During the Inclusion/ Exclusion process, the 

manual 

ON/OFF 

button

 is used for including/ excluding the device.

It is best to perform an Exclusion of the device prior to performing an Inclusion. 

Step 1. 

From the Control Panel, go the the device Exclusion page.

Step 3. 

Follow the On-Screen instructions in the Control Panel on adding or 

removing rooms, 

scenes, other devices, and other functions and features.

OPERATING THE 

ZW

N-323

M-Plus

You're  now  ready  for  basic  operation  of  the 

ZW

N-323

M-Plus

.  The

 

manual button

  turns  the 

controlled receptacle (

right side

)

 

ON/OFF when  the 

button

 is 

pressed 

once

.  It  can  also be 

operated from  your desktop 

on the control panel provided on the Hub 

manufacturer's website

 

or a smart device such as the iPhone, iPad or any Android device

 once the appropriate App is installed on the 

device

.

 

-

Push button

 will respond to ALL-ON and the ALL-OFF command (default).

-

Push button

 will not respond to ALL-ON or ALL-OFF commands.

-

Push button 

will respond to the ALL-OFF command but will not respond to the ALL-ON command.

-

Push button

 will respond to the ALL-ON command but will not respond to the ALL-OFF command.  

Configuration details

Parameter 1 (configure LED light state ), default value is 0. Valid 

values are 0 and 1 with 1 byte.

Parameter 2 (configure  button toggle), default value is 0. Valid 

values are 0 and 1 with 1 byte. 

PROGRAMMING

ZW

N-323

M-Plus

DEVICE INCLUSION/ EXCLUSION

The process of "Inclusion/ Exclusion" is to Add or Remove the device from the Hub. All Z-Wave devices must be "Included" on the Controller (Hub) before it can 

be controlled from a smart device. The Hub should be brought physically closer to the device just for the "Inclusion" process (

recommended within 10ft

). When 

finished, the Hub and device can be moved back to final installation location. Download the App or log onto the website associated with the Hub you are using 

and follow thei

r

 Inclusion/ Exclusion instructions as each Hub's programming and features are different.

ADVANCED PROGRAMMING

WARNING:

 

Advanced programming is recommended ONLY for experienced programmers. 

The 

ZWN-323M-Plus

 has customizable f

eatures/functions 

that require 

writing codes. Changes to code may cause device to function improperly or to not function at all.

The following parameters require that you have an advanced controller. Basic remotes do not have this capability.

LED Light and Buttons Configuration 

By default, one press 

of the 

manual

 button 

will turn 

the Load 

on

 

and 

the 

LED

 

indicator

 will turn off.

 U

se 

"

Command_Class_Configuration

"

 to configure 

the 

LED 

indicator

 

to operate in reverse when the button is pressed

.

o

Select "Exclude Device".

o

When prompted, press the 

manual ON/OFF

 Button on the 

module

.

Step 2. 

Go to the "Add Device" page.

o

Select "Include Device".

o

When prompted, press the 

manual ON/OFF

 Button on the 

module

The primary controller should indicate that the action was successful. If the controller indicates the action was unsuccessful, 

please repeat from Step 1.

 

Once the 

module 

is part of the network, the same basic procedure is used to add the switch to groups 

& scenes or change advanced functions. Refer to the primary controller’s instructions for details. 

Parameter 

Size

Description

Valid Value

8

1 Byte

Default=0

9

1 Byte

Default=0 

10

1 Byte

Default=0 

11

1 Byte

1: Send

12

1 Byte

Default=10

0: Not report

(METER_REPORT) only

Default 

1-

1-255: 1-255 Min

255: 1-255 Min

0: not send

0: not send

Default=1

2: Send

(SENSOR_MULTI

LEVEL_REPORT) only

3: Send both

(METER_

(SENSOR_
REPORT)

NO.

Instant Energy Autosend 

Interval

(send METER_REPORT)

Instant Energy Autosend 

Interval

(send  SENSOR_

MULTILEVEL_REPORT)

Accumulated Energy 

Autosend Interval report

 

(send METER_REPORT)

REPORT) and
MULTILEVEL_

Value

0-255: 0.0-25.5W

1-255: 1-255 Min

0: not send

1-255: 1-255 Min

0: not send

Minimum change in

 

 wattage report

Enable automatic 

notifications to 

associated device 

whenever the

re

is a 

wattage change

1

1 Byte

Default=0

synchronization of load

 

power and LED indicator

0: Power on, LED off

1: Power on, LED on

All-ON and All-OFF

Depending upon your primary controller, the 

ZWN-323M-Plus

 can be set to respond to ALL-ON and ALL-OFF commands in four 

different ways. Some controllers may not be able to change the response from its default setting. Please refer to your 

controller’s instructions or technical support for information on whether or not it supports the configuration function and if so, 

how to change this setting. 

The four possible responses for 

the manual ON/OFF button

 are: