Section 40

 

00-02-1150

 

2018-10-08 

Troubleshooting 

Murphy CONNECT has Wi-Fi communications which allows for minor troubleshooting of the 

module. This section details the how to log on and interpret the data. 

 

To access the Wi-Fi for troubleshooting ensure the device has the appropriate power to the 

unit. When the unit is powered on the unit can be found by searching for a new Wi-Fi 

connection on the PC or smart device. 

 

Wi-Fi Address: CONNECT_xxxx (the xxxx represent the last 4 digits of the MAC address of the 

device connecting) 

Password: Murphy (use Murphy only when required to login) 

 

Once connected to the device Wi-Fi network, open the browser and type in 192.168.6.1 into 

the URL address to access the modem’s page (also shown on the CONNECT front label). The 

page should resemble the image below and allow one to see the items listed below for 

troubleshooting hardware and connectivity.  

 

Application: States whether the application is running or not running. This should be running at 

this stage 

Version: Version of the CONNECT device 

Connection: States whether the device is connected to a cellular network 

Serial Number: Provides Serial Number of device. (Used to register device if device is 

installed) 

IMEI: Provides IMEI of device. (Used to register device if device is installed) 

SIM: Provides SIM number. 

Cell Signal: Provides range for cellular network. (0-6 = Poor, 7-15 = Okay, 15+ = Good) 

GPS: States whether Locked or not locked for GPS positioning. 

Satellites: 1-2 will not allow a lock for GPS, 3+ allow locking for GPS location. 

Latitude: Once GPS is locked, provides Latitude coordinates for last known location. 

Longitude: Once GPS is locked, provides Longitude coordinates for last known location. 

Summary of Contents for Murphy CONNECT

Page 1: ...00 02 1150 Section 40 2018 10 08 Murphy CONNECT Installation Manual Initial Release for U S Only ...

Page 2: ...ian install the unit and make sure the installation conforms to local codes including but not limited to double insulation and fire containment Observe all Warnings and Cautions in each section of these instructions The Murphy CONNECT product is a telemetry product designed for use in industrial environments for remote monitoring and control when used with Murphy s PowerCore family of controllers ...

Page 3: ...ware Installation 5 Inspecting Package Contents 5 Installation 5 Preparation 5 Installing the Module 5 Dimensions for Installation 6 Wiring Instructions 8 PIN Specifications for 8 Position Amphenol Connection 8 Accessories 10 Specifications 10 Electrical 10 Environmental 10 Mechanical 10 ...

Page 4: ... remotely starting an engine when used in conjunction with Murphy s PowerCore controllers Please be cognizant at all times of hands and other objects that are in close proximity to the machine s being controlled as they may commence operation suddenly and without warning ...

Page 5: ...spect each item for damage which sometimes occurs during shipping The items included in the box are Murphy CONNECT Telemetry Module P N 40 70 0525 includes CONNECT Module Dual Antenna with GPS and Cellular 3 meter 9 84ft length Quick Start Guide Installation Preparation Determine the location of where the CONNECT module will be installed Ensure there is proper room for the module to be mounted and...

Page 6: ...Section 40 6 00 02 1150 2018 10 08 Dimensions for Installation Murphy CONNECT Module Inches mm ...

Page 7: ...Section 40 7 00 02 1150 2018 10 08 Dimensions for Installation Antenna Inches mm ...

Page 8: ...codes When the accessory harness is used the PowerCore controller in the panel will need the I O established prior to use TEC 10 and ML1000 Set the Digital Output 2 function to Ignition On On in Standby ML2000 Set the Digital Output 4 function to Ignition On On in Standby NOTE If the application is left in Auto mode a battery maintaining system should be installed for possible battery drain due to...

Page 9: ...NECT front label The page should resemble the image below and allow one to see the items listed below for troubleshooting hardware and connectivity Application States whether the application is running or not running This should be running at this stage Version Version of the CONNECT device Connection States whether the device is connected to a cellular network Serial Number Provides Serial Number...

Page 10: ...us RTU Wi Fi 2 4 GHz 802 11 b g n Troubleshooting Cellular LTE GPS Location Services Connection CONNECT Connector Amphenol AT06 08S Mating Connector Amphenol AT04 08PA Deutsch DT04 08PA Inputs 1 1 Digital Inputs Future Use Shared with Digital Output Outputs 1 1 Digital Output Future Use Shared with Digital Input Environmental Operating Temperature 30 C to 80 C 22 F to 176 F Storage Temperature 30 ...

Page 11: ......

Reviews: