2.1 Solution 3.4 Specifications
Fuel Type
Cordwood
Test Standards (safety)
ULC S627 and UL 1482
Test Standard (emissions)
EPA Method 28 (40 CFR Part 60)
Heating capacity range*
1,000 to 2,700 sq. ft. (93 to 251 m
2
)
Maximum heat output**
(EPA test fuel)
60,175 BTU/h (17.64 kW/h)
Maximum heat output**
(natural hardwood fuel)
100,000 BTU/h (29.31 kW/h)
Optimum efficiency
78 %
Particulate Emissions
3.9 g/h
Test Standard (efficiency)
CSA B415.1
Burn Time*
9 to 10 hours
Shipping Weight
547 lb (248 kg)
Firebox Volume
3.4 cu.ft. (0.104 m
3
)
Maximum Log Length
22" east-west***
Flue Outlet Diameter:
6" (150 mm) diameter (vertical)
Baffle Material
C-Cast
Mobile home approved
No
* Burn time and heating capacity may vary subject to location in home, chimney draft, chimney
diameter, locality, heat loss factors, climate, fuels and other variables.
** The EPA test fuel is dimensional Douglas fir pieces stapled together into cribs with air spaces
between. We also test using the same procedure except using split hardwood firewood to reflect
real-world heat output. This stove is not intended to operate at its peak heat output continuously.
*** East-west: through the door you see the sides of the logs; north-south: through the door you
see the ends of the logs.