Integrated Synchronous Servo Drives
HBI 22xx / HBI 26xx / HBI 32xx / HBI 37xx
Operating Manual Rev. 1.6
www.engelantriebe.de
page 31
6
Installation
6.1
Cable types, cable lengths, shielding
EMC note
:
In the test lab, the adherence to the limit values specified by the EMC product standard DIN
EN 61800-3 (VDE 0160-103): 2005-07, EN 61800-3:2004 has been confirmed:
Emission
1)
:
second environment / limited availability (Category C3)
Immunity:
second environment
1)
Cable-based emissions must be suppressed through appropriate filtering measures
in the energy supply (e.g. power supply unit) of the device
.
The following recommendations for installation have been created in accordance with test
lab conditions.
Warning
In a residential area this product can cause high-frequency disturbances, which may
necessitate interference suppression measures
.
For the optimal operation of the HBI series drives, ENGEL offers cable assemblies in various standard lengths
(see below). Deviating lengths on request.
Requirements on the supply / signal line:
Recommended wire cross-section for voltage supply: 1.5mm² (Observe voltage drop on the lead!)
The voltage supply should be stranded in pairs and have shielding
Minimum wire cross-section for signals: 0.14mm²
Flexibility in accordance with the specific application, max. operating temperature ≤80°C.
Connect the overall shield with the lowest possible impedance to protective earth.
Type recommendation:
ENGEL original accessories:
Item no. 9900000575 (2m)
Item no. 9900000576 (5m)
Cable
assembly
with
connection
plug,
open
on
one
end,
3x 1.5mm² (shielded) + 12x 0.14mm² (shielded), suitable for drag chains.