Enerlites MPW-L Installation Instructions Download Page 2

4

5

6

TROUBLESHOOTING

© 201

9

 Enerlites Inc.

 

CA, 

U.S.A. 

WWW.ENERLITES.COM 

020719014

6

WARRANTY INFORMATION

This device is warranted to be free of material and workmanship defects for 2 years from 

the date of purchase. Original receipt or proof of purchase from an authorized retailer must 

be presented upon warranty claim. ALL claims must be verified and approved by Enerlites, 

Inc. Warranties from other Enerlites products may vary. This warranty is nontransferable 

and does not cover normal wear and tear or any malfunction, failure, or defect resulting from 

misuse, abuse, neglect, alteration, modification, or improper installation.  To the fullest 

extent permitted by the applicable state law, Enerlites shall not be liable to the purchaser or 

end user customer of Enerlites products for direct, indirect, incidental, or consequential 

damages even if Enerlites has been advised of the possibility of such damages.  Enerlites’ 

total liability under this or any other warranty, express or implied, is limited to repair, 

replacement or refund.  Repair, replacement or refund are the sole and exclusive remedies 

for breach of warranty or any other legal theory.

The Sensor Switch is programmed for Occupancy Mode only.

 

Automatic Turning On/Off the Load

Once the power is on, the load will be turned On according to the 

occupancy settings. The sensor time delay operates as programmed.

 

 When the load turns OFF due to the lack of motion detection, the

 

 load can be turned ON again by occupancy detection or switch

 

 activation.

The Sensor keeps the Load On until no motion is detected plus the 

set time delay, load(s) will be turned Off automatically. 

OPERATION

 PIR Activity LED does not flash:

NOTE: When power is initially applied to the sensor, there is a warm-up

period of up to 1 minute before the LED is active. 

WARNING: Turn off the power at the circuit breaker before

 installation. Lights do not turn on with occupancy, and the

 following condition exists:

1.. If the sensor’s Light Level has been turned to minimum (at positi

1), the lights connected to the Light Level Output might be held off

because of the level of ambient light in the controlled area. To test

whether the Light Level adjustment is the problem, cover the PIR lens

and PIR Activity LED  with your hand to see if the lights turn on. If

the lights turn on, the Light Level setting was keeping  the lights off

(see, “Sensor Adjustment” for readjustment).

2.. Make sure the wire is connected righ

1.. The sensor may be experiencing activations from outside t

controlled or from some type of interference (see “Unwanted Sensor

Activations” below).

2.. Make sure the wire is connected righ

1.. Check that the circuit breaker or any wall switch connected to t

sensor has been turned back on.

2.. Make sure that the PIR Sensitivity is set for Ma
3.. Make sure the wire is connected righ

PIR Activity LED flashes:

Lights do not turn off automatically: