background image

 

30 

 

PLEASE

 

NOTE:

 

EPA

 

INFORMATION

 

The

 

following

 

additions

 

to

 

your

 

owner’s

 

manual

 

will

 

enable

 

you

 

to

 

achieve

 

optimal

 

emissions

 

performance

 

from

 

your

 

stove.

  

Important

 

safety

 

tips

 

are

 

also

 

included.

 

 

Proper

 

Installation

 

 

Please

 

refer

 

to

 

the

 

Installation

 

section

 

of

 

your

 

owner’s

 

manual

 

and

 

follow

 

the

 

guidelines

 

listed

 

therein

 

for

 

safety

 

and

 

for

 

optimal

 

emissions

 

performance.

 

Additional

 

information:

  

Venting

 

Introduction:

  

Draft:

 

Draft

 

is

 

the

 

force

 

which

 

moves

 

air

 

from

 

the

 

appliance

 

up

 

through

 

the

 

chimney.

 

The

 

amount

 

of

 

draft

 

in

 

your

 

chimney

 

depends

 

on

 

the

 

length

 

of

 

the

 

chimney,

 

local

 

geography,

 

nearby

 

obstructions

 

and

 

other

 

factors.

 

Too

 

much

 

draft

 

may

 

cause

 

excessive

 

temperatures

 

in

 

the

 

appliance

 

and

 

may

 

damage

 

the

 

catalytic

 

combustor

.

 

Inadequate

 

draft

 

may

 

cause

 

backpuffing

 

into

 

the

 

room

 

and

 

‘plugging’

 

of

 

the

 

chimney

 

or

 

the

 

catalyst

.

 

Inadequate

 

draft

 

will

 

cause

 

the

 

appliance

 

to

 

leak

 

smoke

 

into

 

the

 

room

 

through

 

appliance

 

and

 

chimney

 

connector

 

joints.

 

An

 

uncontrollable

 

burn

 

or

 

excessive

 

temperature

 

indicates

 

excessive

 

draft.

 

Please

 

be

 

mindful

 

of

 

installation

 

location:

 

Inversion

 

and

 

other

 

air

 

quality

 

issues

 

can

 

arise

 

in

 

valleys

 

or

 

if

 

unit

 

is

 

installed

 

close

 

to

 

neighboring

 

homes.

 

This

 

wood

 

stove

 

operates

 

on

 

a

 

natural

 

draft

 

system,

 

in

 

which

 

the

 

chimney

 

system

 

pulls

 

air

 

through

 

the

 

stove.

 

This

 

unit

 

must

 

be

 

installed

 

in

 

accordance

 

with

 

the

 

following

 

detailed

 

descriptions

 

of

 

venting

 

techniques;

 

not

 

installing

 

the

 

stove

 

in

 

accordance

 

with

 

the

 

details

 

listed

 

here

 

can

 

result

 

in

 

poor

 

stove

 

performance,

 

property

 

damage,

 

bodily

 

injury

 

or

 

death.

 

Avoid

 

make

shift

 

compromises

 

when

 

installing

 

the

 

venting

 

system.

 

England’s

 

Stove

 

Works

 

is

 

not

 

responsible

 

for

 

any

 

damage

 

incurred

 

due

 

to

 

a

 

poor

 

or

 

unsafe

 

installation.

 

Be

 

certain

 

that

 

all

 

aspects

 

of

 

the

 

venting

 

system

 

are

 

installed

 

to

 

the

 

venting

 

manufacturer’s

 

instructions,

 

particularly

 

the

 

required

 

clearances

 

to

 

combustibles.

 

Also,

 

be

 

certain

 

to

 

use

 

an

 

attic

 

radiation

 

shield

 

to

 

prevent

 

insulation

 

from

 

contacting

 

a

 

chimney

 

which

 

passes

 

through

 

an

 

attic.

 

The

 

chimney

 

system

 

is

 

the

 

“engine”

 

which

 

drives

 

a

 

wood

 

stove,

 

so

 

it

 

is

 

imperative

 

for

 

proper

 

unit

 

function

 

that

 

the

 

venting

 

system

 

be

 

installed

 

exactly

 

as

 

described

 

in

 

the

 

following

 

section.

 

If

 

questions

 

arise

 

pertaining

 

to

 

the

 

safe

 

installation

 

of

 

the

 

stove,

 

our

 

Technical

 

Support

 

line

 

(800

245

6489)

 

is

 

available.

 

Contact

 

your

 

local

 

code

 

official

 

to

 

be

 

certain

 

your

 

installation

 

meets

 

local

 

and

 

national

 

fire

 

codes,

 

and

 

if

 

you’re

 

uncertain

 

about

 

how

 

to

 

safely

 

install

 

the

 

stove,

 

we

 

strongly

 

recommend

 

contacting

 

a

 

local

 

NFI

 

certified

 

installer

 

to

 

perform

 

the

 

installation.

 

Venting

 

Guidelines:

 

ALWAYS

 

install

 

vent

 

pipe

 

in

 

strict

 

adherence

 

to

 

the

 

instructions

 

and

 

clearances

 

included

 

with

 

your

 

venting

 

system.

 

 

DO

 

NOT

 

connect

 

this

 

wood

 

stove

 

to

 

a

 

chimney

 

flue

 

which

 

also

 

serves

 

another

 

appliance.

 

 

DO

 

NOT

 

install

 

a

 

flue

 

pipe

 

damper

 

or

 

any

 

other

 

restrictive

 

device

 

in

 

the

 

exhaust

 

venting

 

system

 

of

 

this

 

unit.

 

 

USE

 

an

 

approved

 

wall

 

thimble

 

when

 

passing

 

through

 

a

 

wall

 

and

 

a

 

ceiling

 

support/fire

 

stop

 

when

 

passing

 

through

 

a

 

ceiling.

 

WOOD - 

Meets

 

the

 

2015

 

U.S.

 

Environmental

 

Protection

 

Agency’s

 

crib

 

wood

 

emission

 

limits

 

for

 

wood

 

heaters

 

sold

 

after

 

May

 

15,

 

2015

 

Summary of Contents for 13-NCMH

Page 1: ...ION MANUAL Manufactured By England s Stove Works Inc PO Box 206 Monroe VA 24574 Rev 12 2019 www heatredefined com Questions 800 245 6489 Parts 800 516 3636 Wood Stove MODELS 13 NC 50 SNC13 50 TNC13 SAVE THESE INSTRUCTIONS ...

Page 2: ... 19 Fiber Board 19 Burner Tubes 20 Creosote 21 Ash Disposal 21 Questions Hints and Tips 22 Parts and Options Parts Options List 24 Exploded View 25 Legs Pedestal Installation 25 Warranty Sample Tag 26 Warranty Details 27 Warranty Registration Form 28 Important Information EPA and Safety Info 30 IMPORTANT NOTES CLEARANCES MAY ONLY BE REDUCED BY MEANS APPROVED BY THE REGULATORY AUTHORITY HAVING JURI...

Page 3: ... accordance with the Manufactured Home and Safety Standard HUD CFR 3280 Part 24 and must comply with local building and fire codes Failure to follow these instructions could result in property damage bodily injury or even death Keep children furniture fixtures and combustibles away from any heating appliance NOTE THIS STOVE IS MOBILE HOME AND DOUBLE WIDE APPROVED WITH OUTSIDE AIR HOOK UP FOR THE P...

Page 4: ...information obtained on our web site and through our 800 number is always free of charge there will be a service charge incurred with any on site repairs or maintenance that we may arrange Wishing you years of efficient quality and comfy heating England s Stove Works Technical Support Department www HeatRedefined com 800 245 6489 This manual is available for free download on the manufacturer s web...

Page 5: ...ble liquids or other combustible materials too close to the unit 12 Contact your local fire authority for information on how to handle a chimney fire Have a clearly understood plan to handle a chimney fire In the event of a chimney fire turn air control to a closed position and CALL THE FIRE DEPARTMENT 13 DO NOT tamper with the combustion air control beyond normal adjustment 14 Once the required d...

Page 6: ...h the top of the firebricks Overloading may prevent sufficient air entering the heater to properly fuel the fire Do not tamper with the combustion air control beyond the normal adjustment capacity Operate this heater only with the door closed ALWAYS PROVIDE A SOURCE OF FRESH AIR INTO THE ROOM WHERE THE UNIT IS INSTALLED FAILURE TO DO SO MAY RESULT IN AIR STARVATION OF OTHER FUEL BURNING APPLIANCES...

Page 7: ...f eighteen inches 18 0 from a combustible wall and eighteen inches 18 0 from ceiling 3 Installation of a New Flue System Note Flue systems and flue pipe are not furnished with the unit Masonry Flue In the event that you plan to install or have a system installed there are several approaches that you can take In the middle and late seventies masonry flue systems became very popular and today this t...

Page 8: ...8 13 0 Min 13 0 Min 13 0 Min Single wall chimney connector 18 Min USA Follow all venting system manufacturer s installation requirements AND their required clearances ...

Page 9: ... 5 in Single Wall Chimney Connector 18 Min Min Alcove Width 64 0 in Min Alcove Height 84 0 in Max Alcove Depth 48 0 in CANADA Follow all venting system manufacturer s installation requirements AND their required clearances ...

Page 10: ...10 INSTALLATION APPLICATIONS Cont d Illustration 1b In Canada the installation must conform to CAN CSA B365 when passing through combustible construction ...

Page 11: ...ou are unable to install this type system your local dealer may be able to recommend a qualified contractor for this installation It is the customer s responsibility to ensure that his system is installed properly and is in good operating condition The manufacturer will not be responsible for an accident caused by a unit connected to a faulty flue system FLOOR AND WALL PROTECTION 1 Floor Protectio...

Page 12: ...rnate is 4 brick with a C factor of 1 25 over 1 8 mineral board with a k factor of 0 29 Step a Use formula above to convert specification to R value R 1 k x T 1 0 84 x 75 0 893 Step b Calculate R of proposed system 4 brick of C 1 25 therefore R brick 1 C 1 1 25 0 80 1 8 mineral board of k 0 29 therefore Rmin bd 1 0 29 x 0 125 0 431 Total R Rbrick Rmineral board 0 8 0 431 1 231 Step c Compare propo...

Page 13: ...ear Heat Shield and fasten with the screws provided See Illustration 1 for clearances with and without side heat shields Rear Heat Shield Side Heat Shield Side Heat Shield Illustration 3 Side Heat Shield and Blower Installation Install AC 16 Optional Blower on these 4 mounting holes See Optional Blower Instructions on page 6 for instructions Illustration 4 BRICK LAYOUT 1 9 x 4 x 1 25 brick Qty 11 ...

Page 14: ...t has the factory packaging remove the body of the stove from the shroud that it is attached to referring to Illustration 7 later in this manual Those instructions detail how to exchange legs and pedestal but removal of the shroud is accomplished in the same manner 2 Select the proper location for the stove These appliances must not be installed any closer than the minimum clearance to combustible...

Page 15: ...nstall in accordance with 24 CFR Part 3280 HUD Outside Air Connection When installing this model in a mobile home or double wide it is necessary to supply the combustion air into the unit from outside the dwelling NOTE THIS STOVE IS MOBILE HOME AND DOUBLE WIDE APPROVED WITH OUTSIDE AIR HOOK UP FOR THE PEDESTAL MODEL ONLY NOT FOR LEG MODELS This can be done by running a thin gauge three inch 3 pipe...

Page 16: ...O CHIMNEY AND CHIMNEY CONNECTOR MANUFACTURER S INSTRUCTIONS WARNING INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER CONTACT YOUR LOCAL BUILDING AUTHORITY FOR APPROVED METHODS OF INSTALLATION 1 This appliance requires a masonry or pre manufactured chimney listed to UL103HT ULC S629 if Canada sized correctly 2 If a masonry chimney is used it is advisable to have your chimney inspected ...

Page 17: ...t effectively when air is allowed to circulate to all areas of the firebox A good way of achieving this is to rake a small 1 to 2 wide trough in the center of the coal bed from front to back prior to loading the fuel 7 Once fuel has been loaded close the door and fully open the air inlet control until the fire is well established approximately 20 minutes being careful not to over fire 8 Readjust t...

Page 18: ...ce deposits on the glass GASKET REPLACEMENT After extensive use the sealing material which provides glass and door seal may need to be replaced if it does not sustain its resilience Inspect the glass and door seal periodically to ensure proper seal If the gaskets become frayed or worn replace immediately Contact your dealer or Customer Service at 800 245 6489 for approved replacement parts The fol...

Page 19: ... SURE IT IS LYING FLAT ON TOP OF THE THREE STAINLESS STEEL TUBES AND PUSHED ALL THE WAY TO THE BACK OF THE UNIT WITH NO GAPS BETWEEN IT AND THE BACK WALL Call 800 245 6489 if questions MAINTENACE This unit is equipped with a ceramic Fiber Board ceiling baffle After extensive use the board should be removed and cleaned The following steps should be followed for cleaning or replacement 1 Ensure the ...

Page 20: ...20 Placement of Stainless Steel Burner Tubes for all 13 NCMH 50 SNC13MH and 50 TNC13MH stove models ...

