The two electronic devices will also provide indications
according to the table below.
1. Low Voltage Alarm
Description
Comment
Stop
Condition
1
LED
Slow
flashing
green
Normal operation
1
LED
Flashing
red
SOC < 40%, the battery
needs to be recharge soon
Battery on
charge
V>2.08V/c
1
LED
Flashing
green
(0.2s ON -
5s OFF)
Normal operation,
battery on discharge
1
LED
Fast
flashing
green
Normal operation,
battery on charge
2
Buzzer
Beeping
3 times
every
5 minutes
SOC < 40%, the battery
needs to be recharge soon
Battery on
charge
V>2.08V/c
2
Buzzer
Beeping 1
time every
5 seconds
SOC < 20%, the battery
needs to be recharged
immediately
Battery on
charge
V>2.08V/c
2. Wi-iQ
®
Description
Comment
Tricolour
LED
Green blinking
hardware OK
Blue rapid blinking
wireless identification
Red blinking
temperature warning > 55°C
Blue LED
Rapid blinking
wireless identification
Slow blinking
voltage balance warning
7. Disposal
NexSys
®
CORE batteries are recyclable. Scrap batteries must
be packaged and transported in accordance with prevailing
transportation rules and regulations. Scrap batteries must be
disposed of in compliance with local and national laws by a
licensed or certified lead acid battery recycler.