TROUBLESHOOTING

Contact Enphase Customer Support (

enphase.com/en-us/support/contact

) if you have any questions about troubleshooting your system.

a

 

LED overview

LED

State

Description

All

Flashing amber in unison

The IQ Envoy is booting up

Flashing green sequentially 

Software upgrade in progress

Network communications

Solid green

Communicating with Enlighten

Flashing green

WPS connection in progress, or IQ Envoy is attempting to connect to Enlighten

Solid amber

Local network connection only

Off

No network connection

AP mode

Solid green

AP mode enabled: IQ Envoy Wi-Fi network available

Off

AP mode disabled: IQ Envoy Wi-Fi network unavailable

Power production

Solid green

All communicating microinverters are producing

Flashing green

Microinverter upgrade in progress

Solid Amber

At least one microinverter is not producing

Off

Microinverters are not communicating (low light or night time)

Device communications

Solid Green

All devices are communicating

Flashing Green

Device scan in progress

Solid Amber

At least one device is not communicating

Off

Devices are not communicating (low light or night time)

b

 

Device detection issues

If the Device Communications LED 

 lights solid amber, it may be a 

result of low light levels. If there isn’t enough sunlight to power up the 

microinverters, they can’t communicate with the Envoy.
If there is sufficient daylight for the microinverters to power up, the issue 

may be that the Envoy is having difficulty communicating over the power 

lines. To troubleshoot this issue: 

•  Check the Installer Toolkit mobile app to see which devices are not 

communicating. 

•  Check that the circuit breaker(s) in the IQ Combiner 3C-ES for the PV 

array are in the “ON” position. 

•  Verify that the PV modules are connected to the microinverters. 
•  Verify the PV module DC voltage is within the allowable range for the 

microinverter.

•  For connection issues related to Encharge/Enpower, ensure that you 

have performed Range test to make sure that all the devices are in 

the communication range.

c

 

Power production issues

If the Power Production LED   lights solid amber, check the Installer Toolkit 

mobile app to see which microinverters are not producing:

•  If no microinverters are producing power, there may be a grid or wiring 

issue. First, verify that there is proper input voltage and frequency from 

the utility. Next, check the breaker and wiring, starting at the load center.

•  If all of the non-productive microinverters are on the same branch, 

check the breaker and wiring starting at the junction box for the affected 

branch.

•  If only one or scattered microinverters are not producing power, first 

check to see that the AC connectors are fully seated. Next, check that 

each module is providing the required startup voltage for the microin-

verter (22V). A PV module that is failing or that is undersized may not 

generate enough power for AC conversion.

d

 

Internet connection issues

If you are using Wi-Fi and the Network Communications LED 

 remains off or 

solid amber:

•  The WPS connection window may have timed out. Retry the connection steps.

•  Make sure that the broadband router is connected and operational by 

checking that other devices at the site can access the network. 

•  Check for metal enclosures or obstructions that may be impeding wireless 

communication. 

•  If you don’t see your router/access point in the list on the Envoy, or cannot 

maintain a connection, you may need to add a wireless repeater to extend 

the network range.

If you are using the Enphase Mobile Connect modem and the Network Com-

munications LED remains off or lights solid amber, see Troubleshooting in the 

Enphase Mobile Connect Installation Guide.

If you replace your router, configure the IQ Envoy Wi-Fi settings for the new Wire-

less Network Name (SSID) and password, or use the WPS function described in 

Installation Step 10.

e

 

Loss of AC to a single branch of microinverters

If a single branch of microinverters is not producing, it may indicate loss of AC 

to the branch. 

•  Use a multi-meter set to AC to test the breaker lugs. The result should be 

around 240 VAC.

•  If not, switch the breaker off and on to reset. 

f

 

Inoperable IQ Envoy (all LEDs off)

If the IQ Envoy is not receiving power, all LEDs will be off. 

•  Use a multimeter set to AC to test line 1 on the Envoy breaker to the AC 

neutral busbar. The result should be around 120 VAC.

g

 

Inoperable IQ Envoy and no AC to branch

If a branch of microinverters is not producing and the IQ Envoy LEDs are off: 

•  Test at the main lugs for L-L and L-N voltages. The results should 

be around 240 VAC and 120 VAC respectively. If not, there may be a 

problem with the wiring from the panel.

Summary of Contents for IQ Combiner 3C-ES

Page 1: ... Press to enable IQ Envoy s AP Mode for connecting with a mobile device Hold for 5 seconds to start WPS connection to a router Power Production LED Green when microinverters are producing power Device Communications LED Green when devices are communicating with IQ Envoy Device Scan Button Press to start stop 15 minute scan for devices over the power line Track system installation progress with the...

Page 2: ...ou will typically use up to four 20 A breakers Refer to the diagram on the door of the IQ Combiner and do the following A Use copper conductors sized to meet local code requirements and voltage drop rise considerations B Bring in the wires from each AC branch circuit C Connect the ground green or green yellow to the ground busbar D Pass the L1 conductors from each PV branch circuit through the pro...

Page 3: ...o not install CTs when cur rent is flowing in the sensed circuit Always install CT wires in the terminal blocks before energizing the sensed circuit Load Center To Grid From IQ Combiner IQ Envoy Terminal Block Relay contacts if needed UP TO 250 Vac 100A 0 5V 45 66Hz white blue Not used white blue P1 C1 C2 1 2 3 4 NO Ref Common C Digital Input Relay PD B300 OVC II L1 L2 N CU 75C 14AWG MIN MEAS CAT ...

Page 4: ...nd tap Envoy connectivity D Make sure that the Envoy is connected to your mobile device verify the network configuration view the cellular connection status 8 INSTALLATION Part 2 You must complete Installation Part 2 AFTER installing any Enphase Microinverters Enphase Encharge and or Enphase Enpower Detect Devices A Turn on the DG breaker s B Use one of the following methods to detect devices Meth...

Page 5: ... right corner C When you have access to a computer log in to Enlighten and select the system name from the Activation List on the dashboard D From the activation form open Array Builder If you used Installer Toolkit to build arrays and scan device serial numbers the array s are built Make any necessary adjustments in Array Builder If you did NOT use Installer Toolkit to build arrays and scan devic...

Page 6: ...ng power there may be a grid or wiring issue First verify that there is proper input voltage and frequency from the utility Next check the breaker and wiring starting at the load center If all of the non productive microinverters are on the same branch check the breaker and wiring starting at the junction box for the affected branch If only one or scattered microinverters are not producing power f...

Page 7: ...e radio exempt from licensing The operation is permitted for the following two conditions 1 the device may not cause harmful interference and 2 the user of the device must accept any interference suffered even if the interference is likely to jeopardize the operation Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est au...

Page 8: ...ombiner 3 ES only for serving Enphase equipment No other loads are allowed FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequenc...

Reviews: