C2RPS-CHAS2 Power Shelf
Power Supply Slots
2
Dimensions (H x W x D)*
48.2 cm (19.0”) x 5.5 cm (2.2”) x 18.0 cm (7.0”)
Weight
0.95 kg (2.09 lbs)
Note: dimensions include integrated rack mount ears
C2RPS-CHAS8 Power Shelf
Power Supply Slots
8
Dimensions (H x W x D)*
44.0 cm (117.3”) x 22.26 cm (8.77”) x 26.4 cm (10.4”)
Weight
5.27 kg (11.6 lbs)
C2RPS-PSM Power Supply
Dimensions (H x W x D)
19.6 cm (7.7”) x 5.2 cm (2.04”) x 25.7 cm (10.1”)
Net Weight (Unit Only)
1.75 kg (3.85 lbs)
Gross Weight (Packaged Unit)
3.20 kg (7.04 lbs)
MTBF
300,000 hours
Operating Temperature
5° C to 40° C (41° F to 104° F)
Storage Temperature
-30° C to 73° C (-22° F to 164° F)
Operating Relative Humidity
10% to 90%
AC Input Frequency Range
50-60 Hz
AC Input Voltage Range
100 - 240 VAC
Maximum Output Power
156 W continuous
C2RPS-POE Power Supply
Dimensions (H x W x D)*
4.45 cm (1.75”) x 44.5 cm (17.5”) x 16.5 cm (6.5”)
Net Weight (Unit Only)
3.47 kg (7.63 lbs)
Gross Weight (Packaged Unit)
4.95 kg (10.89 lbs)
MTBF
589,644 hours at 25° C (77° F)
Operating Temperature
5° C to 40° C (41° F to 104° F)
Storage Temperature
-30° C to 73° C (-22° F to 164° F)
Operating Relative Humidity
10% to 90%
AC Input Frequency Range
50-60 Hz
AC Input Voltage Range
100 - 240 VAC
Maximum Output Power
500 W continuous
Switch Model Specifications (cont.)
Redundant Power Supply Equipment Specifications
A2H124-24
A2H124-24P
A2H124-48
A2H124-48P
Agency and Regulatory
Standard Specifications
Safety
UL 60950-1, CSA 22.1
60950, EN 60950-1, and
IEC 60950-1
UL 60950-1, CSA 22.1
60950, EN 60950-1, and IEC
60950-1
UL 60950-1, CSA 22.1
60950, EN 60950-1, and IEC
60950-1
UL 60950-1, CSA 22.1
60950, EN 60950-1, and IEC
60950-1
EMC
FCC Part 15 (Class A),
ICES-003 (Class A), BSMI,
VCCI V-3, AS/NZS CISPR 22
(Class A), EN 55022 (Class
A), EN 55024, EN 61000-
3-2, and EN 61000-3-3
FCC Part 15 (Class A), ICES-
003 (Class A), BSMI, VCCI
V-3, AS/NZS CISPR 22 (Class
A), EN 55022 (Class A), EN
55024, EN 61000-3-2, and EN
61000-3-3
FCC Part 15 (Class A), ICES-003
(Class A), BSMI, VCCI V-3, AS/
NZS CISPR 22 (Class A), EN
55022 (Class A), EN 55024, EN
61000-3-2, and EN 61000-3-3
FCC Part 15 (Class A), ICES-
003 (Class A), BSMI, VCCI V-3,
AS/NZS CISPR 22 (Class A), EN
55022 (Class A), EN 55024, EN
61000-3-2, and EN 61000-3-3