During the Inclusion/ Exclusion process, the
manual
ON/OFF
button
is used for including/ excluding the device.
•
It is best to perform an Exclusion of the device prior to performing an Inclusion.
Step 1.
From the Control Panel, go the the device Exclusion page.
Step 3.
Follow the On-Screen instructions in the Control Panel on adding or
removing rooms,
scenes, other devices, and other functions and features.
OPERATING THE
ZW
N-323
M-Plus
You're now ready for basic operation of the
ZW
N-323
M-Plus
. The
manual button
turns the
controlled receptacle (
right side
)
ON/OFF when the
button
is
pressed
once
. It can also be
operated from your desktop
on the control panel provided on the Hub
manufacturer's website
or a smart device such as the iPhone, iPad or any Android device
once the appropriate App is installed on the
device
.
-
Push button
will respond to ALL-ON and the ALL-OFF command (default).
-
Push button
will not respond to ALL-ON or ALL-OFF commands.
-
Push button
will respond to the ALL-OFF command but will not respond to the ALL-ON command.
-
Push button
will respond to the ALL-ON command but will not respond to the ALL-OFF command.
Configuration details
•
•
Parameter 1 (configure LED light state ), default value is 0. Valid
values are 0 and 1 with 1 byte.
Parameter 2 (configure button toggle), default value is 0. Valid
values are 0 and 1 with 1 byte.
PROGRAMMING
ZW
N-323
M-Plus
DEVICE INCLUSION/ EXCLUSION
The process of "Inclusion/ Exclusion" is to Add or Remove the device from the Hub. All Z-Wave devices must be "Included" on the Controller (Hub) before it can
be controlled from a smart device. The Hub should be brought physically closer to the device just for the "Inclusion" process (
recommended within 10ft
). When
finished, the Hub and device can be moved back to final installation location. Download the App or log onto the website associated with the Hub you are using
and follow thei
r
Inclusion/ Exclusion instructions as each Hub's programming and features are different.
ADVANCED PROGRAMMING
WARNING:
Advanced programming is recommended ONLY for experienced programmers.
The
ZWN-323M-Plus
has customizable f
eatures/functions
that require
writing codes. Changes to code may cause device to function improperly or to not function at all.
The following parameters require that you have an advanced controller. Basic remotes do not have this capability.
LED Light and Buttons Configuration
By default, one press
of the
manual
button
will turn
the Load
on
and
the
LED
indicator
will turn off.
U
se
"
Command_Class_Configuration
"
to configure
the
LED
indicator
to operate in reverse when the button is pressed
.
o
Select "Exclude Device".
o
When prompted, press the
manual ON/OFF
Button on the
module
.
Step 2.
Go to the "Add Device" page.
o
Select "Include Device".
o
When prompted, press the
manual ON/OFF
Button on the
module
.
The primary controller should indicate that the action was successful. If the controller indicates the action was unsuccessful,
please repeat from Step 1.
Once the
module
is part of the network, the same basic procedure is used to add the switch to groups
& scenes or change advanced functions. Refer to the primary controller’s instructions for details.
Parameter
Size
Description
Valid Value
8
1 Byte
Default=0
9
1 Byte
Default=0
10
1 Byte
Default=0
11
1 Byte
1: Send
12
1 Byte
Default=10
0: Not report
(METER_REPORT) only
Default
1-
1-255: 1-255 Min
255: 1-255 Min
0: not send
0: not send
Default=1
2: Send
(SENSOR_MULTI
LEVEL_REPORT) only
3: Send both
(METER_
(SENSOR_
REPORT)
NO.
Instant Energy Autosend
Interval
(send METER_REPORT)
Instant Energy Autosend
Interval
(send SENSOR_
MULTILEVEL_REPORT)
Accumulated Energy
Autosend Interval report
(send METER_REPORT)
REPORT) and
MULTILEVEL_
Value
0-255: 0.0-25.5W
1-255: 1-255 Min
0: not send
1-255: 1-255 Min
0: not send
Minimum change in
wattage report
Enable automatic
notifications to
associated device
whenever the
re
is a
wattage change
1
1 Byte
Default=0
synchronization of load
power and LED indicator
0: Power on, LED off
1: Power on, LED on
All-ON and All-OFF
Depending upon your primary controller, the
ZWN-323M-Plus
can be set to respond to ALL-ON and ALL-OFF commands in four
different ways. Some controllers may not be able to change the response from its default setting. Please refer to your
controller’s instructions or technical support for information on whether or not it supports the configuration function and if so,
how to change this setting.
The four possible responses for
the manual ON/OFF button
are: