IsoBoost Owners and Installation Manual
9
SETUP AND CONNECTIONS
INSTALLATION
PLACEMENT
The IsoBoost should be fixed to a structural part of the ship that can accept the weight of the unit. It should be fixed down
using the clearance holes in its feet.
The product is heavy and suitable lifting equipment must be used. Do not attempt to lift the IsoBoost manually. The IsoBoost
will reject some heat. Do not block vents.
The IsoBoost transformer is not waterproof. Do not expose to rain or water.
PREPARING FOR INSTALLATION
Remove the front panel of the IsoBoost unit. You will need a 4mm hex (Allen) key to remove the fixings.
A removable gland plate is situated on the right hand side of the unit. This plate will need to be drilled to install cable glands
(not supplied).
ELECTRICAL CONNECTIONS
The installation of the IsoBoost should be carried out by a qualified electrician. This unit case must be earthed in all modes
of operation.
AC INPUT
The unit should be wired to the shore supply receptacle with cable with a suitable rating to satisfy the relevant standards for
the vessel. If the IsoBoost is more than 3 metres or 10 ft from the inlet an inline circuit breaker may be required to meet
relevant standards:
Model
Cable current
IsoBoost 12 kVA US
50A Single phase
IsoBoost 24 kVA US
100A Single phase
IsoBoost 24 kVA EU
63A in buck mode
–
100 amp in 1:1 mode