background image

P

 

   

GH Manual

 

IOM-62 

4 of 9 

Nov 17 R1 

 
WARRANTY 

LIMITED WARRANTY

 TRI-MED will furnish without charge, F.O.B. factory, freight collect, replacement 

parts for, or repairs to products covered herein which prove defective in material or workmanship 
under normal and proper use for a period of twelve (12) months from the date of shipment, provided 
the customer gives TRI-MED written notice of such defects within such time periods and provided that 
inspection by TRI-MED establishes the validity of the claim and all pertinent invoices have been  paid in 
full.  The repairs or replacements will be made only when the complete product(s) or part(s) claimed to 
be defective are returned to TRI-MED or a depot designated by TRI-MED, transportation charges 
prepaid.  Repairs or replacements as provided for by this paragraph shall constitute fulfillment of all 
TRI-MED's obligations with respect to this warranty.  Corona plates and filters are considered 
consumable items and are to be replaced by the owner/operator as per the maintenance schedule.  
Corona plates broken after original shipment will not be considered a manufacturing defect and 
replacement will be the responsibility of the owner/operator.  This warranty does not apply to any 
products or parts thereof that have been subject to accident, misuse or unauthorized alterations, or 
where TRI-MED's installation and service requirements have not been met.  
 
The foregoing warranty is in lieu of all other warranties, express or implied.  TRI-MED specifically 
disclaims any implied warranty of merchantability and/or fitness for purpose.  Under no circumstances 
shall TRI-MED be liable to, nor be required to indemnify, Buyer or any third parties for any claims, 
losses, labour, expenses or damages (including special, indirect, incidental, or consequential damages) 
of any kind, resulting from the performance (or lack thereof) of this Agreement or the use of, or 
inability to use the goods sold hereunder, including, but not limited to, damages for delay, temporary 
heating/cooling costs, loss of goodwill, loss of profits or loss of use.  Furthermore, the parties agree 
that the Buyer's sole remedy under this Agreement shall be limited to the limited warranty set forth in 
the preceding paragraph relating to the repair or replacement of any defective goods.  Under no 
circumstances shall any claim or award against TRI-MED exceed the original contract price whether 
awarded through arbitration, litigation or otherwise.  
 
TRI-MED Warranty is void if: 
 
1.

 

The unit is not installed in accordance with this manual.  

2.

 

The start-up and operation of the unit is not performed in accordance with this manual.  

3.

 

The unit is operated in an atmosphere containing corrosive substances.  

4.

 

The unit is allowed to operate during building construction. 

 

 

 

Summary of Contents for TriMed GH Series

Page 1: ...STINGS CRES SE CALGARY ALBERTA T2G 4C8 Ph 403 287 2590 Fx 888 364 2727 32050 W 83 rd STREET DESOTO KANSAS 66018 Ph 913 583 3181 Fx 913 583 1406 1175 TWINNEY DRIVE NEWMARKET ONTARIO L3Y 5V7 Ph 905 898 1114 Fx 905 898 7244 SALES OFFICES ACROSS CANADA AND USA Retain instructions with unit and maintain in a legible condition Please give model number and serial number when contacting factory for inform...

Page 2: ... 3 Warranty 4 Parts 5 Receiving 5 Temporary Storage 5 Installation 5 Codes 6 In Canada 6 In Usa 6 Assembly Drawing 6 Electrical Connections 7 Before Starting 7 Maintenance 7 Maintenance Schedule 7 Electrical 8 Corona Plates 8 Corona Plate Inspection 8 Troubleshooting Chart 9 Airtex Manufacturing LLLP All rights reserved ...

Page 3: ...nt The submittal record is considered to be part of the Installation Operation and Maintenance Manual SAFETY PRECAUTIONS Read understand and follow the complete manual before beginning the installation including all safety precautions and warnings Warning This unit contains high voltage circuits Electrical shock or death could occur if instructions are not followed This equipment contains moving p...

Page 4: ...o accident misuse or unauthorized alterations or where TRI MED s installation and service requirements have not been met The foregoing warranty is in lieu of all other warranties express or implied TRI MED specifically disclaims any implied warranty of merchantability and or fitness for purpose Under no circumstances shall TRI MED be liable to nor be required to indemnify Buyer or any third partie...

Page 5: ... is found refer to the instructions on the back of packing slip On receipt of the unit check the electrical characteristics see rating plate to make sure that the electrical supply matches All parts for field installation are listed on the shipping order form TEMPORARY STORAGE If a unit is to be stored prior to installation the following precautions are required Store in a well drained area that w...

Page 6: ...hall be in accordance with all other National Provincial and Local Codes and in accordance with the local authorities having jurisdiction In USA 1 The installation of this unit shall be in accordance with the latest edition of the National Electrical Code ANSI NFPA 70 State and Local Codes and in accordance with the local authorities having jurisdiction 2 This unit shall be electrically grounded i...

Page 7: ...g DO NOT bypass any interlock or safety switches under any circumstances m c The effectiveness of the GH generator head is a function of its ability to convert oxygen O2 to ozone O3 through high voltage corona plates It is essential to maintain airflow through clean corona plates Dirty filters will not only reduce the oxygen across the corona plates but also can change the air balance To provide a...

Page 8: ...o sets Clean the dirty corona plates by using a dishwasher or hand wash If cleaning by hand begin cleaning the plates by spraying or dipping them in cleaning solution The cleaning solution should be a detergent product that is capable of breaking down oils and greases but leaves no residue when rinsed off If the plates are rinsed in hard water then clean compressed air should be used to dry off of...

Page 9: ...izer Output control higher Energize additional generator heads Verify air flow balance across head assembly Corona plates dirty Clean corona plates See Plate Cleaning on page 8 No voltage at plates after cleaning Inspect for plate damage and replace damaged plate Defective transformer Check primary and secondary voltages and replace if required Clean Plate Dirty Plate Broken Plate ...

Reviews: