Module Placement in a Matrix E7 Chassis
2-2 Network Requirements
no
aggregations
will
be
formed
and
the
DFE
‐
Platinum
modules
will
function
normally
(that
is,
Spanning
Tree
will
block
redundant
paths).
For
details
about
the
commands
involved
with
configuring
the
Link
Aggregation
function,
refer
to
the
Enterasys
Matrix
DFE
‐
Platinum
Series
Configuration
Guide
.
Module Placement in a Matrix E7 Chassis
If
you
want
to
mix
6x1xxx,
6x2xxx,
6x3xxx,
and
7x4xxx
series
modules
in
the
same
Matrix E7
chassis,
it
is
necessary
to
have
a
DFE
‐
Platinum
module
FTM1
‐
to
‐
FTM2
bridging
module
installed
in
the
chassis
and
also
follow
the
module
placement
rules
described
in
the
section,
“Backplane
Connections
and
Installation
Rules,”
on
page 3
‐
3
to
successfully
bridge
data
traffic
to
some
or
all
modules
in
the
chassis.
FTM Bridge Function and Network Expansion Module
Unlike
the
7H4203
‐
72,
7H4382
‐
49,
7H4383
‐
49,
and
7H4385
‐
49
DFE
‐
Platinum
bridge
modules
(not
described
in
this
guide)
,
the
7H4382
‐
25
can
support
both
the
FTM
bridging
function
and
an
optional
network
expansion
module
at
the
same
time
without
restrictions.
10BASE-T Network
When
connecting
a
10BASE
‐
T
segment
to
any
of
the
module
fixed
front
panel
ports
of
the
7H4382
‐
25,
ensure
that
the
network
meets
the
Ethernet
network
requirements
of
the
IEEE 802.3
‐
2002
standard
for
10BASE
‐
T.
Refer
to
the
Cabling
Guide
for
details.
100BASE-TX Network
Fixed
front
panel
ports
of
the
7H4382
‐
25
provide
a
connection
that
supports
Category
5
UTP
cabling.
The
device
at
the
other
end
of
the
twisted
pair
segment
must
meet
IEEE
802.3
‐
2002
100BASE
‐
TX
Fast
Ethernet
network
requirements
for
the
devices
to
operate
at
100 Mbps.
Refer
to
the
Cabling
Guide
for
details.
Note:
If a port is to operate at 100 Mbps, Category 5 cabling must be used. Category 3
cabling does not meet 100 Mbps specifications. For 10 Mbps operation only, Category 3 or
Category 5 cabling can be used. Refer to
“100BASE-TX Network”
on page 2-2 for
information about 100BASE-TX networks and cabling.
Note:
The fixed ports of the module support Category 5 UTP cabling with an impedance
between 85 and 111 ohms for 100 Mbps operation.
The module is capable of operating at either 10 or 100 Mbps. The module automatically
senses the speed of the other device and adjusts its speed accordingly.
Summary of Contents for Matrix 7H4382-25
Page 2: ......
Page 12: ...x...
Page 16: ...xiv...
Page 26: ...LANVIEW Diagnostic LEDs 1 6 Introduction...
Page 54: ...Completing the Installation 3 26 Installation...