ECO-NOMIC
TECHNICAL MANUAL
9
3.2.
Technical Features
*The amount of fluid must be checked by the installer. In some cases, it is necessary to add or remove refrigerant in order
to ensure the correct operation of the system.
**According EN 16147, Commission Delegated Regulation (EU) No. 812/2013 and No. 814/2013 for the three climate
zones: Colder (2 ºC), Average (7 ºC), Warmer (14 ºC)
Un.
250i
HO
T
W
A
TER
CYLINDE
R
Dry Weight
Kg
102
Capacity
l
250
Internal Protection
-
Stainless Steel AISI444
Cathodic Protection
-
Magnesium Anode
(1”1/4 F)
H
yd
rau
lic
Jo
in
ts
Water
–
Inlet and Outlet
Pol.
3/4” Male
TP Valve
1/2” Female
Recirculation
3/4” Male
Insulation
-
High Density Polyurethane
50mm
Maximum Allowed Pressure
bar
7
Maximum Allowed Temperature
°C
80
Heat Loss (EN 12897)
kWh/24h
1,01
TH
ER
M
O
D
YN
A
M
IC
SO
LA
R
P
A
N
EL
Material
-
Solokote Anodized Aluminium
Dimensions (L x W x H)
mm
2000 x 800 x 20
Weigh
kg
8
Max Working Pressure
bar
12
Exposure Temperature(Min|Max)
°C
-40 | 120
TH
ER
M
OD
YN
A
M
IC
B
LOCK
Absorbed Power (Med|Max)
W
390 | 550
Thermal Power
(Med|Max)
W
1690 | 2900
Electrical Backup Power
W
1500
Refrigerant / Qt.*
- / g
R134a / 1100*
Piping Material
-
Copper
(DHP ISO1337)
Refrigerant connections (Liq. |
Asp.)
pol.
1/
4” | 3/8”
Power Supply
V / Hz
220-240 / 50 / Single phase
Running Temperature (Min|Max)
°C
- 5 | 45
PER
FO
R
M
A
NCE
**
Load Profile
-
XL
COP
Air 2
o
C
-
2,9
Air 7
o
C
-
3,3
Air 14
o
C
-
3,7
Energy Efficiency
Class
Air 2
o
C
-
A
Air 7
o
C
-
A+
Air 14
o
C
-
A+
Energy Efficiency
Air 2
o
C
%
119
Air 7
o
C
%
137
Air 14
o
C
%
151
Annual
Energy
Consumption
Air 2
o
C
kWh/y
1411
Air 7
o
C
kWh/y
1287
Air 14
o
C
kWh/y
1111
Amount of Useful Water at 40 oC
l
389
Factory Setpoint
o
C
53
Sound Power Level Indoor
dB
51