Enterasys Matrix 6H352-25 Installation Manual Download Page 5

ENTERASYS NETWORKS, INC.

PROGRAM LICENSE AGREEMENT

BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT,

CAREFULLY READ THIS LICENSE AGREEMENT.

This document is an agreement (“Agreement”) between You, the end user, and Enterasys Networks, Inc. (“Enterasys”) 
that sets forth your rights and obligations with respect to the Enterasys software program (“Program”) in the package. 
The Program may be contained in firmware, chips or other media. UTILIZING THE ENCLOSED PRODUCT, YOU 
ARE AGREEING TO BECOME BOUND BY THE TERMS OF THIS AGREEMENT, WHICH INCLUDES THE 
LICENSE AND THE LIMITATION OF WARRANTY AND DISCLAIMER OF LIABILITY. IF YOU DO NOT 
AGREE TO THE TERMS OF THIS AGREEMENT, RETURN THE UNOPENED PRODUCT TO ENTERASYS OR 
YOUR DEALER, IF ANY, WITHIN TEN (10) DAYS FOLLOWING THE DATE OF RECEIPT FOR A FULL 
REFUND.

IF YOU HAVE ANY QUESTIONS ABOUT THIS AGREEMENT, CONTACT ENTERASYS NETWORKS 
(603) 332-9400. Attn:  Legal Department.

1.

LICENSE. You have the right to use only the one (1) copy of the Program provided in this package subject to the 

terms and conditions of this License Agreement.

You may not copy, reproduce or transmit any part of the Program except as permitted by the Copyright Act of the 

United States or as authorized in writing by Enterasys.

2.

OTHER RESTRICTIONS. You may not reverse engineer, decompile, or disassemble the Program.

3.

APPLICABLE LAW. This License Agreement shall be interpreted and governed under the laws and in the state 

and federal courts of New Hampshire. You accept the personal jurisdiction and venue of the New Hampshire courts.

4.

EXPORT REQUIREMENTS. You understand that Enterasys and its Affiliates are subject to regulation by 

agencies of the U.S. Government, including the U.S. Department of Commerce, which prohibit export or diversion of 
certain technical products to certain countries, unless a license to export the product is obtained from the U.S. Government 
or an exception from obtaining such license may be relied upon by the exporting party.

If the Program is exported from the United States pursuant to the License Exception CIV under the U.S. Export 

Administration Regulations, You agree that You are a civil end user of the Program and agree that You will use the 
Program for civil end uses only and not for military purposes.

If the Program is exported from the United States pursuant to the License Exception TSR under the U.S. Export 

Administration Regulations, in addition to the restriction on transfer set forth in Sections 1 or 2 of this Agreement, You 
agree not to (i) reexport or release the Program, the source code for the Program or technology to a national of a country 
in Country Groups D:1 or E:2 (Albania, Armenia, Azerbaijan, Belarus, Bulgaria, Cambodia, Cuba, Estonia, Georgia, 
Iraq, Kazakhstan, Kyrgyzstan, Laos, Latvia, Libya, Lithuania, Moldova, North Korea, the People’s Republic of China, 
Romania, Russia, Rwanda, Tajikistan, Turkmenistan, Ukraine, Uzbekistan, Vietnam, or such other countries as may be 
designated by the United States Government), (ii) export to Country Groups D:1 or E:2 (as defined herein) the direct 
product of the Program or the technology, if such foreign produced direct product is subject to national security controls 
as identified on the U.S. Commerce Control List, or (iii) if the direct product of the technology is a complete plant or any 
major component of a plant, export to Country Groups D:1 or E:2 the direct product of the plant or a major component 
thereof, if such foreign produced direct product is subject to national security controls as identified on the U.S. 
Commerce Control List or is subject to State Department controls under the U.S. Munitions List.

