Diagnostic Messages 

Message Meaning 

Action Required 

 

No message on display. 
Power has been cut off to the Spa. 

The control panel will be disabled until power returns.  

-- 

Temperature unknown. 

After the pump has been running for 2 minutes, the 
temperature will be displayed. 

PR 

System is priming.  (Spa must be filled to 
proper level.  Water should be at least 
halfway up the skimmer.)                                   

Spa is powering up.  This operation takes 6 minutes total.  
After 4 minutes, “- -” will appear for two minutes.  The 
spa then enters it’s first filter cycle and is now available 
for setting. 

HH 

“Overheat”  The spa has shut down.  Sensors 
detect 118

°

F at the heater. 

DO NOT ENTER THE WATER.  Remove the spa cover 
and allow the water to cool.  Once the heater has cooled, 
reset by pushing any button.  If the spa does not reset, shut 
off the power to the spa and call your dealer or service 
organization. 

OH 

“Overheat”  The spa has shut down.  Sensors 
detect spa water is 110

°

F. 

DO NOT ENTER THE WATER.  Remove spa cover and 
allow water to cool.  At 107

°

F, the spa should 

automatically reset.  If the spa does not reset, shut off 
power to the spa and call your dealer or service 
organization. 

IC 

“Ice” 

 

Potential 

freeze 

condition 

detected 

No action required.  The pump and blower will 
automatically activate regardless of spa status. 

SA 

Spa is shut down.  The sensor that is plugged 
into the Sensor “A” jack is not working. 

If the problem persists, contact your dealer or service 
organization.  (May appear temporarily in an overheat 
situation and disappear when the heater cools) 

SB 

Spa is shut down.  The sensor that is plugged 
into the Sensor “B” jack is not working. 

If the problem persists, contact your dealer or service 
organization.  (May appear temporarily in an overheat 
situation and disappear when the heater cools) 

SN 

Sensors are out of balance.  If changing spa 
temperature it may just be temporary.  If 
flashing by itself, the spa is shut down. 

If the problem persists, contact your dealer or service 
organization 

HL 

A significant difference between temperature 
sensors has been detected.  This could 
indicate a flow problem. 

Check the water level in spa.  Refill if necessary.  If the 
water level is okay, make sure the pumps have been 
primed.  If problem persists, contact your dealer or service 
organization. 

LF 

Persistent low flow problems.  (Displays on 
the fifth occurrence of the “HL” message 
within 24 hours.)  Heater is shut down, but 
other spa functions continue to run normally. 

Follow the action required for “HL” message.  Heating 
capability of the spa will not reset automatically, you may 
press any button to reset. 

DR 

Possible inadequate water, poor flow, or air 
bubbles detected in heater.  Spa is shut down 
for 15 minutes. 

Check water level in spa.  Refill if necessary.  If the water 
level is okay, make sure the pumps have been primed.  
Press any button to reset, or this message will 
automatically reset within 15 minutes.  If the problem 
persists, contact your dealer or service organization. 

DY 

Inadequate water detected in heater. 

 

(Displays on the third occurrence of “DR” 
message).  Spa is shut down. 

Follow action required for “DR” message.  Spa will not 
automatically reset.  Press any button to reset. 

 
 

 
WARNING!  SHOCK HAZARD!  NO USER SERVICABLE PARTS. 
Do not attempt service of this control system.  Contact your dealer or service organization for assistance.  Follow all 
owner’s manual power connection instructions.  Installation must be performed by a licensed electrician and all grounding 
connections must be properly installed. 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for VS500 Spa Pak

Page 1: ... spa We think it is important for you to take a few moments and get acquainted with your new spa operation Please keep this manual available for references QCA Spas would like to congratulate you on your purchase and we sincerely hope you enjoy your QCA Spa SERIAL NUMBER _____________ 18 DIGIT SPA NUMBER ____________ DreamSeriesManual VS500 501 1 07 ...

Page 2: ... 3 Initial Start Up 5 Installation Instructions 4 115 230v Installations 4 Prevention of Freezing 9 Refilling your Spa 7 Removing the Box Filter Cartridge 8 Spa and Cabinet Maintenance 9 Spa Location 4 Spa Top Side Control 5 Troubleshooting 9 UL Instructions 3 Vacation Care 8 Warranty Information 10 11 Water Care Program 7 8 Winterizing 9 ...

Page 3: ...es to 100 F 38 C c Before entering a spa or hot tub the user should measure the water temperature with an accurate thermometer since the tolerance of water temperature regulating devices may vary as much as 5 F 3 C d The use of alcohol drugs or medication before or during spa or hot tub use may lead to unconsciousness with the possibility of drowning e Persons suffering from obesity or with a medi...

Page 4: ... Installation Instructions Electrical General Prior to performing any service to the spa package turn OFF ALL primary electric power at the main circuit breaker or disconnect panel Opening the front cover of the electrical control box can make all field electrical connections All electrical connections to this spa package must be accomplished by a qualified electrician in accordance with the Natio...

Page 5: ... the light automatically turns off after four hours Preset Filter Cycles The first filter cycle begins six minutes after the spa is energized The second filter cycle begins 12 hours later Filter duration is programmable at the Master Control Pad for 2 4 6 8 hours or for continuous filtration indicated by FC The default filter time is two hours To program press Temp then Jets Press Temp to adjust P...

Page 6: ...ntact your dealer or service organization May appear temporarily in an overheat situation and disappear when the heater cools SN Sensors are out of balance If changing spa temperature it may just be temporary If flashing by itself the spa is shut down If the problem persists contact your dealer or service organization HL A significant difference between temperature sensors has been detected This c...

Page 7: ...ng of the Water Simply siphon water from spa with garden hose A sump pump may be used to pump water from spa Use a wet dry vac to remove the remaining amount of water Refilling your Spa 1 Be sure the main breaker to your spa equipment pack is off 2 Fill spa with water to proper level 3 Turn power back on spa will automatically start to run and heat water to set temperature Your Water Care Program ...

Page 8: ...he spa water may freeze Any damage to the spa from freezing which is a direct cause of poor maintenance will not be covered by warranty Removing a Box Filter Cartridge The cartridge of the in line filter must be removed for cleaning This is accomplished as follows for box filter 1 Remove filter lid 2 Twist and lift built in chemical dispenser to reveal the cartridge 3 Remove the filter cartridge f...

Page 9: ...ment such as the amount of light or humidity will determine how often repeat applications are required Consult your local hardware store for wood finishing products and their proper application Weather Guard Cabinet Care Handcrafted maintenance free cabinet surfaces may need to be wiped down from time to time with a soap and water solution or simply sprayed with a garden hose Use of harsh chemical...

Page 10: ...chased Date Installed Dealer Address Telephone Spa Model Serial Number Warning Elderly persons infants and anyone subject to heart disease diabetes high or low blood pressure strokes epilepsy or similar afflictions should not enter a spa alone and without consulting a physician Unsupervised use by children should be prohibited Never use a spa while under the influence of alcohol anti coagulants an...

Page 11: ... gift to help maintain your spa and to VALIDATE your spa warranty return the PREPAID registration card below within the next THIRTY days To immediately register your new spa you may log onto our web site at qcaspas com 11 ...

Reviews: