background image

THIS PRODUCT MEETS ALL CERTIFICATION REQUIREMENTS FROM:

263521

Summary of Contents for eZV2000S

Page 1: ...eZV2000S USER GUIDE...

Page 2: ...to www P65Warnings ca gov 2018 Energizer Energizer and certain graphic designs are trademarks of Energizer Brands LLC and related subsidiaries and are used under license by Midland Power Inc All othe...

Page 3: ...Thanks for choosing the eZV Series You re excited to power up so we ll keep this brief Let s get started...

Page 4: ...THIS PRODUCT MEETS ALL CERTIFICATION REQUIREMENTS FROM 263521...

Page 5: ...product that should be followed during installation and maintenance of the generator This user guide covers the safety operation and maintenance procedures for the eZV2000S All information in this pub...

Page 6: ...arranty support in the future Product registration is required for all product support and warranty coverage Warranty support operation assistance and product support is provided by Midland Power Inc...

Page 7: ...g Your Generator 14 5 Generator Use 16 5 1 Output Overload and Oil Alert Indicator 16 5 2 DC Applications 17 5 3 AC Applications 18 6 Stopping the Engine 19 7 Maintenance 19 7 1 Maintenance Schedule 2...

Page 8: ...maintain the equipment Operate the generator according to instructions for safe and dependable service Before operating the generator read the user guide carefully Otherwise it may result in personal...

Page 9: ...ark plug while the engine is operating or shortly after the engine has been shut down 1 2 AC SAFETY Warning Before connecting the generator to an electrical device or power cord Make sure that everyth...

Page 10: ...ure to do so can cause severe personal injury or death Allow the generator set to cool down before performing any maintenance Always wear safety glasses when cleaning the generator set with air Do not...

Page 11: ...erator inspect the generator as well as extension cords and power supply cords connected to it for damage resulting from vibration Have damaged items repaired or replaced as necessary Do not use plugs...

Page 12: ...of your generator Going over the terminology below will make sure we re on the same page 2 1 COMPONENT IDENTIFICATION Fuel Cap Vent Lever Fuel Cap Control Panel Fuel Valve Spark Plug Access Panel Engi...

Page 13: ...6 2 2 CONTROL PANEL Reset Ground AC Outlets AC Breaker Power Choke Fuel Shutoff DC Outlet USB Low Oil Indicator Overload Indicator Output Indicator DC Breaker EcoMode Recoil Starter...

Page 14: ...dicator light turns on This will recover generator output without shutting down the engine If the generator is running normally the RESET button will have no effect NOTE The RESET button is available...

Page 15: ...d push the button back to the ON position Low Oil Indicator Light The oil alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase Before the oil leve...

Page 16: ...e screws and use the tab to loosen the top of the panel then work your way around the panel This may require some force 2 Unscrew the air filter cover and remove the filter 3 Clean the air filter with...

Page 17: ...dditional oil up to the maximum mark 6 Reinsert the oil cap and tighten securely Replace the engine access panel and screws NOTE SAE 10W 30 or SAE synthetic 5W 30 is recommended for general use Use of...

Page 18: ...e and store the engine oil with care avoid getting dirt or dust into the engine oil If the oil falls below a safe level the low oil alert system will automatically shut off the engine The low oil ligh...

Page 19: ...hanol content greater than 10 can damage the engine and the fuel system and will void the manufacturer s warranty Only use unleaded gasoline 85 Octane or higher Never use stale or contaminated gasolin...

Page 20: ...s These openings can pull in generator exhaust Even when you use a generator correctly CO may leak into the home ALWAYS use a CO alarm in your home If you start to feel sick dizzy or weak after the ge...

Page 21: ...engine is cold pull the choke lever fully out 5 Pull the starter slowly until you feel it engage then pull quickly Repeat until the generator starts 6 When the engine warms up push the choke fully in...

Page 22: ...ting the generator at altitudes above 3 280 feet 1 000m contact an authorized service center to have the carburetor modified Conversely if the carburetor has been modified for high altitude operation...

Page 23: ...lent standards The maximum length of the extension cable 60 meters 196 feet for cable of 1 5mm2 15 5 gauge 100 meters 328 feet for cable of 2 5mm2 13 25 gauge Keep away from other electric cables or w...

Page 24: ...y disconnect the vehicle battery ground cable from the negative battery terminals 2 Connect the DC outlet to the battery terminals using the included charging cable Connect red lead to positive batter...