Page 21: ...A small hot fire is preferable to a large smoldering one that can deposit creosote within the system 5 Establish a routine for fuel wood burner and firing technique Check daily for creosote build up until experience shows you how often you need to clean to be safe Keep in mind that the hotter the fire the less creosote is deposited and weekly cleanings may be necessary in milder weather although m...

Page 22: ...on of smoke is a good indication that the draft in the chimney has begun and good combustion is now possible Larger pieces of seasoned dry firewood can now be added when there is sufficient space in the firebox Adjust the air control setting to your desired setting NOTE The lower the air control setting the longer the burn time of the firewood 2 What type of wood is best to use as firewood Dry sea...

Page 23: ...s and door seals can all keep heat in but may also make a home too airtight If you are in doubt as to whether or not there is sufficient air in your home for your stove refrain from using those appliances known to consume air when possible or open a door or a window to allow some air to enter the home C Environmental Conditions High trees a low lying house location such as in a valley tall buildin...

Page 24: ...RAMIC FIBER BOARD AC SH BRASS DOOR SPRING HANDLE AC SHN NICKEL DOOR SPRING HANDLE AC SH4 BRASS AIR CONTROL SPRING HANDLE AC SH4N NICKEL AIR CONTROL SPRING HANDLE AC 03 BRASS ASH PAN KNOB AC 03BN NICKEL ASH PAN KNOB AC MBSP HI TEMPERATURE BLACK PAINT OPTIONS AC 16 ROOM AIR BLOWER AC NCSHSB SIDE HEAT SHIELD SYSTEM BLACK AC 108 BRASS ACCENT TRIM RING FOR DOOR C P AND L MODELS ONLY AC 108BN NICKEL ACC...

Page 25: ...o a slot and match the hole on the leg with the hole in the slot Attach the legs one at a time using the supplied bolts and nuts Tighten securely To install pedestal 1 Place spacers provided between the slots on the unit and the pedestal base one spacer will fit on each side of the pedestal Match the four holes in the pedestal 2 on each side with the holes in the spacers and slots on the unit 2 Us...

Page 26: ...anufacture Date and Serial Number in the blank spaces on this sample tag for future reference This sample tag also shows the safety info such as UL testing standard etc for your local officials or anyone else who may need reference information ...

Page 27: ...urs because of an accident improper handling improper installation improper operation abuse or unauthorized repair made or attempted to be made The manufacturer is not liable for indirect incidental or consequential damages in connection with the product including any cost or expense providing substitute equipment or service during periods of malfunction or nonuse All liability for any consequenti...

Page 28: ...Purchase Date _________________ Purchase Price ____________________ Serial Number _____________________ Mfg Date ______________________ How did you first hear about our product please check one ___ Word of Mouth ___ Burn Trailer Demonstration ___ Internet Other ____________________________________________________ Where did you receive information about our product please check one ___ Rec d info v...

Page 29: ...29 ...

Page 30: ...lt in poor stove performance property damage bodily injury or death Avoid make shift compromises when installing the venting system England s Stove Works is not responsible for any damage incurred due to a poor or unsafe installation Be certain that all aspects of the venting system are installed to the venting manufacturer s instructions particularly the required clearances to combustibles Also b...

Page 31: ...or Building a Fire will ensure a proper fire as well as helping minimize visible emissions More Fuel loading and re loading Practical Tips for Building a Fire See your owner s manual for information on loading and re loading your fuel as well as for fire starting procedures i e Building a Fire Top Down Fires The US EPA recognizes the effectiveness of the top down approach for starting fires A good...

Page 32: ...about 12 to 15 percent Most air dried material is usually closer to 20 percent moisture content when used To test your firewood simply push the pins into the wood and wait for a reading Remember don t just stick the meter into the ends of your firewood To get the most accurate reading split the wood and test the center The center of the log will contain the most moisture How Far Should I Drive Non...

Page 33: ...w these guidelines for safe operation Keep all flammable household items drapes furniture newspapers and books far away from the appliance Start fires only with newspaper dry kindling and all natural or organic fire starters Never start a fire with gasoline kerosene or charcoal starter Do not burn wet or green unseasoned logs Do not use logs made from wax and sawdust in your wood stove they are ma...

Page 34: ...ce alarms CAUTION This unit is meant to operate only with door closed Smoke spillage and an inefficient lazy burn will result from attempting to operate the stove with the door open Additionally using prohibited fuels can create an unsafe situation and can also generate excess carbon monoxide Carbon monoxide is an odorless colorless gas which can be deadly The use of a carbon monoxide detector is ...

Reviews: