2.5
Input signals
PTM 535Z data transmits telegrams indicating the status of the following input signals:
ECO 200 action direction (press or release)
Press indicates a move away from the PCB (and the ECO 200 contacts)
Release indicates a move towards the PCB (and the ECO 200 contacts)
On-board meander contact (M1)
This meander contact is intended for use with a conductive rubber button and is consid-
ered to be active if it is closed.
Contact EnOcean for reference on suitable rubber contact mats if required.
External input signals (IN1 and IN2)
PTM 535Z provides and internal pull-up resistor on these signals.
These inputs are considered active if they are connected to Ground (GND).
2.5.1
PTM 535Z input status encoding
Table 2 below shows the encoding used by PTM 535Z.
Input 2 (IN2)
Input 1 (IN1)
Meander (M1) ECO 200
Command
0 = Not Connected to GND
1 = Connected to GND
0 = Open
1 = Closed
Press= Move away from PCB
Release = Move towards PCB
0
0
0
Release
0x23
0
0
0
Press
0x22
0
0
1
Release
0x12
0
0
1
Press
0x13
0
1
0
Release
0x14
0
1
0
Press
0x15
0
1
1
Release
0x16
0
1
1
Press
0x17
1
0
0
Release
0x18
1
0
0
Press
0x19
1
0
1
Release
0x1A
1
0
1
Press
0x1B
1
1
0
Release
0x1C
1
1
0
Press
0x1D
1
1
1
Release
0x1E
1
1
1
Press
0x1F