Page 25: ...ng condition before connecting them to the generator If an electrical appliance becomes abnormal sluggish or stops suddenly shut off the generator engine immediately and disconnect the appliance Most...

Page 26: ...dition by ensuring safe economical and trouble free operation Only use genuine parts and recommended fluids to replace the worn components Improper maintenance may cause the generator to malfunction a...

Page 27: ...ry 50 Hours Every 100 Hours Every 300 Hours Generator General Inspection Engine Oil Inspect Oil Level Change Air Filter Inspection Cleaning Sediment Cup Cleaning Spark Plug Inspection Cleaning Replace...

Page 28: ...standards regarding the emission control systems Tune up specifications are provided in the Specifications section and a description of the emission control system may be found in the appendix to thi...

Page 29: ...placement parts other than those from an authorized service centre will void the warranty Air Index Models certified for sale in California An Air Index Information label is applied to engines certifi...

Page 30: ...d remove the engine access panel Start at the tab and work around the panel This may require some force to loosen the snapfits 2 Unscrew the oil cap and clean the dipstick 3 Add 12 fl Oz 0 35 L Gal of...

Page 31: ...care avoid getting dirt or dust into the engine oil If the oil falls below a safe level the low oil alert system will automatically shut off the engine The low oil light will turn on To avoid the inco...

Page 32: ...lter doing so will quickly degrade the engine 1 Unscrew and remove the engine access panel 2 Unscrew and remove the air filter assembly 3 Remove the foam filter 4 If the foam element is dirty clean it...

Page 33: ...rk plug 1 Remove the spark plug access panel 2 Remove the spark plug cap 3 Remove the spark plug with the spark plug spanner 4 Visually inspect the spark plug Replace with a new one if the insulation...

Page 34: ...er If the spark arrester is worn down replace it 4 Reinstall the spark arrester and muffle guard 7 7 FUEL FILTER MAINTENANCE 1 Remove the fuel cap and filter 2 Clean the filter with solvent 3 Wipe the...

Page 35: ...enerator Drain the generator of fuel and oil before being transported on rough roads 1 Do not overfill the fuel tank there should be no residual fuel on the neck of tank 2 Allow the generator to cool...

Page 36: ...e storage Add fuel stabilizer according to the manufacturer s directions Adding a quality fuel stabilizer can keep gas fresh for up to a year 1 Year or More Drain off the gasoline from the fuel tank a...

Page 37: ...trical appliance for any fault Check the electrical appliance for any fault Is the DC circuit protector OFF Stop the engine and then replace or repair the appliance Repair or replace the appliance Tur...

Page 38: ...power switch in RUN Add the recommended oil Turn the power switch to RUN Clean readjust the gap and dry the spark plug Replace if necessary Is there enough oil in the engine Is the spark plug in good...

Page 39: ...Unleaded Gasoline Oil Capacity 12 fl oz 0 35L Oil Model SAE 10W 30 GENERATOR Model Name eZV2000S Rated Frequency 60Hz Rated Voltage 120V Rated Current 13 3A Rated Output Power 1600W Max Output Power 2...

Page 40: ...33 Working Overload Low oil Magnetor 11 WIRING DIAGRAM...

Page 41: ...rrection 12 APPENDIX The standard condition of rated power output Altitude 0m Ambient temperature 25 C Relative humidity 30 NOTE Relative humidity 60 correction factor C 0 01 Relative humidity 80 corr...

Page 42: ...ct in components or workmanship during the three 3 year period The warranty coverage is continual from the initial date of purchase and does not restart at anytime under any circumstances This limited...

Page 43: ...rranty we do not have the obligation to bear any transportation fees of any product to from an authorized Warranty Center Unauthorized alteration installation or any cause other than defects in materi...

Page 44: ...designed built and equipped to meet the State s stringent anti smog standards Other States U S territories and Canada In other areas of the United States and in Canada your engine must be designed bui...

Page 45: ...ture sensor Engine control module Fuel regulator Intake manifold Evaporative Fuel Tank Fuel Cap Fuel Hoses Vapor Hoses Carbon Canister Canister Mounting Brackets Fuel Strainer Fuel cock Fuel Pump Fuel...

Page 46: ...red for product support and warranty coverage You can register online at www energizergenerators com Once your registration is complete your receipt will be on file and any future warranty claims can...

Page 47: ...40 Enjoy Be sure to check energizergenerators com for updates regarding your generator...

Page 48: ......

Reviews: