Connect the Cable to the AC Junction Box

Connect the Engage Cable into the AC branch circuit  
junction box. 

See notes in 

Step Details

.

10

Set Up and Activate System Monitoring

Referr to the 

Envoy-S Quick Install Guide

 or the  

Envoy-S Installation and Operations Manual 

to install 

the Envoy-S and set up system monitoring.

After you have installed the microinverters, the  
high-level steps to complete the PV installation are:

a. 

Connect the Envoy-S.

b. 

Detect the microinverters.

c. 

Connect to Enlighten.

d. 

Register the system.

e. 

Build the virtual array.

Follow the procedures in the 

Envoy-S Quick Install 

Guide

 or the 

Envoy-S Installation and Operations 

Manual

 to activate system monitoring and complete 

the PV installation.

11

status LED

Connect the PV Modules

a. 

Mount the PV modules above the microinverters.

b. 

Connect the DC leads of each PV module to the 
DC input connectors of the corresponding micro-
inverter.

c. 

Check the LED on the side of the microinverter. 

The LED flashes six times at start up. All green 

flashes indicate normal start up.  

This table lists microinverter LED status for normal  
operation after startup. 

LED

Indicates

Flashing green

Normal operation. AC grid function is 
normal and there is communication with 
the Envoy-S.

Flashing 
orange

The AC grid is normal but there is no  
communication with the Envoy-S.

Flashing red

The AC grid is not within specification.

Solid red

There is an active DC ground resistance 
fault.

Energize the System

a. 

If applicable, turn ON the AC disconnect or circuit 

breaker for the branch circuit.

b. 

Turn ON the main utility-grid AC circuit breaker. 

 

Your system will start producing power 

after a  

five-minute wait time. 

Summary of Contents for Enphase S Series

Page 1: ... is correct and that none of the AC or DC wires are pinched or damaged Ensure that all AC junction boxes are properly closed WARNING Risk of electric shock Risk of fire Do not exceed the maximum number of microinverters in an AC branch circuit as listed in this guide You must protect each microinverter AC branch circuit with a 20A maxi mum breaker WARNING Do not connect Enphase Microinverters to t...

Page 2: ...sk of electric shock Risk of fire Do not leave AC connectors on the Engage Cable uncovered for an extended period If you do not replace the microin verter immediately you must cover any unused connec tor with a sealing cap Sealing caps may not be reused WARNING Risk of electric shock Risk of fire Make sure protective sealing caps have been installed on all unused AC connectors Unused AC connectors...

Page 3: ...oy S Enphase Installer Toolkit mobil app optional but strongly recommended Engage Cable single phase 240 VAC or three phase 208 VAC Cable clips Sealing caps as needed for any unused drops on the Engage Cable Terminators as needed one needed at the end of each AC branch circuit Enphase disconnect tool Other Items Outdoor rated weather proof AC junction box es Gland or strain relief fitting one per ...

Page 4: ...tall the microinverter as shown with the contoured side up Failure to do so could allow the microinverter to come in contact with the PV module back sheet Dress the Cable a Use cable clips or tie wraps to attach the cable to the racking b Dress any excess cabling in loops so that it does not contact the roof Do not form loops smaller than 4 75 inches 12 cm in diameter Keep the drop connector relea...

Page 5: ...and connect the microinverter Listen for two clicks as the connectors engage b Cover any unused connectors with Enphase Sealing Caps Listen for two clicks as the connec tors engage See notes in Step Details c Attach the terminated cable end to the PV racking with a cable clip or tie wrap WARNING Install sealing caps on all unused AC connectors as these become live when the system is energized by t...

Page 6: ...s LED Connect the PV Modules a Mount the PV modules above the microinverters b Connect the DC leads of each PV module to the DC input connectors of the corresponding micro inverter c Check the LED on the side of the microinverter The LED flashes six times at start up All green flashes indicate normal start up This table lists microinverter LED status for normal operation after startup LED Indicate...

Page 7: ...C SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED WARNING Allow a minimum of 1 9 cm 0 75 between the roof and the microinverter Also allow 1 3 cm 0 50 between the back of the PV module and the top of the microinverter NOTE Torque the microinverter fasteners to the values shown Do not over torque 1 4 mounting hardware 5 N m 45 50 in lbs 5 16 mounting h...

Page 8: ... to Enphase Click Add a New System at https enlighten enphaseenergy com Use this map to build the virtual array in Enlighten s Array Builder DOCUMENT NUMBER ENPHASEENERGY COM INSTALLATION MAP REVISION 140 00003 04 A B C D E F G H J K L M 1 2 3 4 5 6 7 To Sheet ________ To Sheet ________ To Sheet ________ To Sheet ________ Envoy Serial Label ...

Reviews: