background image

Wireless Mesh AP Installation with EMR 

Series Routers

 

A)

  Search for 

“EnMesh by EnGenus” on App Store or Google Play.

 

B)

  Download the EnMesh APP to set up the EnGenius Mesh Router.

 

C)

  Add EMD2 via 

“Wizard” or “Device Page” in EnMesh App.

 

 
 
 
 

 

Easy Management App

 

 
 
 
 
 
 

 

B) 

Plug in the EMD2 to an electrical outlet and wait the LED 

flash blue.

 

 

 

 

 

Once your computer is on,ensure that your TCP/IP is set to 

On 

or 

Enabled

. Open 

Network Connectons 

and then click Local Area Connecton.  Select 

Internet 

Protocol Version 4 (TCP/IPv4).

 

 

 

 
 

 

Pluging 

LED lighting

 

 

 

 

 

 

If your PC is already on network, ensure that you have set it to a static IP Address 
on the interface. (Example: 192.168.1.10and the Subnet Mask address as 
255.255.255.0.

 

Note: 

EMD1 will be shown 

”En SN last 6 digits” in EnMesh easy setup 

page.

 

 

 

 

 

 

 

Mounting the Access Point

 

A)

 

Attach the mounting bracket to the ceiling / wall using the provided

 

mounting kit. 

C

 

B)

 

Insert the provided short screws into the mounting holes to 

fix the bracket to the 

ceiling/wall.

 

C)

 

Check the align mark between unit and bracket in the right place. Then, the power and 
ethernet cable can smoothly pass through the groove space.

 

 

Ethernet Cable

 

D)

 

Mount the access point to the bracket by rotating the unit clockwise about

 

45 degree to secure it in place.

 

 
 

 

A

 

D

 

 
 

Power Cord

 

 
 
 

 

 

 

 

 

To attach the Access Point to a

 

ceiling using T-Rail Holder 

C

 

A)

  Attach the T-rail holder to the bottom cover of the bracket. Also mount bracket to 

the unit by rotating 45 degree to secure it in place.

 

B)

  Insert the provided screw into the T-rail holder.

 

C)

  Line up the connected T-rail holder with an approiately sized and press the unit 

onto the rail unit it snaps into space.

 

 
 
 
 
 
 
 
 
 
 

T-Rail

 

B

 

 
 

Technical Support

 

 
 
 
 
 

Africa / Middle East

 

 
 

 

Asia / Oceania

 

 

 

A)

 

bracket

安裝在牆或天花板上

 

B)

 

固定在牆上或天花板

 

 
 
 
 
 

[email protected] Toll 
Free: 888 397 2788

 

Local: (+1) 905 940 8181

 

 

[email protected] Toll 
Free: 885 735 7888

 

Local: (+1) 714 432 8668

 

 
 

 

[email protected] 
Local: (+31) 40 8200 887

 

 
 
 

[email protected]  Local: 
(+971) 4 357 5599

 

 
 
 

 

[email protected] 
Local: (+65) 6227 1088

 

 
 

 

C

F

e

de

r

a

C

o

穿

m

m

凹槽

u

n

ic

a

ti

/

o

n

調

C

o

m

m

ission Interference Statement

 

D) 

對準

後旋轉

 / 

45

度扣緊

 

This device complies with Part 15 of the FCC Rules. Operation is subject to the following

 

two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any 
interference received, including interference that may cause undesired operation.

 

This equipment has been tested and found to comply with the limits for a Class B digital device, 

pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against 
harmful  interference  in  a  residential  installation.  This  equipment  generates,  uses and can radiate radio 
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful 
interference to radio communications. However, there is no guarantee that interference will not occur in a 
particular installation. If this equipment does  cause harmful interference to radio or television reception, 
which can be determined by turning the equipment o

 and on, the user is encouraged to try to correct the 

interference by one of the following measures:

 

- Reorient or relocate the receiving antenna.

 

- Increase the separation between the equipment and receiver.

 

- Connect the equipment into an outlet on a circuit di

erent from that to which the receiver is connected.

 

- Consult the dealer or an experienced radio/TV technician for help.

 

FCC Caution:

 

Any changes or 

modifications not expressly approved by the party responsible for compli- ance could 

void the user's authority to operate this equipment.

 

This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

 

Radiation Exposure Statement:

 

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. 

This equipment should be installed and operated with minimum distance 20cm between the radiator & 
your body.

 

 

Taiwan

 

www.engeniustech.com.tw

 

 

[email protected] Toll 
Free: 0800 003 885

 

Local:(+886) 2 2652 1808

 

Maximum data rates are based on the IEEE standards. Actual ehroughput and range may vary depending on may factors including 
environment conditions, distance between devices, radio interference in the operating environment, and mix of devices in the 
network. Feature and specification subject to change without notice. This device complies with Part 15 of the FCC Rules. Operation is 
subject to the following two condition: (1) this device may not cause harmful interference, and (2) this device must accept any 
interference received, including interference that may cause undesired operation. Trademark and registered trademarks are the 
property of their respective owners. For United States of America: Copyright ©  2018 EnGenius Technologies, Inc. All rights reserved.

 

 
 
 
 
 

EMD2

 

EMD2 

AC1300 Wireless Access Point

 

B

 

A

 

Reviews: