EDSL450 User manual 

 

 

1.5

 

Program selector switch 

The Program switch is used to select the required program. The program switch can be installed close 
to the door or at another location in the building. 

 

1.6

 

Program selection and interaction 

The program switch is used to select the program that will be used for the sliding door. 

1.7

 

Program selection 

Selection is done with a key switch. The switch can be positioned in six different positions, five of 
which are programs and one is used for error reporting and reset (position F). 

See the table below for the list of programs that can be selected. To prevent multiple changes to the 
selected program while switching from one to another, the switch has to remain stationary for more 
than two seconds before the new program is activated. 

Position 

Function 

A  

Program close

. Door is closed and locked. Sensors will not open the door. Only 

porter input can be used to open the door. 

Program exit-only + full open

. Door opens on activation of inside motion sensor. 

An open door will remain open if either inside or outside presence sensor is 
active. Door is opened to the full open position. 

Program aut full open.

 The door will open on activation of all sensors, 

inside or outside. Door is opened to full open position. 

Program aut reduced open

. The door will open on activation of all 

sensors, inside or outside. Open position will be to the reduced open position or 
full open position depending on the activator. This program cannot be used in 
escape routes. 

Program open + full open.

 Door opens and remains open during this program 

regardless of sensors active. 

Error reporting and reset. 

When the controller has a warning or is in error, placing 

the switch in this position will cause program switch to display the warning or 
error code. 

A

B

C

D

E

F

Summary of Contents for EDSL450

Page 1: ... Dynamics BV Copying scanning alterations or modifications are expressly forbidden without the prior written consent of Entrance Dynamics BV Rights reserved for changes without prior notice Entrance Dynamics sliding door operator EDSL450 User manual Original instructions ...

Page 2: ... Program selection and interaction 8 1 7 Program selection 8 1 7 1 Program indication 9 1 7 2 Status indication 9 1 7 3 Override program 9 1 7 4 Show error and warning code 9 1 7 5 Reset error 10 1 7 6 Initialise door 10 1 7 7 Warning and error codes 10 2 Safety 12 2 1 Safety symbols used in this manual 12 3 Operating instructions 13 3 1 Daily Procedures 13 3 1 1 Daily start procedure 13 3 1 2 Dai...

Page 3: ...EDSL450 User manual 3 4 3 1 Clean the door 15 5 Troubleshooting 16 5 1 Checklist before you contact your local service provider 16 6 Declaration of incorporation 17 ...

Page 4: ...EDSL450 User manual 4 Revision information Date Revision Description 21 08 2014 1 00 Initial publication 01 12 2014 1 10 Changed declaration ...

Page 5: ...nance as specified in this user manual and in the logbook supplied with your sliding door This maintenance must be done by qualified service engineers trained to recognise possible problems and to replace parts that have a defined life expectancy Dismantling and disposal of the door operator Dismantling of the door or parts thereof may only be carried out by qualified personnel These tasks are com...

Page 6: ...lled on the door leaves to reduce draft The door leaves are suspended from the carriage wheels The door adapter profile connects to the carriage wheels and the door leaves The bottom of the door leaves are kept in position by the floor guides 1 2 Drive unit The drive unit opens and closes the sliding door The door leaves are connected to the drive unit via the carriage wheel brackets The drive uni...

Page 7: ...ectrical lock optional External activation device optional Push buttons intercom installation optional 1 3 Safety System The safety system opens or closes the door in case of emergency The safety system consists of Panic button Safety sensors Emergency battery back up Fire alarm optional 1 4 Activation The different types of optional activators are Radar motion detection Active infrared motion and...

Page 8: ...on A Program close Door is closed and locked Sensors will not open the door Only porter input can be used to open the door B Program exit only full open Door opens on activation of inside motion sensor An open door will remain open if either inside or outside presence sensor is active Door is opened to the full open position C Program automatic full open The door will open on activation of all sen...

Page 9: ...e program switch retry Orange pulsing Door controller is in service mode Service mode cannot be altered with the program switch 1 7 3 Override program The program used by the door controller can override the selection made with the program switch The indicator will always show the program selected if possible If the active program is different then the program selected with the switch the indicato...

Page 10: ... position for more than 3 seconds but less than 8 seconds If the reset is selected more than 8 seconds no actions are performed but the warning or error code is shown instead of the active program 1 7 7 Warning and error codes 1 7 7 1 Table Warning codes A B C D E F Warning description Service required Battery missing Battery low voltage Battery operation Battery hardware of controller Radar insid...

Page 11: ...erature error Motor drive fault Motor inverted while operational Connect motor Motor shorted Motor and or encoder Encoder error Low home current Escape motor movement direction Memory error Overvoltage error Door controller error Door mechanical connection No close position No open position Software error Untested unit ...

Page 12: ...perate or do maintenance on the door Make sure there are no persons or equipment in the working area of the door before you operate the door Do not remove or immobilize safety equipment installed on or near the door Do not operate the door if it has any defects Report defects to the supervisor immediately Do not operate the door after the date of the next scheduled maintenance The date of the next...

Page 13: ...op procedure Examine the door for damage If damage is found o Apply suitable warning signs around the door and on the door leaves o Contact your local service provider If no damage is found o If the door is in an escape route and or the only entrance make sure that no person is in the building o Set the program selector to the required position 3 1 3 Daily function check after start procedure Appr...

Page 14: ...Floor guides Make sure the leaves are guided properly and remove any debris from floor track follow the local regulations but not less as every 12 months Door complete Annual inspection made by authorised Service Partner 4 2 Replacement schedule Apart from regulatory maintenance we at Entrance Dynamics think it is important for our doors to be treated the same way as a vehicle change the oil and t...

Page 15: ...ollowing items have to be considered for replacement Hook lock Combined Radars Sensors Safety devices Other activators Control unit Program switch Emergency button 4 3 Preventive maintenance procedures 4 3 1 Clean the door Do not use the door leaf or Drive unit to support a ladder when you do maintenance on a door Always use ladders as specified in local health and safety instructions Do not use a...

Page 16: ...in switch and fuse are serviceable Switch the power supply on Program Selector in open position Change the position on the program selector If it is necessary to adjust the opening or closing speed or the sensitivity or detection field of sensors please contact your local service provider 5 1 Checklist before you contact your local service provider Make sure the main electrical power supply is on ...

Page 17: ...es RoHS Technical documentation for safe integration is provided Harmonized European standards which have been applied EN 60335 1 EN 61000 6 2 EN 61000 6 3 EN ISO 13849 1 EN 16005 Other standards or technical specifications which have been applied DIN 18650 1 2 EN 60335 2 103 EC type examination or certificate issued by notified body IFT 0757 No 14 000152 PB01 SP 0402 No SC0707 14 for full address...

Reviews: