Usually a sensor has only one assigned profile. In case of PTM Modules (RPS Profiles) the
receiver can decide in some cases which profile he chooses for interpretation of the data
from the very same PTM module.
Normal Mode
Secure Mode
ERP 1
(PTM 210, PTM 215)
F6-01-01
F6-02-01
F6-02-02
F6-02-03
F6-04-01
D2-03-00
ERP 2
(PTM 215J, PTM 215U)
F6-02-04
F6-04-02
D2-03-00
TCM 515U and TCM 310U does convert from ERP2 profiles to EPR1 profiles inter-
nally. On the ESP3 interface the commands they look like “ERP1”.
Due to the mechanical hysteresis of the energy bow, in most rocker switch de-
vice implementations, pressing the rocker sends an N-message and releasing the
rocker sends a U-message!
For the normal mode profiles (Starting with F6) there is no EEP Teach-in message send. For
secure mode profile (starting D2) there is Secure Teach in. See secure teach in chapter
3.2.3 for details.
Note that PTM 21x in will not send a data telegram when pressing 2, 3 or 4 nib-
ble SBC and actuating the energy bow. This button combination is reserved for
mode change. Please see chapter 3.3 for details.