9.5.22
SOLAR_THRESHOLD
If reduction of the reporting interval based on the solar cell light level has been enabled
then the light level threshold is defined by SOLAR_THREHOLD register as shown in Figure
54 below.
SOLAR_THRESHOLD (Default Setting: 0x00C8)
Bit 15
Bit 14
…
Bit 1
Bit 0
SOLAR CELL THRESHOLD
Figure 54
–
SOLAR_THRESHOLD register
The encoding used by the SOLAR CELL THRESHOLD bit field is shown in Table 40 below.
SOLAR CELL THRESHOLD
Threshold
0x0000
0 lux (minimum setting)
…
…
0x00C8 (Default)
200 lux seconds (default setting)
…
…
0xFFFF
65535 lux (maximum setting)
Table 40
–
SOLAR CELL THRESHOLD bit field encoding
The default setting for the solar cell threshold is 200 lux which corresponds to good availa-