USER MANUAL PREVIEW
PTM 535BZ
–
BLUETOOTH AND ZIGBEE GREEN POWER PUSHBUTTON TRANSMITTER
© 2021 EnOcean | www.enocean.com
F-710-017, V1.0
PTM 535BZ User Manual | v1.0 | May 2021 | Page 34/112
4.4.1.2
Device ID 0x07: Generic 8-contact Switch
Device ID 0x07 (Generic 8-contact Switch) is the default configuration used by PTM 535BZ
when transmitting ZGP data telegrams.
below illustrates the ZGP command struc-
ture used by generic switch data telegrams.
Figure 27
–
ZGP payload structure for Device ID 0x07
Within this structure, the ZGP Command encodes the action of the ECO 200 harvester con-
nected to PTM 535BZ (Press or Release) as described in
Chapter 2.4.1
The default behaviour is that a press action (ZGP command 0x69) is a move of the ECO 200
spring away from the PCB and a release action (ZGP command 0x6A) is a move of the ECO
200 spring towards the PCB.
This default behaviour can be inverted using the NFC interface if required (so that a press
action would be a move of the ECO 200 spring towards the PCB and a release action would
be a move of the ECO 200 spring away from the PCB).
The Button Status field following the 0x69 / 0x6A ZGP Command encodes the status of the
input signals INPUT1 and INPUT2 as defined by the ZGP specification
below shows the resulting encoding of PTM 535BZ for Device ID 0x07.
INPUT2
INPUT1
ECO 200
ZGP Command Button Status
Not connected
Not connected
Press action
0x69
0b00000001
Not connected
Not connected
Release action
0x6A
0b00000001
Not connected
Connected
Press action
0x69
0b00000010
Not connected
Connected
Release action
0x6A
0b00000010
Connected
Not connected
Press action
0x69
0b00000100
Connected
Not connected
Release action
0x6A
0b00000100
Connected
Connected
Press action
0x69
0b00000110
Connected
Connected
Release action
0x6A
0b00000110
Table 7
–
ZGP command and button status encoding for Device ID 0x07