15
Troubleshooting
PROBLEM
POSSIBLE CAUSE
SOLUTION
Low oil flow rate
Inadequate air supply
Check air supply for leakage
Low oil level
Replenish oil in pump
Dirty air filter
Clean air filter in RFL
Reservoir bladder malfunction
Contact Enerpac service center
Moisture under pump Condensed water from exhaust air
Check air dryer in air supply system
Too much lubrication in intake air
Adjust air lubricator of RFL unit
Oil from reservoir overflow
Do not connect pump to retracted cylinder/actuator
Oil from internal leakage
Contact Enerpac service center
Pump feels cold
Temperature drop from expanding air Is normal after intensive use - and is not a problem
Pump feels hot
Oil temperature < 60 ºC / 140 ºF
Is not a problem
Oil temperature > 60 ºC / 140 ºF
Check oil level - replenish oil if level is low
Use pump intermittent to let oil cool down
Use pump with larger usable oil capacity
Please contact Enerpac if the DVD is not included,
or visit www.enerpac.com for a download of the manual.