MOUNTING ON THE BOILER
Fit the enclosed flange and gasket to
the boiler.If new fixing holes must be
drilled, use the fixing flange as a pat-
tern. Use fixing screws M8-M10.
Push the burner into the flange and fix
it by means of the screws in the flange.
Ensure that the burner is fitted absolu-
tely straight.
The gas armature is from the factory
mounted in a horizontal position. The
connection of the incoming gas line is
made from the right side. Should it for
some reason be necessary to make the
gas connection in any other direction
the armature can be turned 180° to the
left and upwards. It is also possible to
connect the gas to the multi-bloc straight
backwards. The armature can also be
extended so that it comes outside the
boiler if there is not enough room.
Ensure that the distance between the
inner asembly and the gas armature is
not too long. If the distance is too long
there will not be time for the burner to
light.
INSTALLATION EXAMPLE
Connect the gas to the burner by
means of the ball valve. To facilitate
service a union nut is used between the
gas supply system and the ball valve.
Ensure that the union nut, ball valve
and tubing make it easy to remove the
burner for inspection and service.
172 205 81 97-01
Summary of Contents for Bentone STG 146