Englefield QUICK-FIT SHOWER TRAY Installation Instructions Download Page 3

TIMBER
When installed on a timber floor, the floor board should be supported at not greater than 500mm centres
and the cut-out waste connection kept to a minimum.

CONCRETE
When installed on a concrete slab floor, chases or channels left for plumbing must be completely backfilled.

B) FLOOR CONSTRUCTION

1)  Ensure that the wall framing and lining are constructed in accordance with one of the following
      illustrations (Fig. 4 or 5).

2)  Measure the back and side wall(s). The dimensions of the shower area (measured to the finished
      surface of the wall board) must be as shown below. This is particularly important for Alcove (3-sided)
      installations where an Englefield Duracryl  wall will be installed.

3)  Ensure studs are located as shown (dimensions A,B & C) to provide a solid support for the door and
      return panels.

C) WALL CONSTRUCTION

INSTALLATION INSTRUCTIONS

QUICK-FIT SHOWER TRAY

-3-

®

Fig. 4 - Corner (2 sided) Wall

Fig. 5 - Alcove (3 sided) Wall

B

+2

 -0

D

+2

 -0

C

+2

 -0

C

D

SHOWER TR AY

884

1164

900 X 1200 X 900

750 X 900 X 750

739

864

984

964

1000 X 1000 X 1000

884

864

900 X 900 X 900

900 X 750 X 900

885

747

A

+2

 -0

A

B

SHOWER TRAY

984

984

1000 X 1000

884

884

900 X 900

900 X 750 *

734

884

884

1184

1200 X 900 *

* Asymmetric trays are handed, eg: 900x750 Right = 750x900 Left

Dimensions are to the finished surface of the wall board

Summary of Contents for QUICK-FIT SHOWER TRAY

Page 1: ...afe Tray 60mm sill height The tray should be installed in accordance with one of the following recommended methods Fig 1 2 or 3 A SHOWER TRAY ENGLEFIELD DURACRYL WALL TILED WALL INSTALLATION OPTIONS WET AREA WALL BOARD 9 10mm SIKA SHOWERBOND ADHESIVE DURACRYL WALL SIKASIL NG SILICONE SEALANT Fig 1 Wet Area Wall Board Englefield Duracryl Wall TH Install Duracryl Shower Wall as per installation inst...

Page 2: ...ION INSTRUCTIONS QUICK FIT SHOWER TRAY Wall retainer extrusions or door must be installed prior to tiling Please refer to installation instructions provided with shower door IMPORTANT 2 Fig 3 Wet Area Wall Board Tiles Method 2 TILES max 10 mm GROUT TILE ADHESIVE SILICONE SEALANT WATERPROOFING MEMBRANE WET AREA WALLBOARD max 6mm 50 mm REBATE 10 12 mm 5 mm GAP WET AREA WALL BOARD 9 10 mm TILES GROUT...

Page 3: ...ust be as shown below This is particularly important for Alcove 3 sided installations where an Englefield Duracryl wall will be installed 3 Ensure studs are located as shown dimensions A B C to provide a solid support for the door and return panels C WALL CONSTRUCTION INSTALLATION INSTRUCTIONS QUICK FIT SHOWER TRAY 3 Fig 4 Corner 2 sided Wall Fig 5 Alcove 3 sided Wall B 2 0 D 2 0 C 2 0 C D SHOWER ...

Page 4: ... turn tray over and place into position Ensure that the tray is level 3 Leave the tray in place do not stand or walk on it for 24 hours to allow enough time for adhesive to cure B CONSTRUCTION ADHESIVE Shower tray must be installed level Tray must be fully supported IMPORTANT Failure to comply voids warranty CONTACT AND WARRANTY INFORMATION INSTALLATION SHOWER WASTE NEW ZEALAND KOHLER NZ LTD www e...

Reviews: