background image

About OutBack Power Technologies 

Outßack Power Technologies is a leader in advanced energy conversion technology. 

Outßack products include true sine wave inverter/chargers, maximum power point tracking 

charge controllers, and system communication components, as weil as circuit breakers, 

batteries, accessories, and assembled systems. 

Disclaimer 

UNLESS SPECIFICALL Y AGREED TO IN WRITING, OUTBACK POWER TECHNOLOGIES: 
(a) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY

TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER

DOCUMENTATION.

(b) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE, WH ETHER DIRECT,

INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF

SUCH IN FORMATION. THE USE OF ANY SUCH IN FORMATION WILL BE ENTIREL Y AT THE

USER'S RISK.

Notice of Copyright 

GS-IOB-230VAC Installation lnstructions© February 2014 by Outßack Power Technologies. 

All Rights Reserved. 

Trademarks 

Outßack Power, the Outßack Power logo, FLEXpower ONE, Grid/Hybrid, and FLEXgrid are 

trademarks owned and used by Outßack Power Technologies, lnc. These trademarks may 

be registered in the United States and other countries. 

Date and Revision 

February 2014, Revision A 

Part Number 

900-0146-01-00 REV A

Worldwide Co

r

porate Offices

 

Alpha 

and Outback Energy

 

GmbH 

reserves the right to make changes to the products and information contained in this document without notice.

 

Copyright © 20

20

 Alpha 

and Outback Energy GmbH

. All 

Rights reserved. 

Headquarter Germany

Hansastrasse 8

D-91126 Schwabach

Tel: +49 9122 79889 0

Fax: +49 9122 79889 21

Mail: [email protected]

France and Benelux 

fbnl

@alpha-outback-energy.com

Spain 

[email protected]

For 

more

 information please visit 

www.alpha-outback-energy.com

Russia

russia

@alpha-outback-energy.com

Africa

[email protected]

Eastern Europe

[email protected]

Middle East

[email protected]

Summary of Contents for OutBack POWER ALPHA OUTBACK ENERGY GS-IOB-230VAC

Page 1: ...cular installation These instructions are for use byqualifiedpersonnel who meet all local and governmentalcoderequirements for licensing and training for theinstallationof electrical powersystems withAC and DC voltage up to 600 volts Requirements Outßack Power s GS IOB 230VAC is intended as a component for Outßack listed UL508A or UL1741 lndustrial Control Panels specifically the GSLC variants lt ...

Page 2: ...IOB 230VAC Installation lnstructions Tools Required Philips Screwdriver Fiat Screwdriver Socket Set Digital multimeter DMM or ohmmeter Components IMI Figure 1 GS 1OB 230VAC Components 2 900 0146 01 00 REVA ...

Page 3: ...ulators Fit one insulator onto each end of the bus bar 2 Insert one self tapping 10 32 x screw through the hole on each insulator Seat these screws in the GSLC chassis and screw them in These screws require a large amount of torque to start 3 Apply the correct label from the label set to the chassis near each bus bar for identification purposes Figure 2 shows the standard locations for these bus b...

Page 4: ...from the GSLC see Figure 3 2 Remove the interior cover sometimes called the dead front of the GSLC Remove the six screws installed across the top and bottom of the cover see Figure 3 and take the interior cover off 1 3 Remove the main circuit breaker bracket Remove the four screws at the top and bottom of the bracket see Figure 3 and take it off 1 4 Remove the pre installed screws in the circuit b...

Page 5: ...rcuit breaker poles Face the brackets inward as shown in Figure 4 Align the inner holes on the brackets with those on the circuit breakers 3 While placing the red brackets insert the red bypass plate between them The tabs on the plate should fit into the slots on the brackets NOTE The plate must be oriented so the hole is on the right Both circuit breakers covered by the plate must be in the OFF p...

Page 6: ...rding to their intended electrical connection lt also comes with an unlabeled green wire and two unlabeled short brown wires lf the preceding steps are followed as weil as the drawing in Figure 5 these wires will have sufficient length to make the intended connections lt is recommended that the wires be connected to the circuit breakers prior to re installing the main circuit breaker bracket To in...

Page 7: ... ...

Page 8: ...e interior cover must be re installed using the six screws and star washers previously removed The front cover can then be re installed Use the illustrations in Figure 3 on page 5 for reference There may be a label on the inside of the front cover that identifies the circuit breakers and their usage The label set included with this kit can be used to mark the circuit breakers that werejust install...

Page 9: ...tions February 2014 by Outßack Power Technologies All Rights Reserved Trademarks Outßack Power the Outßack Power logo FLEXpower ONE Grid Hybrid and FLEXgrid are trademarks owned and used by Outßack Power Technologies lnc These trademarks may be registered in the United States and other countries Date and Revision February 2014 Revision A Part Number 900 0146 01 00 REV A Worldwide Corporate Offices...

Reviews: