Entes DTR-10 Manual Download Page 4

ASTRONOMIC RELAY 

(DTR-10)

ASTRONOMIC PHOTOCELL RELAY 

(DTR-14)

A2407 / Rev.5

Wrong application :

 This relay will switch

on at sunset timeand will switch off at

sunrise time.

Example 2:

 This relay will switch on at

sunrise time and will switch off at sunset

time.

Example 1:

 This relay will switch on via

photocell sensor and will switch off on

02:00 AM.

SU

C2:

C1:

00
02
04
06
08
10
12
14
16

22

20

18

24

ESC

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

ESC

In this application, there is a mistake at P06

program when, switch off time settings are

done for weekdays. Relays will switch off

according  to  the  sunrise  time  and  so

program settings are wrong for Tuesday,

Thursday and Saturday.

ESC

SU

C2:

C1:

00
02
04
06
08
10
12
14
16

22

20

18

24

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

ESC

SU

C2:

C1:

00
02
04
06
08
10
12
14
16

22

20

18

24

ESC

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

SET

ESC

4

This illustration is available for DTR-14.

Summary of Contents for DTR-10

Page 1: ...above example if photocell sensor perceives the darkness after 10 seconds photocell symbol does not light on the main menu and the relay switches on within 1 minute As above example if photocell sensor detects the daylight after 10 seconds photocell detected symbol lights on the main menu and the relay switches off within 1 minute NOTE Device can only switch on between 12 00 AM and 24 00 PM Device...

Page 2: ...me time Date information will be displayed instead of Lock sign will be removed In case of escaping the service mode the last program continues its execution For user safety it is not possible to enter to lock and factory settings modes when service mode is activated 5 GEOGRAPHICAL LOCATION SETTING Values which are mentioned in Table 1 are calculated before Therefore there is no need to calculate ...

Page 3: ... 10 2009 03 00 No known DST 15 03 2009 00 00 11 10 2009 00 00 No known DST No known DST 29 03 2009 03 00 25 10 2009 04 00 No known DST 29 03 2009 02 00 25 10 2009 03 00 05 04 2009 03 00 04 10 2009 02 00 No known DST 22 03 2009 00 00 22 10 2009 00 00 No known DST No known DST 29 03 2009 02 00 25 10 2009 03 00 Tablo 1 Geographical locations in the world No known DST No known DST No known DST No know...

Page 4: ...SET SET SET SET SET SET SET SET SET SET SET SET SET ESC In this application there is a mistake at P06 program when switch off time settings are done for weekdays Relays will switch off according to the sunrise time and so program settings are wrong for Tuesday Thursday and Saturday ESC SU C2 C1 00 02 04 06 08 10 12 14 16 22 20 18 24 SET SET SET SET SET SET SET SET SET SET SET SET SET SET SET SET S...