Model 1
Model 2
Model 4
Model 3
Model 4
Model 3
Model 2
Model 1
4
5
2
4
5
2
STOP / START
•Before opening the charger (only by qualified
electrical personnel) disconnect battery and mains.
•Déconnecter le chargeur du réseau et de la
batterie avant toute intervention sur le chargeur
(uniquement par une personne autorisée).
•Vor Abheben der Haube (nur von Elektrofach-
kräften) erst Netz und Batterie abtrennen.
•Ontkoppel altijd eerst batterijstekkers en
netstekker voor men de lader-afdekking
verwijdert (uitsluitend door bevoegd personneel).
3
2
3
2
4
1
1
Presentation & Use
INTRODUCTION
The
Premium ES
range of chargers enable batteries to be
recharged from the mains supply. They can recharge 24V,
36V, 48V, 72V or 80 V batteries (depending on the version
supplied).
The microprocessor control automatically recognises the
battery’s voltage, capacity, state of charge, etc., providing
optimum battery control from highly efficient analyses of its
condition. Several charging profiles are available for free
electrolyte vented lead/acid, batteries: ionic and pneumatic
mixing, valve-regulated AGM and gel, battery types,
depending on the user’s configuration. Moreover,
desulphation, equalizing and refreshing charges are also
integrated.
UNPACKING
The charger is supplied with the following components:
•
A power cable 3 metres long.
•
A battery cable 3 metres long.
•
The present Installation Instructions.
•
The Technical Characteristics sheet.
GENERAL CHECKS
Before putting the charger into service, we recommend that
you check:
•
That it is correctly earthed.
•
That the local power supply conforms to the charger’s
operating voltage.
•
That the battery voltage conforms to that of the charger.
•
That the charger’s output is suitable for the battery’s
capacity.
EXTERNAL COMPONENTS
The general components are shown below:
Ref. Function
1.
Power supply cable.
2.
Screws holding the cover.
3.
Wall fixing.
4.
Ventilation holes.
5.
Display and controls (refer to next figure).
6.
Battery cable.
7.
Wall mounting bracket
CONTROL PANEL
This contains the display and the control buttons. Please
refer to the sections The meaning of the lights and LCD
fault messages for details of the information shown.
No.
Function
1.
Start-Stop or Stop/Start switch.
2.
Green ‘Charging completed’ light (battery charged).
Unlit: charger stopped or battery not available.
Flashing: thermal fault.
Permanently lit: battery available.
3.
Red ‘Fault’ light.
Unlit: charger stopped or battery not in charge.
Flashing: charger fault.
Permanently lit: ‘Charging in progress’.
4.
LCD display.
5.
Button for exiting the menu, initiating equalisation
and initiating desulphation.
MECHANICAL INSTALLATION
The charger must be mounted on the wall free of vibrations
in a vertical position (except for floor standing chargers).
For wall-mounted chargers, the lower part of the charger
must be at least 0.60 m from the floor and/or the charger
below and the upper part 1.0 m from the ceiling. The
minimum distance between two chargers must be 0.50 m.
You must avoid areas where the chargers may be splashed