EL-300 Quick Install Guide
AC Connection
Take the AC cable and connect it to EL-300 micro inverter’s AC connectors.
Listen for a “click.” The click sound indicates that the AC connection is firmed.
Install an AC grid cable to the other end of the micro inverter circuit string,
prepare for step 6.
After all micro inverters are installed and connected, please seal unused AC
connectors with end caps. Please also address the excess AC cabling to avoid it
from hanging loosely or contacting the roof.
Note: AC disconnection tool is required for disconnecting the AC connectors.
Please do NOT unplug them without using the AC disconnection tool.
!
!
Note: MC4 pin extractor is required for disconnecting the DC connectors.
Please do NOT unplug them without using the pin extractor.
AC Cable
AC Connector
End Cap
DC Connector
DC Connection
Mount the PV modules above the EL-300 micro inverters.
After all PV modules are installed, completely cover the PV modules to prevent them
from producing electricity.
Connect the DC connectors from PV modules to the DC input connectors on EL-300
micro inverter.
3