show lldp port local-info
SecureStack C2 Configuration Guide
4-19
Example
This
example
shows
how
to
display
the
local
system
information
stored
for
port
ge.4.1.
describes
the
output
fields
of
this
command.
C2(rw)->show lldp port local-info ge.4.1
Local Port : ge.4.1 Local Port Id: ge.4.1
--------------------
Port Desc : ... 1000BASE-TX RJ45 Gigabit Ethernet Frontpanel Port
Mgmt Addr : 10.21.64.100
Chassis ID : 00-E0-63-93-74-A5
Sys Name : LLDP PoE test Chassis
Sys Desc : Enterasys Networks, Inc.
Sys Cap Supported/Enabled : bridge,router/bridge
Auto-Neg Supported/Enabled : yes/yes
Auto-Neg Advertised : 10BASE-T, 10BASE-TFD,
100BASE-TX, 100BASE-TXFD,
1000BASE-TFD,
Bpause
Operational Speed/Duplex/Type : 100 full tx
Max Frame Size (bytes) : 1522
Vlan Id : 1
LAG Supported/Enabled/Id : no/no/0
Protocol Id : Spanning Tree v-3 (IEEE802.1s)
LACP v-1
GVRP
PoE Device : PSE device
PoE Power Source : primary
PoE MDI Supported/Enabled : yes/yes
PoE Pair Controllable/Used : false/spare
PoE Power Class : 2
PoE Power Limit (mW) : 15400
PoE Power Priority : high
describes
the
information
displayed
by
the
show
lldp
port
local
‐
info
command.
Table 4-4
show lldp port local-info Output Details
Output Field
What it Displays...
Local Port
Identifies the port for which local system information is displayed.
Local Port Id
Mandatory basic LLDP TLV that identifies the port transmitting the
LLDPDU. Value is ifName object defined in RFC 2863.
Port Desc
Optional basic LLDP TLV. Value is ifDescr object defined in RFC 2863.
Mgmt Addr
Optional basic LLDP TLV. IPv4 address of host interface.
Chassis ID
Mandatory basic LLDP TLV that identifies the chassis transmitting the
LLDPDU. Value is MAC address of chassis.
Sys Name
Optional basic LLDP TLV. Value is the administratively assigned name for
the system.
Sys Desc
Optional basic LLDP TLV. Value is sysDescr object defined in RFC 3418.
Sys Cap Supported/Enabled
Optional basic LLDP TLV. System capabilities, value can be bridge and/or
router.
Summary of Contents for SecureStack C2
Page 1: ...SecureStack C2 Stackable Switches Configuration Guide Firmware Version 5 1 xx P N 9033991 16 ...
Page 2: ......
Page 28: ...xxvi ...
Page 106: ...set ssl 3 52 Basic Configuration ...
Page 226: ...Creating a Basic SNMP Trap Configuration 6 38 SNMP Configuration ...
Page 278: ...show spantree nonforwardingreason 7 52 Spanning Tree Configuration ...
Page 302: ...set garp timer 8 24 802 1Q VLAN Configuration ...
Page 448: ...show dhcp pool configuration 14 30 DHCP Server Configuration ...
Page 454: ...no license advanced 15 6 Preparing for Router Mode ...