393800
‐
2
Rev
1:
02.058.2017.
KJK
We
reserve
the
right
to
change
technical
data
without
notice.
http://www.ensy.no
Page 11
Supply
and
Extract
air
should
have
the
same
value
as
the
MAX
value
under
4.5.1.3
(Set
to
100%
from
factory.)
Even
if
it
is
installed
an
"active"
kitchen
ventilator
with
piping
not
connected
towards
the
unit,
the
KV
plug
must
get
the
signal
to
see
that
kitchen
ventilator
is
activated.
This
can
be
done
by
using
a
a
pressure
switch
in
the
exhaust
tube
from
the
ventilator.
Then
Extract
set
down
to
around
50%
or
less
to
compensate
for
the
extract
air
in
the
hood.
Note!
If
KV
signal
plug
is
not
in
use
for
cooker
hood
then
you
can
use
the
signal
to
get
more
supply
air
when
to
fire
up
a
fireplace.
Then
adjust
so
that
supply
air
delivers
more
air
than
extract
air
fan.
In
this
case
you
must
use
a
switch
and
not
impulse
switch.
4.5.1.6
Extern
alarm
If
the
unit
has
been
connected
to
an
external
humidity
sensor
or
motion
sensor.
Use
the
D2
connector
on
top
of
the
unit.
(See
page
23
in
this
manual).
Note
!
In
order
for
this
feature
to
work,
you
need
the
one
‐
pole
switch
marked
RH%
ON
/
OFF
inside
the
unit
to
be
set
in
position
1.
(See
page
2
of
this
manual
for
the
location
of
this
switch).
Supply
and
Extract
air
should
have
the
same
value
as
the
MAX
value
under
4.5.1.3
(Set
to
100%
from
factory.)
4.5.1.7
Absent
Menu
for
setting
the
desired
values
by
activating
away
/
home
function.
Use
the
D3
connector
on
top
of
the
unit.
(See
page
23
in
this
manual)
Function
is
operated
via
an
external
switch.
Set
value
of
the
desired
temperature
will
show
in
the
display
after
activating
the
function.
4.5.1.8
Calibration
Menu
reading
of
embedded
temperature
sensors.
These
temperature
sensors
are
delivered
calibrated
from
the
manufacturer
and
should
not
be
attempted
change
in
here.
The
«Outside
air»
sensor
normally
shows
3
‐
6°C
highter
temperaature
then
the
reel
outside
temperature.
This
is
due
to
heating
of
the
air
in
the
duct
network
from
the
intake
grille
to
the
intake
of
the
unit
where
the
sensor
are
placed.