PARAMETERS:
SENS-potentiometer: Setting minimum light level (dimming level)
•
5 % potentiometer to MIN (factory setup)
•
20 % potentiometer to MAX
LUX-potentiometer: Setting maximum light level
•
80 % potentiometer to MIN
•
100 % potentiometer to MAX (factory setup)
TIME-potentiometer: Setting after-glow time
•
1 hour potentiometer to MIN
•
Always ON potentiometer to MAX (factory setup)
5.2 Changing adjustments:
SENS
The SENS potentiometer permits adjustment of the sensitivity of the
sensor to movement. Note that also the sensor’s detection area may be
altered.
TEST
Turning the SENS potentiometer moves the sensor in the test mode.
This test mode lasts for 3 minutes from the last adjustment of the SENS
potentiometer. In the test mode the green and red LEDs flash alternately.
In the test mode the detection area can be tested by walking across in
front of the sensor, causing the light fitting to switch on in response to the
movement for approx. 5 seconds. The sensitivity during a test will be at the
level indicated on the SENS potentiometer. After switch off there is a delay
of approx. 2 seconds before switching on again.
TIME
The TIME potentiometer enables the length of time the light remains
on after the sensor’s last reaction to movement to be adjusted. The horizontal
arrow points to 1 minutes. The setting range is 1 min - 30 min.