Section 15
00-02-0831
2013-03-21
-
5 -
Single Magneto Shutdown
–
Wiring of magneto to Normally
Open (NO) switch terminal shuts
engine down at a pre-determined
high level (Shown at right). Wire
to Normally Closed (NC) terminal
to shutdown on low level.
Dual Magneto Shutdown
–
Shutdown dual magneto engines
using a Murphy MS2120
Magnetic Switch. Diagram at
right shows hookup for low-level
shutdown. Wiring changes and
mounting locations are
necessary for high-level
shutdowns.
1-800-548-1191 - http://www.partdeal.com - [email protected]