Energometrika EYD38 Operation Manual Download Page 6

 Installation of transducer and attentions

1. Mounting hole dimensions and sealing

2.The right and wrong sketch for installing holes

3. Attentions for installation

Installing holes' dimensions for 45

sealed slopes

Installing holes' dimensions for plain end face

Installing holes' dimensions for flange installation

Seal Surface

Seal Surface

Seal Surface

Fange
Diameter

Right

Wrong

Wrong

Wrong

1) Holes must be punched strictly in accordance with dimensions of installing holes for virgin 

installation. Installing holes must be thoroughly cleared in after-installations;

2) Our company provides special tools for drilling and clean holes;
3) Test system should be inspected before installed to confirm that the measurement accuracy of 

transducer/transmitter, the method described in the second table instructions; 

4) Disassembly and installation should be conducted in hot state (material melting state).the 

probe should be cleaned immediately when dismounting. Keep the probe clean. Be careful 
with probe;

 

6) Transducer and transmitter should be kept in dry environment when not used.

5)

 

Conduct

 

hot-line

 

calibration

 

with

 

pressure

 

gauge.

 

When

 

transducer/transmitter

 

reaches

 

full

 

thermal

 

equilibrium

 

after

 

1.5

 

hours

 

installed,

 

the

 

details

 

please

 

see

 

the

 

calibration

 

method

 

of

 

second

 

instrument.

 

The

 

EYD28

 

intelligent

 

pressure

 

gauge

 

our

 

company

 

produced

 

has

 

the

 

automatic

 

hot

 

state

 

calibration

 

procedures,

 

press

 

SET

 

button

 

and

 

CAL

 

button

 

and

 

then

 

loosen

 

CAL

 

button

 

until

 

the

 

pressure

 

display

 

zero

 

pressure

 

in

 

thermal

 

equilibrium

 

to

 

automatically

 

calibrate

 

the

 

test

 

system;

Summary of Contents for EYD38

Page 1: ...Operation Manual EYD38 High Temperature Melt Pressure Transducers Transmitters...

Page 2: ...h stable production organization reliable performance high accuracy strong output signal excellent dynamic performance high temperature resistant and zero drift small etc EYD38 transducers and transmi...

Page 3: ...angle 45 90 other angle can be customized Standard dimension 17 other dimensions can be customized Standard dimension 38 other dimensions can be customized flange installation Standard dimension 78mm...

Page 4: ...temperature sensor E J K S Pt100 etc Other optional thread Sizes 2PIN 3PIN Special Plug Circuits and the wiring diagram 1 Pressure transducer circuits and the wiring diagram pressure transducer power...

Page 5: ...ressure Transmitter Pressure Transmitter Pressure Transmitter 5PIN 5PIN 5PIN 6PIN 6PIN 1 Blue 3 Yellow A Red B Black E Blue 4 White 5 Green F Orange Indicator Calibration 1 Blue 2 Red 3 Yellow 4 White...

Page 6: ...alled to confirm that the measurement accuracy of transducer transmitter the method described in the second table instructions 4 Disassembly and installation should be conducted in hot state material...

Page 7: ...r sizes Code Code Code Size Size Size Pressure range 0 50MPa Thread size 1 2 20UNF Rigid stem length 150mm Flexible stemlength 370mm Pressure output singal 0 10V Double function K type thermocoupletem...

Page 8: ...The conversion table of pressure units zakaz energometrika ru www energometrika ru 7 495 276 0510...

Reviews: