Timing Menu
The Timing controls adjust the timing of the HD SDI or SD SDI and composite output of Mitto with
respect to the reference input. If you set all three of the timing controls (Vertical, Horizontal, Fine
Phase) to zero, then Mitto’s output will be in exact time with the reference.
If, for example, you need to have Mitto’s output be one line early with respect to the reference in order
to auto-time properly into a production switcher, set the Vertical Timing to -1.
You can change these values by clicking and dragging on the slider control, by using the up and down
arrow buttons, or by entering values directly into the fields.
• Vert Timing – Set the vertical timing in lines. (range is -1000 to 1000 lines, default is 0).
• Hor Timing – Set the horizontal timing in clocks. (range is -2000 to 2000 clocks, default is 0).
• Fine Phase – Set the fine phase timing in nanoseconds to color time the composite output.
(range is -35 to 35 nsec, default is 0).