5.3.3. Typical Input Current
Test Conditions:
Typical Results @ 3.7 V with 2000
μ
F at connector input on V
BAT
terminated into a 50
Ω
resistive load.
GSM Operation
Input Current
Band Mode
Low
Nom/Avg High/Peak Units
1900
mA
1800
mA
900
mA
850
1 RX/1 TX, Full Power
mA
ALL
Idle
N/A
Shutdown
GPRS Operation
Input Current
Band Mode
Low
Nom/Avg High/Peak Units
4 RX/1TX, Full Power
mA
2 RX/2TX, Full Power
mA
1900
1 RX/1TX, Full Power
mA
4 RX/1TX, Full Power
mA
2 RX/2TX, Full Power
mA
1800
1 RX/1TX, Full Power
mA
4 RX/1TX, Full Power
mA
2 RX/2TX, Full Power
mA
900
1 RX/1TX, Full Power
mA
4 RX/1TX, Full Power
mA
2 RX/2TX, Full Power
mA
850
1 RX/1TX, Full Power
mA
ALL
Idle
N/A
Shutdown
5.3.4. GSM Transmit Power
Enfora Enabler III-G module
Power Class
Transmit Power
1900 MHz
1800 MHz
GSM Power Class 1
1-W conducted power maximum (30
dBm +/- 2 dB), measured at the
antenna port
850 MHz
900 MHz
GSM Power Class 4
2-W conducted power
maximum (33 dBm +/- 2 dB),
measured at the antenna port
GSM0308PB001
19
Version DRAFT – 2/9/2007