VACUUM CHAMBERS TESTING DEVICE TKP-1 Type
Page 7
When the output DC voltage is switched on the LED
ATTENTION UWAGA!
f
f
l
l
a
a
s
s
h
h
e
e
s
s
HIGH
VOLTAGE WYSOKIE NAPIĘCIE
.
Once the test is finished and while viewing the memory records using the red or green
control light, the test result is shown. If the load current does not exceed the set detection
threshold during the test, then once the test is finished the green control light
PERMISSIBLE
DOPUSZCZALNA
is lit, and if the detection threshold is exceeded the red light
DEFECTIVE WADLIWA
is lit. For the red light to be lit the
ESC/CLR
button must be pressed.
MENU options
If the TKP-1 is not in the process of generating output voltage, pressing the
ENT/MENU
button the control unit switches to viewing mode of the MENU. Using the buttons
,
,
ENT/MENU,
ESC/CLR
and
PRINT DRUKUJ
enables you to view the memory records, print the
current record with the thermal printer, clear the memory, set the date and time as well as transfer
the memory records to FLASH (pen drive). Editable files as
ddggmmss
.txt (where
dd
– day of month,
gg
– hour,
mm
– minute,
ss
– second of the tester memory record) are saved in the catalogue
TKP
xxxxx
(where
xxxxx
is the factory number of the TKP-1 tester, from which the memory was
transferred
).
If there are two files with the same name, the old one will be overwritten by the
new file.
To leave the viewing of the menu press
ESC/CLR
.
4.
TESTER OPERATION
NOTE!
Due to the OSH regulations the tester must be first connected to the tested vacuum chamber that
is disconnected from the power supply voltage and opened. To connect use the delivered HV
cable and neutral wire.
The tester must be connected to 230V, 50 Hz mains socket with zero resetting-system. After
the tester is powered up with the power supply switch, the output voltage and the detection
threshold of load current must be set, unless you change these to values different from those
tested before. Current values are shown on the LCD display.
If you want to change the output voltage, you must press and hold the
SETTING NASTAWA
U
DC
button clicking the buttons
or
, changes will be displayed.
If you want to change the threshold of load current detection, you must press and hold the
SETTING NASTAWA I
DC
button clicking the buttons
or
, changes will be displayed.
While setting the output voltage or detection current, when you press the
or
button the
parameter being set is quickly changed.
The set values can be changed only when the tester control unit is in the MENU viewing
mode and is not in the process of voltage generation.