background image

iii

Electromagnetic Compatibility (EMC)

This

 

product

 

complies

 

with

 

the

 

following:

 

47

 

CFR

 

Parts

 

2

 

and

 

15,

 

ICES

003,

 

89/336/EEC,

 

EN

 

60825,

 

EN

 

55022,

 

EN

 

61000

3

2,

 

EN 61000

3

3,

 

EN

 

55024,

 

AS/NZS

 

CISPR

 

22,

 

VCCI

 

V

3.

 

Compatibilidad Electromágnetica (EMC)

Este

 

producto

 

de

 

Enterasys

 

cumple

 

con

 

lo

 

siguiente:

 

47

 

CFR

 

Partes

 

2

 

y

 

15,

 

ICES

003,

 

89/336/EEC,

 

EN

 

60825,

 

EN

 

55022,

 

EN 55024,

 

EN 61000

3

2,

 

EN

 

61000

3

3,

 

AS/NZS

 

CISPR

 

22,

 

VCCI

 

V

3.

Elektro-magnetische Kompatibilität (EMC)

Dieses

 

Produkt

 

entspricht

 

den

 

folgenden

 

Richtlinien:

 

47

 

CFR

 

Parts

 

2

 

and

 

15,

 

ICES

003,

 

89/336/EEC,

 

EN

 

60825,

 

EN

 

55022,

 

EN 61000

3

2,

 

EN

 

61000

3

3,

 

EN

 

55024,

 

AS/NZS

 

CISPR

 

22,

 

VCCI

 

V

3.

 

Hazardous Substances

This

 

product

 

complies

 

with

 

the

 

requirements

 

of

 

European

 

Directive,

 

2002/95/EC,

 

Restriction

 

of

 

Hazardous

 

Substances

 

(RoHS)

 

in

 

Electrical

 

and

 

Electronic

 

Equipment.

European Waste Electrical and Electronic Equipment (WEEE) Notice

In

 

accordance

 

with

 

Directive

 

2002/96/EC

 

of

 

the

 

European

 

Parliament

 

on

 

waste

 

electrical

 

and

 

electronic

 

equipment

 

(WEEE):

1.

The

 

symbol

 

above

 

indicates

 

that

 

separate

 

collection

 

of

 

electrical

 

and

 

electronic

 

equipment

 

is

 

required

 

and

 

that

 

this

 

product

 

was

 

placed

 

on

 

the

 

European

 

market

 

after

 

August

 

13,

 

2005,

 

the

 

date

 

of

 

enforcement

 

for

 

Directive

 

2002/96/EC.

2.

When

 

this

 

product

 

has

 

reached

 

the

 

end

 

of

 

its

 

serviceable

 

life,

 

it

 

cannot

 

be

 

disposed

 

of

 

as

 

unsorted

 

municipal

 

waste.

  

It

 

must

 

be

 

collected

 

and

 

treated

 

separately.

3.

It

 

has

 

been

 

determined

 

by

 

the

 

European

 

Parliament

 

that

 

there

 

are

 

potential

 

negative

 

effects

 

on

 

the

 

environment

 

and

 

human

 

health

 

as

 

a

 

result

 

of

 

the

 

presence

 

of

 

hazardous

 

substances

 

in

 

electrical

 

and

 

electronic

 

equipment.

4.

It

 

is

 

the

 

users’

 

responsibility

 

to

 

utilize

 

the

 

available

 

collection

 

system

 

to

 

ensure

 

WEEE

 

is

 

properly

 

treated.

For

 

information

 

about

 

the

 

available

 

collection

 

system,

 

please

 

go

 

to

 

http://www.enterasys.com/services/support/

 

or

 

contact

 

Enterasys

 

Customer

 

Support

 

at

 

353

 

61

 

705586

 

(Ireland).

Summary of Contents for RoamAbout RBT-8110

Page 1: ...RoamAbout Wireless Networking RBT 8110 Wireless Switch Installation Guide P N 9034285 01...

Page 2: ......

Page 3: ...nuteman Road Andover MA 01810 2006 Enterasys Networks Inc All rights reserved Part Number 9034285 01 November 2006 ENTERASYS ENTERASYS NETWORKS ENTERASYS ROAMABOUT ROAMABOUT ENTERASYS MATRIX LANVIEW M...

Page 4: ...s for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio le...

Page 5: ...Equipment WEEE Notice In accordance with Directive 2002 96 EC of the European Parliament on waste electrical and electronic equipment WEEE 1 The symbol above indicates that separate collection of ele...

Page 6: ...asures Declaration of Conformity Application of Council Directive s 89 336 EEC 73 23 EEC Manufacturer s Name Enterasys Networks Inc Manufacturer s Address 50 Minuteman Road Andover MA USA 01810 Europe...

Page 7: ...ENTERASYS OR YOUR DEALER IF ANY WITHIN TEN 10 DAYS FOLLOWING THE DATE OF RECEIPT FOR A FULL REFUND IF YOU HAVE ANY QUESTIONS ABOUT THIS AGREEMENT CONTACT ENTERASYS NETWORKS LEGAL DEPARTMENT AT 978 68...

Page 8: ...LAIMS ALL WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY SATISFACTORY QUALITY FITNESS FOR A PARTICULAR PURPOSE TITLE AND NON INFRINGEMENT WITH...

Page 9: ...breach of this Agreement 12 WAIVER A waiver by Enterasys of a breach of any of the terms and conditions of this Agreement must be in writing and will not be construed as a waiver of any subsequent bre...

Page 10: ...viii...

Page 11: ...n Pre Configuration Tasks 3 1 Wireless Switch Configuration Tasks 3 1 Using the CLI quickstart Command 3 1 quickstart Command Procedure 3 3 Configuring RoamAbout Wireless Switches Using RASM 3 5 Preco...

Page 12: ...x...

Page 13: ...I commands that you enter on a RoamAbout Switch RAS to configure and manage the Mobility System wireless LAN WLAN RoamAbout Switch Manager Users Guide Explains how to plan configure deploy and manage...

Page 14: ...jury or death due to an electrical hazard Riesgo de electrocuci n Advierte contra una acci n que pudiera resultar en lesi n corporal o la muerte debido a un riesgo el ctrico Elektrische Spannung Warnu...

Page 15: ...ttached front rack mount brackets One non redundant power supply One power cord U S version One null modem cable Mid mount rack mounting accessory kit Front Panel Controls and Indicators Figure 1 1 sh...

Page 16: ...A continuous amber light indicates a link between the system and the network to which it is connected A blinking amber light indicates network activity Status Power A continuous blue light indicates...

Page 17: ...le 1 4 A Keyboard mouse connectors C Power supply B Video connector D Power connector Table 1 3 Power Supply Specifications Parameter Description Input voltage 100 to 125 Vac 6 A 50 60 Hz 200 to 240 V...

Page 18: ...perature 40 C to 70 C 104 F to 158 F Altitude 60 meters 197 feet below sea level to 4000 meters 13 123 feet above sea level Non Operating humidity 5 to 95 non condensing Acoustic noise Sound Pressure...

Page 19: ...la del ambiente a nivel de habitaci n Por lo tanto debe considerar la posibilidad de instalar el equipo en un entorno compatible con la temperatura ambiente m xima Tma de 40 C 104 F Reduced Air Flow...

Page 20: ...este problema Reliable Earthing Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch...

Page 21: ...r as usadas de acuerdo con las instrucciones Enterasys le recomienda que se ponga en contacto con el departamento de Asistencia t cnica en www enterasys com services support contact si requiere servic...

Page 22: ...is section describes how to install the RBT 8110 into a rack Rack mount options include Front mounting Front mount and mid mount Front Mount Figure 2 1 shows the RBT 8110 front panel being attached to...

Page 23: ...ched and a mid mount placement example To attach the chassis to the rack perform the following steps 1 Use the two mounting holes closest to the center of the chassis for more balanced mounting positi...

Page 24: ...Rack Mounting 2 6 Installation...

Page 25: ...sks Wireless Switch Configuration Tasks Once the wireless switch is physically installed and powered on you can set up its configuration This section describes two ways to configure a newly installed...

Page 26: ...te generated if you type usernames and passwords for users of unencrypted SSIDs One of the questions the script asks is the country code For a list of valid country codes refer to either the RoamAbout...

Page 27: ...SSIDs user information or distributed access points RBT 8110 aabbcc quickstart This will erase any existing config Continue n y Answer the following questions Enter for help C to break out System Name...

Page 28: ...o exit Do you wish to configure access points y y Enter a port number 1 2 on which an AP resides cr to exit 2 Enter AP model on port 2 RBT 1602 Enter a port number 1 2 on which an AP resides cr to exi...

Page 29: ...ertificates in the Connection Security area 6 Click Save 7 Open the network plan for the site or create a new one 8 Access the Create Mobility Exchange wizard a Select the Configuration toolbar option...

Page 30: ...the switch to use the MSS DHCP client to obtain this information from a DHCP server in the local network where the switch will be deployed Alternatively you can statically configure the information Th...

Page 31: ...nown name wlan config srv RBT 8110 set ip alias wlan config srv 172 16 22 84 6 Enable the auto config option RBT 8110 set auto config enable 7 Save the configuration changes RBT 8110 save config 8 Res...

Page 32: ...lso has a local DNS server However the local DNS domain name is different from the corporate DNS domain name where the RASM server is located The static DNS configuration on the switch overrides the D...

Page 33: ...dant PoE DHCP A Distributed AP uses IP for communication and relies on DHCP to obtain IP parameters Therefore DHCP services must be available on the subnet that the AP is connected to DHCP must provid...

Page 34: ...Preparing the Network for Distributed Access Points 3 10 Configuration...

Page 35: ...Input voltage 1 3 Install rack 2 1 Intended audience xi K Kit contents 1 1 N Notices BSMI EMC iv Class A ITE ii EMC iii FCC ii General ii Industry Canada ii Product Safety ii VCCI iv O Output voltage...

Page 36: ......