4
MODEL: EWC12-21525
USER’S MANUAL
TECHNICAL SPECIFICATIONS
Model Number
EWC12-21525
Type
Smart
Input Voltage
100-120Vac
Input Frequency
50/60Hz
Output
2/15/25A @ 12V
Start Voltage
2V
Charge Voltage
GEL-14.1V
AGM&WET-14.4V
Calcium-14.7V
Equalizing Voltage
GEL-14.3V
AGM&WET-14.6V
Calcium-15.5V
Float Voltage
13.2V
Rejuvenation
16.0V / 0.5-1.0A
Power Supply Output
13.8V
Temp. Compensation
-25mV/°C
Size (L*W*H) in mm
268*153*73
Weight
2.1Kg
Approvals
CE/UL/cUL/Fcc/AS/NZS/CEC
CHARGING INSTRUCTIONS
STEP 1 – PRE-CHARGE CHECK AND ELECTROLYTE LEVEL CHECK
• Check the battery electrolyte level (not required on sealed and maintenance-free batteries).
If necessary, remove the vent caps and add distilled water so the levels are halfway between the upper and lower fill lines.
STEP 2 - CONNECTING THE BATTERY CHARGER TO YOUR BATTERY
• If the battery is o
ut of the vehicle
:
- Connect the Red (+) battery charger lead to the positive (+) battery terminal.
- Connect the Black (-) battery charger lead to the negative (-) battery terminal.
• If Battery is still
in the vehicle
, determine if the vehicle is positively or negatively earthed.
- If negatively earthed (most common) – FIRST Connect the Red (+) battery charger lead to the positive (+) Battery
post and then connect the Black (-) battery charger lead to the vehicle’s chassis and away from the fuel line.
- If Positively Earthed – FIRST Connect the Black (-) battery charger lead to the Negative (-) battery post and then connect
the Red (+) battery charger lead to the Vehicle’s chassis and far away from the fuel line.
STEP 3 - CONNECT THE BATTERY CHARGER TO MAINS POWER
• Connect the battery charger to the mains power socket.
• The charger will automatically start when AC power is connected and switched on. (Note: If the Fault Indicator LED illuminates
red, please check your connections as it’s likely that the positive and negative leads are reversed. Refer to Trouble Shooting
Page for further information).