Summary of Contents for Matrix 6H352-25

Page 1: ...9033547 6H352 25 Fast Ethernet Installation Guide FAST ENET 6H352 25 GROUP GROUP SELECT RESET COM CPU 11X 1X G R O U P 1 23X 13X G R O U P 2 GROUP 3547_01...

Page 2: ......

Page 3: ...N IF ENTERASYS NETWORKS AND ITS LICENSORS HAVE BEEN ADVISED OF KNOWN OR SHOULD HAVE KNOWN THE POSSIBILITY OF SUCH DAMAGES Enterasys Networks Inc 35 Industrial Way Rochester NH 03866 5005 Enterasys Net...

Page 4: ...se the user will be required to correct the interference at his own expense WARNING Changes or modifications made to this device which are not expressly approved by the party responsible for complianc...

Page 5: ...erce which prohibit export or diversion of certain technical products to certain countries unless a license to export the product is obtained from the U S Government or an exception from obtaining suc...

Page 6: ...mentation and media ENTERASYS DISCLAIMS ALL WARRANTIES OTHER THAN THOSE SUPPLIED TO YOU BY ENTERASYS IN WRITING EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABI...

Page 7: ...0950 EN 60825 Equipment Type Environment Networking Equipment for use in a Commercial or Light Industrial Environment We the undersigned hereby declare under our sole responsibility that the equipment...

Page 8: ......

Page 9: ...P Address Discovery 1 3 1 4 Half Duplex Full Duplex Auto Negotiation 1 4 1 5 SmartTrunk 1 4 1 6 Remote Monitoring RMON 1 4 1 7 Broadcast Suppression 1 5 1 8 Port VLAN Redirect Functions 1 5 1 9 Traffi...

Page 10: ...sis 3 5 3 5 Connecting to the Network 3 7 3 6 Completing the Installation 3 10 4 TROUBLESHOOTING 4 1 Using LANVIEW 4 1 4 2 Troubleshooting Checklist 4 5 4 3 Using the RESET Button 4 7 A SPECIFICATIONS...

Page 11: ...the SmartSwitch 6000 Chassis 3 6 3 3 Connecting a Twisted Pair Segment to the 6H352 25 3 8 3 4 Crossover Cable RJ45 Pinouts 3 9 3 5 Straight Through Cable RJ45 Pinouts 3 9 4 1 LANVIEW LEDs 4 2 4 2 RES...

Page 12: ...x Tables Table Page 3 1 Contents of Module Carton 3 2 4 1 LANVIEW LEDs 4 3 4 2 Troubleshooting Checklist 4 5 1 1 Specifications for the 6H352 25 Module A 1 A 2 COM Port Pin Assignments A 2...

Page 13: ...this guide to completely understand the 6H352 25 capabilities and how to install the modules A general working knowledge of Ethernet and IEEE 802 3 type data communications networks and their physical...

Page 14: ...etwork operational problems Appendix A Specifications contains information on functionality and operating specifications connector pinouts environmental requirements and physical properties Appendix B...

Page 15: ...ion that may be of special importance TIP Conveys helpful hints concerning procedures or actions CAUTION Contains information essential to avoid damage to the equipment ELECTRICAL HAZARD Warns against...

Page 16: ...orks products in the network A description of your network environment layout cable type etc Network load and frame size at the time of trouble if known The device history i e have you returned the de...

Page 17: ...alled in the MATRIX E7 However DCM is supported when the 6H352 25 module is installed in the SmartSwitch 6000 chassis The 6H352 25 ports can be configured to control traffic in several ways including...

Page 18: ...1 2 Introduction Figure 1 1 The 6H352 25 Module FAST ENET 6H352 25 GROUP GROUP SELECT RESET COM CPU 11X 1X G R O U P 1 23X 13X G R O U P 2 GROUP 3547_01...

Page 19: ...col BootP server on the network without requiring a user to enter an IP address through Local Management When the 6H352 25 is connected to the network and powered up Runtime IP Address Discovery RAD c...

Page 20: ...l then the other interface automatically comes out of Blocking mode and forwards all of the traffic This is fine for redundancy purposes However it is not the most efficient use of resources SmartTrun...

Page 21: ...itch 1 9 TRAFFIC RATE LIMITING The Traffic Rate Limiting feature enables the SmartSwitch device to control traffic rates on a per port per priority basis The network administrator can configure a rate...

Page 22: ...r the Generic Attribute Registration Protocol GARP applications GARP VLAN Registration Protocol GVRP and or GARP Multicast Registration Protocol GMRP GARP is a protocol or set of rules that outlines a...

Page 23: ...module can be either in band or out of band In band remote management is possible through any SNMP compliant Network Management Software such as Enterasys Networks Webview and Aprisma s SPECTRUM for O...

Page 24: ...ariety of industry standard MIBs including RFC 1213 MIB II RFC 1757 RMON RFC 1493 Bridge MIB RFC 1354 FIB MIB and RFC 1190 Path MTU Discovery A full suite of Enterasys Networks Enterprise MIBs provide...

Page 25: ...for proper operation Refer to the SmartTrunk User s Guide for additional information 2 2 10BASE T NETWORK When connecting a 10BASE T segment to any of the 6H352 25 ports 1 through 24 ensure that the...

Page 26: ...02 3u 100BASE TX Fast Ethernet network requirements for the devices to operate at 100 Mbps Refer to the Enterasys Networks Cabling Guide for details NOTE The fixed ports of the 6H352 25 support Catego...

Page 27: ...stalling Optional HSIMs VHSIMs or Memory Upgrade Section 3 2 Installing the 6H352 25 into the MATRIX E7 Chassis Section 3 3 Installing the 6H352 25 into the SmartSwitch 6000 Chassis Section 3 4 Connec...

Page 28: ...ere are any signs of damage Refer to Getting Help for details 3 2 INSTALLING OPTIONAL HSIM VHSIM OR FLASH MEMORY UPGRADE If the 6H352 25 is to be installed with an optional HSIM or VHSIM refer to the...

Page 29: ...be reshipped Observe all precautions to prevent damage from Electrostatic Discharge ESD CAUTION Failure to observe static safety precautions could cause damage to the 6H352 25 Follow static safety ha...

Page 30: ...7 6C107 1 2 3 Backplane Connectors POWER OK REDUNDANCY FAN STATUS 6C207 1 ACON 1 0 AC ON POWER OK REDUNDANCY FAN STATUS 6C207 1 ACON 1 0 AC ON 6C407 Metal Back Panel Circuit Card Card Guides Slot Num...

Page 31: ...s for any updated information concerning installing the modules into the SmartSwitch 6000 chassis Otherwise the installation procedure from Section 3 4 can be followed with the exception that the 6C10...

Page 32: ...ng the 6H352 25 into the SmartSwitch 6000 Chassis 1 2 3 4 5 PS1 PS2 Slot Number 3547_03 Circuit Card Card Guides Metal Back Panel Plastic Locking Tab Backplane Connector FAST ENET 6H352 25 GROUP GROUP...

Page 33: ...a twisted pair segment to the 6H352 25 as follows 1 Ensure that the device connected to the other end of the segment is powered ON 2 Connect the twisted pair segment to the 6H352 25 by inserting the...

Page 34: ...e receive and transmit activity for that group of segments is then indicated by the RX and TX LEDs for each segment b Verify that the cabling being used is Category 5 UTP with an impedance between 85...

Page 35: ...his document If a link is not established contact Enterasys Networks Refer to Getting Help in About This Guide for details 4 Repeat steps 1 through 3 above until all connections have been made TO Othe...

Page 36: ...secure the cables by running the cables along the strain relief bracket and tying them to the bracket using cable ties 2 The 6H352 25 is now ready to be configured through Local Management Refer to t...

Page 37: ...quick observation of the network status to aid in diagnosing network problems Viewing Receive and Transmit Activity Only one group of segments may be viewed at a time To view the receive and transmit...

Page 38: ...ng blinking and solid used in Table 4 1 indicate the following Flashing indicates an LED is flashing randomly Blinking indicates an LED is flashing at a steady rate approximately 50 on 50 off Solid in...

Page 39: ...Amber Blinking Crippled Contact Enterasys Networks for technical support Solid Testing If the LED remains amber for more than several minutes contact Enterasys Networks for technical support Green Sol...

Page 40: ...g Indicates activity Rate indicates data rate None Amber Blinking Port in standby Port may be disabled due to Spanning Tree 1 Ensure that the port is not disabled 2 Contact Enterasys Networks for tech...

Page 41: ...TER RETURN may take up to four times Incorrect terminal setup Refer to the MATRIX E7 Series and SmartSwitch 6000 Series Modules Local Management User s Guide for proper setup procedures Improper conso...

Page 42: ...tSwitch 6000 Series Modules Local Management User s Guide for the instructions to set the type of STA 2 Review the network design and delete unnecessary loops 3 If the problem continues contact Entera...

Page 43: ...Figure 4 2 RESET Button CAUTION Pressing the RESET button resets the device and all current switching being performed by the module is halted A network downtime of up to two minutes will result from...

Page 44: ...ntime may result as the module reenters the network NOTE Pressing the RESET button while the 6H352 25 is already in reset mode is not recommended If the RESET button is pressed while the 6H352 25 is i...

Page 45: ...100 Mbps 10BASE T and 100BASE TX compliant with 24 RJ45 connectors Interface Slot Slot accepts optional High Speed Interface Module HSIM or Very High Speed Interface Module VHSIM to provide a variety...

Page 46: ...1 F to 104 F 30 C to 73 C 22 F to 164 F Storage Temperature Operating Relative Humidity 5 to 90 non condensing Table A 2 COM Port Pin Assignments Pin Signal Name Input Output 1 Transmit Data XMT Outpu...

Page 47: ...ets the following safety and electromagnetic compatibility EMC requirements Safety UL 1950 CSA C22 2 No 950 73 23 EEC EN 60950 and IEC 950 Electromagnetic Compatibility EMC FCC Part 15 CSA C108 8 89 3...

Page 48: ......

Page 49: ...grading FLASH memory Section B 3 B 1 REQUIRED TOOLS Use the following tools to perform the procedures provided in this appendix Antistatic wrist strap Phillips screwdriver CAUTION An antistatic wrist...

Page 50: ...For Enterasys Networks use only Switch 5 COM Port Autobaud The default OFF position enables Autobaud sensing on the COM port for Local Management sessions Changing the switch to the ON position disab...

Page 51: ...in FLASH memory Switch 7 Clear NVRAM Changing the position of this switch resets NVRAM on the next power up of the device All user entered parameters such as the IP address device names etc are reset...

Page 52: ...e SmartSwitch to expand from 8 to 16 MB This section explains how to locate and add replace the FLASH memory For details on getting help refer to Getting Help in About This Guide B 3 1 Locating the FL...

Page 53: ...shown in Figure B 3 insert the FLASH memory down between the connector 2 Pivot the FLASH memory downward so the connector clips align with the two side notches of the FLASH memory and the connector cl...

Page 54: ...connectors for an optional HSIM or VHSIM Depending on the HSIM or VHSIM installed one or both connectors are used Figure B 4 HSIM and VHSIM Connector Locations NOTE The installation instructions for...

Page 55: ...ssignments A 2 Connecting to the network 3 7 Connectivity introduction to 1 3 D Distributed Chassis Management 1 7 support 3 3 3 5 Document conventions xiii F FLASH installation B 5 Flow Control 1 6 F...

Page 56: ...xii Remote Monitoring RMON introduction to 1 4 RESET button 4 7 Runtime IP address discovery introduction to 1 3 S SecureFast Switching support 3 5 SmartTrunk introduction to 1 4 Specifications A 1 S...

Reviews: