![Enertech Bentone B 30A CN Installation And Maintenance Instruction Download Page 4](http://html1.mh-extra.com/html/enertech/bentone-b-30a-cn/bentone-b-30a-cn_installation-and-maintenance-instruction_2411616004.webp)
Burner tube
Oil capacity
Output
Recommended nozzle
Recommended
kg/h
kW
Mcal/h
Angle
Danfoss
Monarch
Pump pressure
L
6,0-17,0
71-202
61-173
45° - 60°
S, B,
R, PLP
10-15 bar
The net calorific value of 11,86 kWh/kg for light oil has been used.
TECHNICAL DATA
Type designation B 30A
DIMENSIONS
OUTPUT RANGE AND NOZZLES RECOMMENDED
RECOMMENDED NOZZLE
Because of different boiler types
existing on the market, with varying
combustion chamber designs, it is not
possible to state a definite spray angle
or spray pattern.
Note that the spray angle and the spray
pattern change with the pump pressure.
175
382
ø
1
0
8
ø
1
0
8
372
B
2
2
0
2
8
1
3
0
3
ø108
35
160-190
Burner tube
Length of burner tube
Measure B
L
150
115
L
Standard
222
187
L
350
315
171 235 02 01-01
ELECTRODE ADJUSTMENT
7,0-9,0
2,5-3,5
1,0-2,0