rex S IP2275 2017 04 30 26 Vertical and horizontal section of 1 moving door wing and 1 fixed door wing with right hand opening installed within doorway french version ...

Page 44: ... 4000 PL L 43 2 LF 15 30 12 LM LT min L 85 40 40 30 10 25 3 5 35 13 70 30 30 22 5 PH H H min 1900 max 3000 HF 181 HM 10 60 45 145 175 23 T32 Valor only not Rex S IP2275 2017 04 30 27 Vertical and horizontal section of 1 moving door wing and 1 fixed door wing with left hand opening french version ...

Page 45: ...3 2 40 30 12 LM LT min L 35 40 LF 15 30 10 25 3 5 35 13 70 30 30 22 5 PH H H min 1900 max 3000 HF 181 HM 10 60 45 145 175 23 T33 Valor only not Rex S IP2275 2017 04 30 28 Vertical and horizontal section of 1 moving door wing and 1 fixed door wing with left hand opening installed within doorway french version ...

Page 46: ...H min 1900 max 3000 H1 H 175 H min 2075 max 3175 HF 165 175 HM 10 60 45 145 L min 1650 max 3000 PL L 68 X 2 LF 45 X min 30 10 40 30 12 LM LT min L 20 40 3 5 T34 IP2275 2017 04 30 29 Vertical and horizontal section of 1 moving door wing and 1 fixed door wing with beam with right hand opening standard version ...

Page 47: ... PH min 1900 max 3000 H1 H 175 H min 2075 max 3175 HF 165 175 HM 10 60 45 145 L min 1650 max 3000 PL L 68 X 2 LF 45 X min 30 10 40 30 12 LM LT min L 20 40 3 5 T35 IP2275 2017 04 30 30 Vertical and horizontal section of 1 moving door wing and 1 fixed door wing with beam with left hand opening standard version ...

Page 48: ...X 2 LF X min 30 10 40 30 12 LM LT min L 20 40 3 5 70 175 30 30 22 5 PH H1 H 185 H min 1900 max 3000 HF 185 HM 10 60 45 145 4 181 35 13 30 T36 Valor only not Rex S IP2275 2017 04 30 31 Vertical and horizontal section of 1 moving door wing and 1 fixed door wing with beam with right hand opening french version ...

Page 49: ...8 X 2 LF X min 30 10 40 30 12 LM LT min L 20 40 30 3 5 70 175 30 30 22 5 PH H1 H 185 H min 1900 max 3000 HF 185 HM 10 60 45 145 4 181 35 13 T37 Valor only not Rex S IP2275 2017 04 30 32 Vertical and horizontal section of 1 moving door wing and 1 fixed door wing with beam with left hand opening french version ...

Page 50: ... H 130 H2 120 H2 min 320 max 2170 10 H min 2350 max 4200 175 30 22 5 HF 45 30 HM 10 60 45 145 L min 1650 max 3000 PL L 68 X 2 LF 45 X min 30 10 40 30 12 LM LT min L 20 40 3 5 T38 IP2275 2017 04 30 33 Vertical and horizontal section of 1 moving door wing and 1 fixed door wing with right hand opening and overlight standard version ...

Page 51: ...F 45 X min 30 10 40 30 12 LM LT min L 20 40 3 5 35 21 45 45 70 PH min 1900 max 3000 H1 H 130 H2 120 145 H2 min 320 max 2170 10 H min 2350 max 4200 175 30 22 5 HF 30 HM 10 60 45 T39 IP2275 2017 04 30 34 Vertical and horizontal section of 1 moving door wing and 1 fixed door wing with left hand opening and overlight standard version ...

Page 52: ...n 30 10 40 30 12 LM LT min L 20 40 3 5 70 175 30 30 22 5 HF HM 10 60 45 145 35 13 PH H1 H 181 H2 181 H2 min 240 max 2109 10 H min 2331 max 4200 45 45 3 LS 30 T40 Valor only not Rex S IP2275 2017 04 30 35 Vertical and horizontal section of 1 moving door wing and 1 fixed door wing with right hand opening and overlight french version ...

Page 53: ...X min 30 10 40 30 12 LM LT min L 20 40 30 3 5 70 175 30 30 22 5 HF HM 10 60 45 145 35 13 PH H1 H 181 H2 181 H2 min 240 max 2109 10 H min 2331 max 4200 45 45 3 T41 Valor only not Rex S IP2275 2017 04 30 36 Vertical and horizontal section of 1 moving door wing and 1 fixed door wing with left hand opening and overlight french version ...

Page 54: ... 23 26 27 27 26 L min 800 max 3000 PL L LT min 2L 88 30 30 12 LM LM 3 5 3 5 min 10 min 10 25 HM 10 30 PH H H min 1900 max 3000 3 5 110 40 5 175 145 60 45 T42 IP2275 2017 04 30 37 Vertical and horizontal section of 2 moving door wings standard version ...

Page 55: ... 26 28 L min 800 max 3000 PL L LT min 2L 88 30 30 12 LM LM 3 5 3 5 min 10 min 10 25 HM 10 30 PH H H min 1900 max 3000 3 5 165 40 5 145 60 45 179 T43 Valor only not Rex S IP2275 2017 04 30 38 Vertical and horizontal section of 2 moving door wings french version ...

Page 56: ... 800 max 3000 PL L LT min 2L 88 30 30 12 LM LM 3 5 3 5 min 10 min 10 25 10 175 PH min 1900 max 3000 H1 H 175 H min 2075 max 3175 165 175 3 5 40 5 HM 10 30 60 45 145 T44 IP2275 2017 04 30 39 Vertical and horizontal section of 2 moving door wings with beam standard version ...

Page 57: ...00 max 3000 H1 H 130 H2 120 H2 min 320 max 2170 10 H min 2350 max 4200 175 40 5 3 5 45 HM 10 30 145 60 45 L min 800 max 3000 PL L LT min 2L 88 30 30 12 LM LM 3 5 3 5 min 10 min 10 25 T45 IP2275 2017 04 30 40 Vertical and horizontal section of 2 moving door wings with overlight standard version ...

Page 58: ...5 PH min 1900 max 3000 H1 H 175 H min 2075 max 3175 HF 165 175 HM 10 60 45 145 L min 1715 max 6000 LF 10 PL L 68 2X 2 LF 10 45 40 45 40 LTmax L 20 X min 30 X min 30 30 30 12 LM LM 3 5 3 5 T46 IP2275 2017 04 30 41 Vertical and horizontal section of 2 moving door wings and 2 fixed door wings with beam standard version ...

Page 59: ...0 max 6600 40 40 LT min L 70 30 30 12 LM LM 3 5 3 5 LF 25 10 15 LF 15 PL L 98 2 30 30 35 13 70 30 30 22 5 PH H H min 1900 max 3000 HF 181 HM 10 60 45 145 175 23 T47 Valor only not Rex S IP2275 2017 04 30 42 Vertical and horizontal section of 2 moving door wings and 2 fixed door wings french version ...

Page 60: ... PL L 68 2X 2 LF 10 40 40 LTmax L 20 X min 30 X min 30 30 30 12 LM LM 3 5 3 5 70 175 30 30 22 5 PH H1 H 185 H min 1900 max 3000 HF 185 HM 10 60 45 145 4 181 35 13 30 30 T48 Valor only not Rex S IP2275 2017 04 30 43 Vertical and horizontal section of 2 moving door wings and 2 fixed door wings with beam french version ...

Page 61: ... 3000 H1 H 130 H2 120 H2 min 320 max 2170 10 H min 2350 max 4200 175 30 22 5 HF 45 30 HM 10 60 45 145 L min 1715 max 6000 LF 10 PL L 68 2X 2 LF 10 45 40 45 40 LTmax L 20 X min 30 X min 30 30 30 12 LM LM 3 5 3 5 T49 IP2275 2017 04 30 44 Vertical and horizontal section of 2 moving door wings and 2 fixed door wings with overlight standard version ...

Page 62: ...68 2X 2 LF 10 40 40 LTmax L 20 X min 30 X min 30 30 30 12 LM LM 3 5 3 5 30 30 70 175 30 30 22 5 HF HM 10 60 45 145 35 13 PH H1 H 181 H2 181 H2 min 240 max 2109 10 H min 2331 max 4200 45 45 3 T50 Valor only not Rex S IP2275 2017 04 30 45 Vertical and horizontal section of 2 moving door wings and 2 fixed door wings with overlight french version ...

Page 63: ...63 1 40 12 30 74 T51 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 64: ...64 2 40 25 40 5 3 5 T52 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 65: ...65 3 40 25 40 5 3 5 T53 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 66: ...66 4 12 40 30 74 T54 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 67: ...67 5 40 12 30 T55 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 68: ...68 6 40 12 30 T56 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 69: ...69 7 40 12 30 82 5 T57 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 70: ...70 8 40 3 5 49 49 3 5 T58 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 71: ...71 9 25 30 10 35 T59 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 72: ...72 10 40 12 30 T60 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 73: ...73 11 25 30 10 35 T61 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 74: ...74 12 40 3 5 49 49 3 5 T62 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 75: ...75 13 40 12 30 82 5 T63 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 76: ...76 14 40 12 30 T64 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 77: ...77 15 25 45 10 T65 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 78: ...78 16 25 45 10 T66 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 79: ...79 17 25 30 10 T67 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 80: ...80 18 25 30 10 T68 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 81: ...81 19 25 45 10 T69 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 82: ...82 20 25 45 10 T70 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 83: ...83 21 25 45 10 T71 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 84: ...84 22 25 45 10 T72 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 85: ...85 23 40 2 T73 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 86: ...86 24 40 2 T74 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 87: ...87 25 12 30 30 T75 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 88: ...88 26 40 5 3 5 30 60 10 T76 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 89: ...89 26A 26A 26A 26A 60 10 30 40 5 3 5 28 5 30 53 T77 IP2275 2017 04 30 46 Technical sections Out of scale ...

Page 90: ...90 27 31 45 30 3 5 40 5 14 PH H T78 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 91: ...91 28 45 30 3 5 40 5 PH H 28 17 T79 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 92: ...92 29 45 30 3 5 40 5 10 45 120 175 PH H1 175 145 31 14 T80 IP2275 2017 04 30 46 Technical sections Scale 1 2 ...

Page 93: ...93 30 175 145 45 30 3 5 40 5 31 14 120 PH H1 45 T81 IP2275 2017 04 30 46 Technical sections Scale 1 2 ...

Page 94: ...94 31 45 10 25 T82 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 95: ...95 32 33 60 10 70 22 5 30 30 T83 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 96: ...96 32A 33A 32A 33A 32A 33A 32A 33A 60 10 30 53 30 30 22 5 70 37 T84 IP2275 2017 04 30 46 Technical sections Out of scale ...

Page 97: ...97 35 34 45 PH H 158 5 22 5 181 175 145 23 30 30 22 5 22 5 6 T85 IP2275 2017 04 30 46 Technical sections Scale 1 2 ...

Page 98: ...98 36 37 45 10 45 175 PH H1 175 145 30 30 22 5 120 14 T86 IP2275 2017 04 30 46 Technical sections Scale 1 2 ...

Page 99: ...99 38 39 45 145 30 30 22 5 175 4 181 PH H1 22 5 6 T87 IP2275 2017 04 30 46 Technical sections Scale 1 2 ...

Page 100: ...100 40 41 175 145 120 PH H1 45 14 30 30 22 5 45 T88 IP2275 2017 04 30 46 Technical sections Scale 1 2 ...

Page 101: ...101 42 43 45 145 30 30 22 5 175 181 PH H1 22 5 6 45 3 T89 IP2275 2017 04 30 46 Technical sections Scale 1 2 ...

Page 102: ...102 44 45 10 25 T90 IP2275 2017 04 30 46 Technical sections Scale 1 1 ...

Page 103: ...1 2 15 1 2 29 1 0 2 x Ø 4 s v 2 x 4 5 2xØ4 sv 2x45 1 5 20 1 9 15 1 2 9 1 2 9 1 0 20 29 20 5 2xØ4 sv 2x45 20 10 1 3 M T91 IP2275 2017 04 30 47 Processes Moving door wing Anta mobile Fahrflügel Vantail mobile Hoja móvil Portinhola móvel ...

Page 104: ... 3 9 s v 2 x 4 5 2xØ4 sv 2x45 29 5 Ø4 sv 2x45 5 5 5 12 17 Ø2 5 2xØ4 sv 2x45 9 39 2xØ4 sv 2x45 25 12 9 17 1 2 1 2 F T92 IP2275 2017 04 30 47 Processes Fixed door wing Anta fissa Seitenteil Vantail fixe Hoja fija Portinhola fixa ...

Page 105: ...105 A C A C B B A A B B IP2275 2017 04 30 T93 48 Details of additional dimensions HM HF HVO HVM HVF VALOR LVM LF LVF LM LVM LF LVF LM LVO LVO C C ...

Page 106: ...106 B1 A1 left A1 right B2 A2 left A2 right B3 A3 left A3 right T95 IP2275 2017 04 30 49 Instructions for assembling and installing list of types ...

Page 107: ...ing V2094 V2085 V2090 KAF30 V2094 V2089 V2087 RGR2469 RGR2140 RGR2141 KAM30 V2095 V2086 RGR2469 RGR2140 RGR2141 V2091 V2087 V2096 VSP14 VGR2098 V2089 T96 IP2275 2017 04 30 49 Instructions for door assembling and installing ...

Page 108: ...3 4 Frame post fixing Floor guide fixing Post closing fixing Simplified beam fixing Automation climbing Operator fixing Wing positioning T97 IP2275 2017 04 30 49 Instructions for assembling and installing doors type A1 B1 ...

Page 109: ... 12 9 8 Fixing frame installation Fix wing positioning Post closing fixing Section Support beam fixing End cap Automation climbing T98 IP2275 2017 04 30 49 Instructions for assembling and installing doors type A2 B2 ...

Page 110: ...Fixing frame installation Fix wing positioning Post closing fixing Section Floor guide fixing Beam holder positioning Wing lateral side fixing T99 IP2275 2017 04 30 49 Instructions for assembling and installing doors type A3 B3 ...

Page 111: ...111 19 21 22 20 Automation climbing Operator fixing Beam cover Beam cover fixing T100 IP2275 2017 04 30 49 Instructions for assembling and installing doors type A3 B3 ...

Page 112: ...112 23 25 26 24 Mobile wing bracket fixing Carrier adjustment Belt adjustment Electrolock adjustment 1 2 T101 IP2275 2017 04 30 49 Instructions for assembling and installing ...

Page 113: ...oder Änderungen sind ohne vorherige schriftliche Zustimmung von Entrematic Group AB nicht erlaubt Tous les droits relatifs à ce matériel sont la propriété exclusive d Entrematic Group AB Bien que les contenus de cette publication aient été rédigés avec le plus grand soin Entrematic Group AB ne saurait être tenue responsable en cas de dommages dérivant d erreurs ou d omissions éventuelles Nous nous...

Page 114: ...IP2275 2017 04 30 Entrematic Group AB Lodjursgatan 10 SE 261 44 Landskrona Sweden www entrematic com ...