Entes GEMO Quick Start Manual Download Page 5

Digital Input LED

ON: 

Digital input ON

OFF

: Digital input OFF

Digital Output LED

ON

: Digital output ON

OFF

: Digital output OFF

Setting Interface

In order to configure the device settings from the web interface, it must be connected to the 

computer with a micro USB cable. Then you could access the interface via http://usb.entes or 

192.168.7.1. The device’s password is the last 4 digits of the MAC ID. You could check the device’s 

connection status to GSM on this interface.

Attention

•  Make sure your SIM Card’s PIN Code is deactivated.

•  Assemble the antenna in the device’s box to antenna port on front side.

•  Modbus adresses of all devices connected to the modem must be different from each other and  

  the serial port settings must be same. (Baudrate, parity, data bit, stop bit)

•  Make sure that the terminals of the serial communication line (A-B-GND) between the devices to  

  be read and your device are correct.

•  Energized GEMO-02 models do not allow to read any address other than the first two different  

 addresses.

•  Make sure the IP settings of the device are suitable for your network structure (subnet mask,  

  gateway address, DNS, IP address).

• 

If there is any firewall at your network, make sure the communication port (502 or 700) is available.

IT Instruction:

Share this information with your IT authorized or technical personnel responsible for internet 

access. 

If you wish to access any ENTES service via static IP address by your internet provider (TCP server, 

static IP communication);

Give access authorization over default port 502 or the relevant port you configured.

Interface

Operating Voltage Range

Supply Voltage

85-265 VAC/DC

Digital Input

5-30 VDC

Digital Output

5-30 VDC

Device Connection

Make the MODBUS connection of the device and make the Ethernet connection. Insert the SIM 

card into the slot on the device. The device’s supply voltage range is 85-265 VAC/DC. Supply the 

device with a suitable voltage within the supply range.

PC

Micro USB

SIM Card

Antenna

Ethernet

(Models with an 

Ethernet port)

85-265 VAC / DC

Digital I/O

RS-232

RX TX

RS-485

A(+)B(-)

GND

LED Indicators
Status LED 

Red - ON: 

The device is energized but IP has not been received yet, so you will not be able to access 

the WEB interface.

Green - ON: 

The device is energized and IP has been received. You could connect to the WEB interface.

White Flasher: 

Reset factory settings (In progress)

Yellow - ON:

 USB connected.

Red and Blue Sequential Flasher:

 Device has malfunction. Please contact ENTES Customer Service.

Ethernet LED

ON: 

Connection is ON

Flasher: 

Connection is ON, communication is available.

OFF: 

Connection is OFF

GSM LED

ON: 

Connection is ON

Signal Strength Flasher: 

The number of green LED lights indicates the signal strength. There are 5 

levels in total.

Slow Flasher: 

SIM card is not inserted.

OFF: 

Connection is OFF

Summary of Contents for GEMO

Page 1: ...GEMO Modem H zl KurulumTalimat Quick Start Manual Schnellinstallationsanleitung A8792 Rev 2...

Page 2: ...aray z ne eri im sa layamazs n z Ye il S rekli Cihazda enerji var IP al nm WEB aray z ne ba lanabilirsiniz Beyaz Fla r Fabrika ayarlar na d n l yor Sar S rekli USB ba land K rm z ve Mavi Ard k Fla r...

Page 3: ...ayarlar n n ise birbiri ile ayn olmas gerekmektedir Baudrate parite data bit stop bit Okunacak cihazlar ile cihaz n z aras ndaki seri haberle me hatt n n u lar n n A B GND do rulu undan emin olunuz GE...

Page 4: ...485 A B GND LED Indicators Status LED Red ON The device is energized but IP has not been received yet so you will not be able to access the WEB interface Green ON The device is energized and IP has be...

Page 5: ...from each other and the serial port settings must be same Baudrate parity data bit stop bit Make sure that the terminals of the serial communication line A B GND between the devices to be read and you...

Page 6: ...ingeschaltet IP wurde empfangen Sie k nnen sich mit der WEB Schnittstelle verbinden Wei er Blinker Zur cksetzen auf die Werkseinstellungen Gelb Leuchtet st ndig USB angeschlossen Rotes und blaues Blin...

Page 7: ...inander unterscheiden und die Einstellungen der seriellen Schnittstelle m ssen bereinstimmen Baudrate parite data bit stop bit Vergewissern Sie sich dass die Anschl sse A B GND der seriellen Kommunika...

Page 8: ...icaret A S Adr Dudullu OSB 1 Cadde No 23 34776 mraniye STANBUL T RK YE Tel 90 216 313 01 10 Fax 90 216 314 16 15 E mail iletisim entes com tr contact entes eu Web www entes com tr www entes eu Call Ce...

Reviews: